Table 1 outlines the customer-supplied components required for the Seakeeper 6 / 5 installation:
Item | Description | QTY | Installation Manual Reference Section | Other Reference | System |
1 | Spreader bar for lifting the Seakeeper | 1 | Transport & Unpacking | P/N 80067 | Mechanical |
2 | Seakeeper 6 Fixture Kit | 1 | Bolt-In Installation | P/N 90392 | Mechanical |
3 | Threaded insert M16-2 (24 mm) | 16 | Bolt-In Installation | Dwg 90398 | Mechanical |
4 | Seakeeper 6/5 Bolt-In Kit | 1 | Bolt-In Installation | P/N 90400 | Mechanical |
5 | Seakeeper 6/5 Thru-Bolt Kit | 1 | Bolt-In Installation | P/N 90660 | Mechanical |
6 | Marine Sealant | AR | Bolt-In Installation | Dwg 90398 | Mechanical |
7 | Nickel-based Anti-seize | AR | Bolt-In Installation | Dwg 90398 | Mechanical |
8 | Circuit Breaker 30 A, 110 VAC or Circuit Breaker 20 A, 230 VAC | 1 | Electrical Equipment Power Connections | Dwg 90396 | Electrical |
9 | Circuit Breaker, 12 VDC, 15 A | 2 | Electrical Equipment Power Connections | Dwg 90396 | Electrical |
10 | Battery Isolator Switch | 1 | Electrical Equipment Power Connections | Dwg 90396 | Electrical |
11 | M6 terminal lug for grounding Seakeeper | 1 | Electrical Equipment Ground Connections | Dwg 90396 | Electrical |
12 | Cable, 10 AWG, for grounding Seakeeper at rear brace to vessel ground | 1 | Electrical Equipment Ground Connections | Dwg 90396 ABYC E-11 | Electrical |
13 | Seawater pump, 12VDC, 15 A max Optional: DC Seawater Pump Assembly (pre-wired) | 1 | Electrical Equipment Power Connections | Dwg 90396 P/N 30331 | Electrical / Cooling |
14 | Compatible MFD or Optional Seakeeper 5″ Touch Display | 1 | Electrical Equipment Power Connections | Dwg 90396 TB-90640 / P/N 90600 | Electrical |
15 | Through-hull fittings (1 high-speed pick-up / 1 overboard discharge) | 2 | Connecting Seawater to Heat Exchanger | Dwg 90397 | Cooling |
16 | Seawater Strainer *included with Seakeeper Seawater Pump (P/N 30331) | 1 | Connecting Seawater to Heat Exchanger | Dwg 90397 | Cooling |
17 | Seacock Valve | 1 | Connecting Seawater to Heat Exchanger | Dwg 90397 | Cooling |
18 | 3/4 in. (19 mm) ID Seawater Suction Hose AND Discharge Hose | AR | Connecting Seawater to Heat Exchanger | Dwg 90397 | Cooling |
19 | Hose clamps for seawater plumbing to ¾ in. (19 mm) hose barb (2 per hose barb) | 4 | Connecting Seawater to Heat Exchanger | Dwg 90397 | Cooling |
AR = As Required
Dwg = Drawing
5.3 Tools Required for Installation
Item | Description | Use |
1 | Wire Cutter | DC and AC power cables |
2 | Wire Stripper | DC and AC power cables |
3 | 10 and 13 mm Socket Wrench | Side Panels and ground stud |
4 | Slot Screwdriver, 5/64 in. | Field assembly connectors |
5 | 1/4 in. Nut Driver | Hose clamps |
6 | Greenlee K05-Synchro Crimp Tool, or equivalent | Ground cable |
7 | Utility Knife | Scoring cable jackets |
8 | Hoist, Forklift, or Crane | Unpacking and Lifting Seakeeper 4.5 into position |
9 | Drill/Drill Press | Bolt hole penetrations |
10 | 1/2 in. Drive Torque Wrench | Foundation bolt torqueing |
11 | 19 mm Socket Wrench | Foundation bolts |
12 | Heat Gun | For conductor heat shrink |
13 | Hole Saw | Through-hull seawater fittings |