2.4.2 Transfer of Holes to Boat Structure

  1. Lower assembled fixture onto hull structure.
  2. The four areas where the feet of the Seakeeper will rest should be coplanar to within .06 in. (1.5 mm). See figure below.
  3. Align fixture in desired location and transfer holes from fixture plate to the foundation structure. Note that holes in fixture plate are ø0.487 in. (12 mm). A transfer punch is supplied with installation template kit, P/N 90392.

Figure 8 Bolt-In Hole Transfer Fixture

2.4.2.1 Blind Hole Installation

  1. Remove Template Fixture and drill sixteen(16) 0.49 in. (12.5 mm) holes perpendicular to the vessel structure to a minimum depth of 0.94 in. (24 mm). Take special care to drill perpendicular to mounting surface. A drill guide is recommended. Remove any impeding obstructions.
  2. Tap drilled holes for helical thread inserts per documentation accompanying helical threaded inserts.
  3. Install sixteen (16) M12-1.75 X 18 mm threaded inserts into holes in hull structure at drilled and tapped locations using threaded insert manufacturer provided installation tool.
  4. Remove threaded insert prong / tang after threaded inserts are installed.
Example threaded insert
M12-1.75 X 18 mm

2.4.2.2 Through-Bolt Installation

  1. Remove Template Fixture and drill sixteen (16) 0.512 in. (13 mm) ø holes perpendicular to the vessel structure. Take special care to drill perpendicular to mounting surface. A drill guide is recommended.