5.2 Supplies Required for Installation

(Not Supplied With the Seakeeper)

ItemDescriptionQtyInstallation Manual Reference SectionOther ReferenceSystem
1Soundproofing ConsiderationsSelection of Installation LocationMechanical
2Spreader bar for lifting the Seakeeper1Transport and UnpackingMechanical
3Seakeeper 2 Fixture Kit1Bolt-In InstallationP/N 90473Mechanical
4Hose clamps for seawater plumbing to ¾ in. (19 mm) hose barb (2 per hose barb)4Connecting Seawater to Heat ExchangerDwg 90490Cooling
53/4 in. (19 mm) ID HoseARConnecting Seawater to Heat ExchangerDwg 90490Cooling
6Seacock Valve1Connecting Seawater to Heat ExchangerDwg 90490Cooling
7Seawater Strainer (included with Seakeeper Seawater Pump (P/N 30331))1Connecting Seawater to Heat ExchangerDwg 90490Cooling
8Through-Hull Fittings (1 high speed pick up and 1 overboard discharge)2Connecting Seawater to Heat ExchangerDwg 90490Cooling
9M6 terminal lug for grounding Seakeeper at rear brace1Electrical Equipment Ground Connections Dwg 90470 Electrical
10Cable, 4 AWG, for grounding Seakeeper at foundation to vessel ground (used with item 5)ARElectrical Equipment Ground Connections Dwg 90470Electrical
11Seawater pump, 12 VDC, 15A max1Electrical Equipment DC Pump Power Dwg 90470 Electrical
12100 A Circuit breaker for Conductor 11Electrical Equipment High Current Power Input Dwg 90470 Electrical
1315 A Circuit breaker for Low Current Power and DC Seawater Pump2Electrical Equipment Low Current Power Input Dwg 90470 Electrical
14Battery Isolator Switch1Electrical Equipment Power ConnectionsDwg 90470Electrical
15Marine SealantARBolt-In InstallationDWG 90487Mechanical
16Nickel-based Anti-SeizeARBolt-In InstallationDWG 90487Mechanical

AR = As Required
Dwg = Drawing