4.4 Seakeeper Optional DC Seawater Pump

  1. Seakeeper offers a self-priming DC Seawater pump as an optional addition, P/N 30331 – DC Seawater Pump Assembly, shown in Figure 26.
  2. The Seakeeper Seawater Pump is a 24 VDC pump operated at 12 VDC for the Seakeeper 2 and maintains a seawater flow of approximately 2.5 GPM (9.5 LPM) at 12 VDC.
  3. The pump assembly is pre-wired for connection to Seakeeper 2 Cable 5 and includes a seawater strainer and various fittings. The pump specifications are as follows:

NOTE: Use only SeaFlo-provided threaded fittings for DC Seawater Pump 30331.

Volts24 VDC (intended for 12 VDC operation with Seakeeper 2)
Flowrate2.5 GPM (9.5 LPM), at 12 VDC
Overcurrent Protection Rating15 A
Ignition Protection RatingISO 8846 or equivalent
Figure 26 Seakeeper DC Seawater Pump Assembly (P/N 30331)