Seakeeper 2 Installation Manual (90488-4); S/N 2-232-1564 to Current
3.3 Electrical Equipment Ground Connections
Seakeeper to Vessel Ground Connection Instructions
- Connect the Seakeeper foundation ground stud, shown in Figure 18, to vessel ground.
- Install Ground Wire (4 AWG or 25 mm2, Customer Supplied) from the M6 brass ground stud to vessel grounding bus to comply with:
- EM / IEC 60204-1 Clauses 6.3.3 and 8.2.3.
- ABYC E-11 July 2018 Clauses 11.5.2 and 11.16.1.
- Install Ground Wire (4 AWG or 25 mm2, Customer Supplied) from the M6 brass ground stud to vessel grounding bus to comply with:
NOTE: ONLY USE THIS LOCATION FOR GROUNDING THE SEAKEEPER TO THE VESSEL GROUND.
b. A proper ground connection is critically important for corrosion
protection and helps to ensure the ignition protection of the unit
by ensuring it does not carry any stray current.
c. NOTE: the ground is not referring specifically to a bonding system
but for outboard boats generally refers to the outboard engine
negative terminal, or its bus, to the DC grounding bus. This connection
shall be used only as a means of maintaining the negative side of the
circuit at ground potential and is not to carry current under normal
operating conditions. See Figure 19.