3.2.2 Low Current 12 V Power Input

Low Current 12 VDC Power Source Requirements

SourceBattery Bank, 12 VDC, Marine, Deep Cycle
Alternate SourcePower Supply / Battery Charger, 12 VDC
Voltage Range11 – 15 VDC
Continuous Current9 A
Overcurrent Protection15 A (Customer Supplied)

Low Current 12 VDC Power Connection Instructions



Reversing polarity on the DC power input to the Seakeeper can result in damaging the electronics in the control system.

  1. Install Seakeeper-provided Low Current DC Power Input Cable, (P/N 20248) to battery bank.
  2. Connect control power positive conductor (B+, red) through dedicated over-current protection device (customer supplied) and a dedicated Seakeeper isolation switch (customer supplied). A 2AWG, B+ conductor (red), is capable of carrying the current for both the High Current, Low Current, and Seawater Pump from the 12VDC power supply to the dedicated battery isolation switch.
  3. Connect negative conductor (B-, black) directly to battery minus terminal or negative DC bus bar.
  4. Before connecting Low Current Power Cable to Seakeeper, check for proper voltage and polarity with a DC multimeter using Figure 14 below.

When energizing DC power the first time, if display does not power up immediately then disconnect and inspect connector polarity.

Figure 14 – Low Current 12 VDC Power Input Connector Contact Assignments (Front)
  1. Connect low-current control power cable to Low Current 12 VDC power input connector on the Seakeeper, Deutsch DTP04-2P connector.