Seakeeper 2 Installation Manual (90488-4); S/N 2-232-1564 to Current
5.2 Supplies Required for Installation
(Not Supplied With the Seakeeper)
Item | Description | Qty | Installation Manual Reference Section | Other Reference | System |
---|---|---|---|---|---|
1 | Soundproofing Considerations | Selection of Installation Location | Mechanical | ||
2 | Spreader bar for lifting the Seakeeper | 1 | Transport and Unpacking | Mechanical | |
3 | Seakeeper 2 Fixture Kit | 1 | Bolt-In Installation | P/N 90473 | Mechanical |
4 | Hose clamps for seawater plumbing to ¾ in. (19 mm) hose barb (2 per hose barb) | 4 | Connecting Seawater to Heat Exchanger | Dwg 90490 | Cooling |
5 | 3/4 in. (19 mm) ID Hose | AR | Connecting Seawater to Heat Exchanger | Dwg 90490 | Cooling |
6 | Seacock Valve | 1 | Connecting Seawater to Heat Exchanger | Dwg 90490 | Cooling |
7 | Seawater Strainer (included with Seakeeper Seawater Pump (P/N 30331)) | 1 | Connecting Seawater to Heat Exchanger | Dwg 90490 | Cooling |
8 | Through-Hull Fittings (1 high speed pick up and 1 overboard discharge) | 2 | Connecting Seawater to Heat Exchanger | Dwg 90490 | Cooling |
9 | M6 terminal lug for grounding Seakeeper at rear brace | 1 | Electrical Equipment Ground Connections | Dwg 90470 | Electrical |
10 | Cable, 4 AWG, for grounding Seakeeper at foundation to vessel ground (used with item 5) | AR | Electrical Equipment Ground Connections | Dwg 90470 | Electrical |
11 | Seawater pump, 12 VDC, 15A max | 1 | Electrical Equipment DC Pump Power | Dwg 90470 | Electrical |
12 | 100 A Circuit breaker for Conductor 1 | 1 | Electrical Equipment High Current Power Input | Dwg 90470 | Electrical |
13 | 15 A Circuit breaker for Low Current Power and DC Seawater Pump | 2 | Electrical Equipment Low Current Power Input | Dwg 90470 | Electrical |
14 | Battery Isolator Switch | 1 | Electrical Equipment Power Connections | Dwg 90470 | Electrical |
15 | Marine Sealant | AR | Bolt-In Installation | DWG 90487 | Mechanical |
16 | Nickel-based Anti-Seize | AR | Bolt-In Installation | DWG 90487 | Mechanical |
AR = As Required
Dwg = Drawing