4.1 Cooling Installation Introduction
The Seakeeper 26 is shipped with the cooling circuit filled and ready for use. Only a quick confirmation of glycol level is required.
Reference Documents & Drawings:
- 90244 – Seakeeper 26 Hardware Scope of Supply
- 90310 – Seakeeper 26 Cable Block Diagram
- 90320 – Seakeeper 26 Cooling Water Schematic
- TB-90947 – Seawater Plumbing Best Practices
The Seakeeper 26 is shipped with the cooling circuit filled and ready for use. The Seakeeper 26 requires connection to a raw water pump, referred to as the seawater pump, to cool the closed loop glycol cooling circuit on the unit. The required seawater flow through the Seakeeper 26 heat exchanger is between 4 – 8 GPM (15.1 – 30.3 LPM) when the on-demand cooling system requires cooling. Prior to operation, confirmation of glycol level is recommended.