Seakeeper 5 / 6 Installation Manual (90402-4) 6/5-222-5365 to 6/5-233-5846
4.3 Connecting Seawater to Heat Exchanger
4.3.2 Connecting Seawater to Heat Exchanger
Refer to Figure 4 for typical seawater plumbing arrangement.

- Connect seawater pump to Seakeeper dedicated through-hull fitting. A strainer and seacock valve should generally be installed between the seawater inlet and the pump.
- Connect seawater from installer-supplied pump to lower ¾ in. (19 mm) hose barb on heat exchanger. Use the same practices as other below waterline seawater plumbing. Required flow rate is 2.5 GPM (9.5 LPM) minimum and 8 GPM (30.3 LPM) maximum.
- Connect seawater discharge (upper hose barb) to overboard drain. Use the same practices as other below waterline seawater plumbing.
- In addition to initial operation at dock, new installations should be checked for minimum 2.5 GPM (9.5 LPM) flow while vessel is at speed and when backing down.
- If no other method of confirming flow is available, discharge line may be temporarily diverted to a bucket. Flow is calculated from time to fill a known volume.
- A self-priming seawater pump (customer/installer supplied) may be required due to installation location to maintain water flow in all underway conditions where cavitation may occur and potentially cause an air-lock condition restricting seawater flow to the heat exchanger.
- Inspect raw water plumbing after sea trial for any signs of leakage.
- Heat exchanger contains removable end-caps to provide access for cleaning the tube bundle.
4.3.3 Seakeeper Optional DC Seawater Pump (P/N 30331)
- Seakeeper offers a self-priming DC Seawater pump as an optional addition, P/N 30331– DC Seawater Pump Assembly, shown in Figure 6.
- The Seakeeper Seawater Pump is a 24 VDC pump operated at 12 VDC for the Seakeeper 6.
- The pump assembly is pre-wired for connection to Seakeeper 6 Cable 5 and includes a seawater strainer and various fittings. The pump specifications are as follows:
Volts | 24 VDC (operate at 12 V for Seakeeper 6) |
Rated Flow | 2.5 – 8 GPM (9.5 – 30.3 LPM) |
Overcurrent Protection Rating | 15 A |
Ignition Protection | ISO 8846 or equivalent |

NOTE: Use only SeaFlo-provided threaded fittings for DC Seawater Pump 30331.