Seakeeper 40 Installation Manual (90715-2) 40-234-0043 - 40-244-0120
2.4.2 Transfer of Holes to Boat Structure
- Lower assembled fixture onto hull structure.
- The four areas where the isolation mounts will rest should be coplanar to within 0.13 in. (3 mm). See figure below. Do not use the fixture to check co-planarity as it is not stiff enough.
- Align fixture in desired location and transfer holes from fixture plate to the hull structure. A transfer punch is recommended for this step. Note that holes in fixture plate are 0.257 in. (6.5 mm) in diameter.
- Remove fixture and drill holes in hull structure at marked locations to mate with holes in Seakeeper isolation mounts. A 0.689 in. (17.5 mm) diameter hole is recommended for the provided M16 fasteners.
NOTE: Certain foundation designs that employ threaded blind holes in thick plates may require the installer to obtain alternate fasteners.