Seakeeper 4 / 4.5 Installation Manual (90762-1)
5.0 Installation Requirements
5.1 Installation Requirements Introduction
The Installation Requirements section outlines the components and tools needed for the Seakeeper 4 / 4.5 installation that are not included within the scope of supply.
5.2 Required Supplies for Installation
Table 1 outlines the customer-supplied components required for the Seakeeper 4.5 installation. Part numbers are provided for items available through Seakeeper.
TABLE 1: Items not provided by Seakeeper
Item | Description | Qty | Manual Reference | Other Reference | System |
1 | Spreader Bar for lifting Seakeeper | 1 | Transport & Unpacking | P/N 11766 | Mechanical |
2 | Seakeeper 4.5 Installation Fixture | 1 | Mechanical Installation | Dwg 90XXX | Mechanical |
3 | Threaded insert: Mxx-x X xx Dia (xx mm) | 8 | Mechanical Installation | Dwg 90726 | Mechanical |
4 | Seakeeper 4.5 Optional Thru-Bolt Kit | 1 | Mechanical Installation | P/N 90XXX | Mechanical |
5 | Marine Sealant | AR | Mechanical Installation | Dwg 90726 | Mechanical |
6 | Nickel-based Anti-Seize | AR | Mechanical Installation | Dwg 90726 | Mechanical |
7 | Soundproofing considerations | AR | Selection of Installation Location | Mechanical | |
8 | Hose Clamps for seawater plumbing (2 per hose barb) | 4 | Connecting Seawater to Heat Exchanger | Cooling | |
9 | Circuit Breaker, AC, 2-pole, (30 A to be used with 110-120 VAC, OR 20 A to be used with 208-230 VAC) | 1 | Electrical Equipment Power Connections | Dwg 90696 | Electrical |
10 | Circuit Breaker, DC, 1-Pole, 15 A | 2 | Electrical Equipment Power Connections | Dwg 90696 | Electrical |
11 | M6 Terminal lug for grounding Seakeeper at rear brace | 1 | Electrical Equipment Ground Connections | Electrical | |
12 | Cable, 10 AWG, for ground | AR | Electrical Equipment Ground Connections | Electrical | |
13 | Seawater Pump, 12 VDC | 1 | Electrical Equipment Power Connections | Electrical |
Dwg = Drawing
TABLE 2
Item | Description | Use |
1 | Wire Cutter | DC and AC power cables |
2 | Wire Stripper | DC and AC power cables |
3 | 10 and 13 mm Socket Wrench | Cover Panels and ground stud |
4 | Slot Screwdriver, 5/64 in. | Field assembly connectors |
5 | 1/4 in. Nut Driver | Hose clamps |
6 | Terminal or Quick Disconnect Crimper | Power cables |
7 | Utility Knife | Scoring cable jackets |
8 | Hoist, Forklift, or Crane | Unpacking and lifting Seakeeper into position |
9 | Transfer Punch Kit | Locate foundation hole penetrations |
10 | Drill / Drill Press | Bolt hole penetrations |
11 | Threaded Insert Installation Kit | Tap and install threaded inserts for blind hole installations |
12 | 1/2″ Drive Torque Wrench | Foundation mounting screws |
13 | Heat Gun | Cable heat shrink |
14 | Fish Tape | Cable pulls |
15 | Hole Saw | Thru-hull fittings |
5.3 Tools Required for Installation
TABLE 2
Item | Description | Use |
1 | Wire Cutter | DC and AC power cables |
2 | Wire Stripper | DC and AC power cables |
3 | 10 and 13 mm Socket Wrench | Cover Panels and ground stud |
4 | Slot Screwdriver, 5/64 in. | Field assembly connectors |
5 | 1/4 in. Nut Driver | Hose clamps |
6 | Greenlee K05-Synchro Crimp Tool, or equivalent | Ground cable |
7 | Utility Knife | Scoring cable jackets |
8 | Hoist, Forklift, or Crane | Unpacking and Lifting Seakeeper 4.5 into position |
9 | Drill/Drill Press | Bolt hole penetrations |
10 | 1/2 in. Drive Torque Wrench | Foundation bolt torqueing |
11 | 22 mm Socket Wrench | Foundation bolts |
12 | Heat Gun | For conductor heat shrink |
13 | Hole Saw | Through-hull seawater fittings |