Seakeeper 4 / 4.5 Installation Manual (90762-1)
3.4 Seawater Pump Power Connections

Reversing polarity on the DC power input to the Seakeeper can result in damage to electronics in the control system.
DC Seawater Pump Power Source Requirements
- One 12 VDC, 15 A (Customer supplied) for DC Seawater Pump.
- OPTIONAL: Seakeeper 4.5 may use one 24 VDC, 10 A (Customer supplied) source for the DC Seawater Pump.
- A dedicated breaker should be used for each 12 VDC load on the Seakeeper: one breaker for Control Power and one breaker for Seawater Pump power (Drawing No. 90696 and 90699).
- A dedicated breaker should be used for each Seakeeper‘s Control and Seawater Pump power if multiple units installed.
DC Seawater Pump Input Power Connection
- Install Seakeeper provided DC Seawater Pump Input Cable, P/N 30327 (as shown in Drawing No. 90696 and 90699).
- Route Seawater Pump Input Cable to DC Power Distribution Panel.
- Terminate 16 AWG positive (B+, Red) conductor through 12 VDC dedicated overcurrent protection device (customer supplied), maximum of 15 A, to dedicated battery isolation switch.
- 24 VDC, 10 max can be used for Seakeeper 4.5 Seawater Pump power.
- Terminate 16 AWG negative (B-, Black) conductor directly to battery negative terminal or DC main negative bus bar.
- Before connecting Seawater Pump Input Cable to Seakeeper wire harness (at “SW PUMP VDC IN”), check for proper voltage and polarity with a multimeter using figure below.

- Connect Seawater Pump Input Cable to “SEAWATER IN” connector on the Seakeeper wire harness Deutsch DT04-2P connector.
DC Seawater Pump Output Power Connection
- Connect Seawater Pump Output cable (P/N 20334) to the Seakeeper 4.5 “SW PUMP VDC OUT” connector.
- The Seawater Pump Output cable is a 2 X 16 AWG cable, 16 ft (5 m) length, with a size 16 female Deutsch plug.
- Pumps rated at 12 VDC, 15 A maximum (24 VDC, 10 A), customer-supplied, must be configured with a Deutsch DT series, 2-pin receptacle to mate with the connector shown in figure below.

- The Seawater Pump Output cable must be routed and installed in the vessel from the Seakeeper “SEAWATER OUT” connector (male) to the DC seawater pump cable Deutsch connector (female).
- Connect Seawater Pump Output cable plug (female) to the customer-supplied receptacle (male). The recommended wiring is shown in figure below.
- Contact Seakeeper if desired to install customer-supplied relay on Seawater Pump Output cable to power Seawater Pump.