5.2 Required Supplies for Seakeeper Installation

Required Supplies Needed for Seakeeper Installation
(Not Supplied With the Seakeeper)

ItemDescriptionQtyInstallation Manual Reference SectionOther ReferenceSystem
1Adhesive and cleaning supplies for bonding to hullMechanical InstallationMechanical
2Soundproofing ConsiderationsSelection of Installation LocationMechanical
3Spreader bar for lifting Seakeeper1Transport and UnpackingP/N 80029Mechanical
4Hose clamps for seawater plumbing to 1 in. (25.4 mm) hose barb (2 per hose barb)4Connecting Seawater to Heat ExchangerCooling
53/4″ to 1″ Hose Adapter1Connecting Seawater to Heat ExchangerCooling
6Circuit Breaker, AC, 2-Pole, 20 A1Electrical Equipment Power ConnectionsDwg 90710Electrical
7Circuit Breaker, DC, 1-Pole,
15 A for control power
1Electrical Equipment Power ConnectionsDwg 90710Electrical
8Circuit Breaker, DC, 1-Pole,
20 A for seawater pump
1Electrical Equipment Power Connections Dwg 90710Electrical
9M6 terminal lug for grounding Seakeeper at rear of foundation1Electrical Equipment Ground ConnectionsElectrical
10Cable, 10 AWG, for grounding Seakeeper at rear brace to vessel ground ARElectrical Equipment Ground Connections Dwg 90710Electrical
11Seawater pump, 24 VDC1Electrical Equipment Power Connections P/N 30490 availableElectrical
12Relay for seawater pump control (Optional)1Electrical Equipment Power Connections Electrical
13Sili-Thane 803 Sealant (or equivalent)ARMechanical InstallationMechanical
14Nickel-based Anti-SeizeARMechanical InstallationMechanical

AR = As Required
Dwg = Drawing