2.3.2 Transfer of Holes to Boat Structure

  1. Lower assembled fixture onto hull structure.
  2. The four areas where the feet of the Seakeeper will rest should be coplanar to within .06 in. (1.5 mm). See Figure 8.
  3. Align fixture (P/N 90362) in desired location and transfer holes from fixture plate to the hull structure.

Note: Holes in fixture plate are ø0.64 in. (16.26 mm).

Figure 8 – Coplanar Requirement
Helical Thread Insert
Installation Fixture

2.3.2.1 Blind Hole Installation

  1. Remove Template Fixture and drill four (4) 0.65 in. (16.5 mm) holes perpendicular to the vessel structure to a minimum depth of 0.94 in. (24 mm). Take special care to drill perpendicular to mounting surface. A drill guide is recommended. Remove any impeding obstructions.
  2. Tap drilled holes for helical thread inserts per documentation accompanying helical threaded inserts. (Tap will be included in thread insert kit.)
  3. Install four (4) M16-2.0 X 24 mm threaded inserts into holes in hull structure at drilled and tapped locations using threaded insert manufacturer provided installation tool.
  4. Remove threaded insert prong / tang after threaded inserts are installed.

2.3.2.2 Through-Hole Installation

  1. Remove Template Fixture and drill four (4) 0.67 in. (17 mm) ø holes perpendicular to the vessel structure.

NOTE: Take special care to drill perpendicular to mounting surface. A drill guide is recommended.