5.2 Required Supplies for Seakeeper Installation

Table 1 outlines the customer-supplied components required for the Seakeeper 3 installation:

Table 1: Components and Supplies Required for Seakeeper 3 Installation

ItemDescriptionQTYInstallation Manual Reference SectionOther ReferenceSystem
1Spreader bar for lifting the Seakeeper1Transport & UnpackingP/N 11766Mechanical
2Seakeeper 3 Fixture Kit1Bolt-In InstallationP/N 90362Mechanical
3Threaded insert M16-2 (24 mm)4Bolt-In InstallationDwg 90374Mechanical
4Seakeeper 3 Bolt-In Kit1Bolt-In InstallationP/N 90375Mechanical
5Seakeeper 3 Thru-Bolt Kit1Bolt-In InstallationP/N 90641Mechanical
6Marine SealantARBolt-In InstallationDwg 90374Mechanical
7Nickel-based Anti-seizeARBolt-In InstallationDwg 90374Mechanical
8Circuit Breaker, 100A
(Cable 1)
1Electrical Equipment Power ConnectionsDwg 90377Electrical
9Circuit Breaker, 15 A
(Cable 7 & 8)
2Electrical Equipment Power ConnectionsDwg 90377Electrical
10Battery Isolator Switch
(Cable 1, 7, & 8)
1Electrical Equipment Power ConnectionsDwg 90377Electrical
11M6 terminal lug for grounding Seakeeper1Electrical Equipment Ground ConnectionsDwg 90377Electrical
12Cable, 4 AWG, for grounding Seakeeper
at rear brace to vessel ground (Cable 6, used with item 11)
1Electrical Equipment Ground ConnectionsDwg 90377
ABYC E-11
Electrical
13Seawater pump, 12VDC, 15 A max Optional: DC Seawater Pump Assembly (pre-wired) 1Electrical Equipment Power ConnectionsDwg 90377
P/N 30331
Electrical / Cooling
14Seakeeper 5″ Touch Display and Optional Compatible MFD1Electrical Equipment Power ConnectionsDwg 90377
TB-90640 / P/N90600
Electrical
15Through-hull fittings (1 high-speed pick-up / 1 overboard discharge)2Connecting Seawater to Heat ExchangerDwg 90376Cooling
16Seawater Strainer *included with Seakeeper Seawater Pump(P/N 30331)1Connecting Seawater to Heat ExchangerDwg 90376Cooling
17Seacock ValveConnecting Seawater to Heat ExchangerDwg 90376Cooling
183/4 in. (19 mm) ID Seawater Suction Hose AND Discharge HoseARConnecting Seawater to Heat ExchangerDwg 90376Cooling
19Hose clamps for seawater plumbing to ¾ in. (19 mm) hose barb (2 per hose barb)4Connecting Seawater to Heat ExchangerDwg 90376Cooling

AR = As Required
Dwg = Drawing