Seakeeper 18 Installation Manual (90672-2); S/N 18-234-2475 to Current
6.0 Installation and Start Up Checklist
6.1 Installation and Start Up Introduction
Reference Documents:
- 90437 – Seakeeper Commissioning Form
- SWI-105 – Commissioning Checklist
- Seakeeper 18 Operation Manual
The Installation and Start Up Checklists in this section provide an overview of the primary steps covered in the installation manual and should be referenced throughout the installation process. Upon completion of the
Seakeeper 18 installation, the installer should commission each Seakeeper unit with the Seakeeper Commissioning Form (90437). The Commissioning Checklist Work Instruction (SWI-105) provides a checklist of items to inspect and verify during the commissioning process and serves as a supplement to the Seakeeper Commissioning Form (90437).
All Seakeeper stabilizers should be commissioned to verify installation specifications and requirements have been implemented properly. The commissioning process should include completion of the Seakeeper
Commissioning Form (90437), all the items in the Installation Checklist, and verification of Seakeeper 18 operation without alarms or abnormal behavior.
Please Complete Checklist and E-mail to support@seakeeper.com
6.2 Installation Checklist
Mechanical Checklist (reference Installation Manual Section 2)
CHECK | ACTION |
Seakeeper foundation installed in hull | |
Foundation bolts torqued to specification |
Electrical Checklist (reference Seakeeper Drawing 90679 & Installation Manual Section 3)
CHECK | ITEM | ACTION |
MOUNT COMPONENTS | ||
![]() | MFD Display or Seakeeper 5″ Touch Display | Connect Ethernet adapter M12 D-Code cable to appropriate MFD ethernet cable. For 5″ Touch Display, install 90600 kit. |
CONNECT CUSTOMER SUPPLIED CABLES | ||
![]() | Ground Cable | Install lugs on both ends of customer supplied 10 AWG ground cable |
![]() | Connect one end of ground cable to nearest vessel ground and other end to Seakeeper rear brace | |
CONNECT SEAKEEPER SUPPLIED CABLES | ||
![]() | DC Control Power Cable | Connect DC power cable from Seakeeper to 24 VDC power at customer supplied connection box or directly to circuit breaker |
![]() | Plug connector of DC Input Power Cable into mating connector on Seakeeper wire harness | |
![]() | AC Power Cable | Connect AC power cable from Drive Box to 230 VAC single phase at customer supplied connection box or directly to circuit breaker |
![]() | NMEA 2000 CAN Communications Cable | Connect NMEA 2000 Drop Cable to backbone |
![]() | DC Seawater Output Cable | Connect DC Seawater Pump Output Power Cable Male-Female connection to the DC “Seawater Pump-Out” from the Wire Harness |
![]() | DC Seawater Input Cable | Connect DC Seawater Pump Input Power Cable, Female Only connection to the DC “Seawater Pump-In” from the Wire Harness Stripped end to be connected to a 24VDC power source |
Cooling Checklist (reference Installation Manual Section 4)
CHECK | ACTION |
![]() | Verify coolant level in heat exchanger coolant reservoir. |
![]() | Connect seawater hoses / open sea cocks to heat exchanger and test seawater pump. |
![]() | Verify 4 GPM (15 LPM) minimum and 8 GPM (30 LPM) maximum seawater flow through heat exchanger under all operating conditions of the boat. |
Startup Checklist (reference Installation Manual Section 6 & Operation Manual)
CHECK | ACTION |
![]() | Remove lifting eye-bolts and install cover panels |
![]() | Turn on Seakeeper, 24 VDC circuit breaker |
![]() | Turn on Seawater pump, 24 VDC circuit breaker |
![]() | Turn on 230 VAC circuit breaker |
![]() | Verify display works and no ALARMS are present |
![]() | Follow instructions in Seakeeper 18 Operation Manual to turn on the Seakeeper |
![]() | Verify seawater pump turns on when the Seakeeper is turned ON |
![]() | Verify that no ALARMS are present |
![]() | Follow instruction in Seakeeper 18 Operation Manual to turn off the Seakeeper |
![]() | The Seakeeper is powered off by switching off the AC & DC power and seawater pump. The Seakeeper will automatically be in LOCK mode once the system is turned off |
![]() | Seakeeper 18 takes 4.5+ hours to coast down to 0 RPM from full speed |
6.3 Start Up Checklist
Startup Checklist (reference Installation Manual Section 4 & Operation Manual Sec. 2)
CHECK | ACTION |
![]() | Remove lifting eye-bolts and install cover panels |
![]() | Turn on Seakeeper, 24 VDC circuit breaker |
![]() | Turn on Seawater pump, 24 VDC circuit breaker |
![]() | Turn on 230 VAC circuit breaker |
![]() | Verify MFD app / 5″ touch display works and no ALARMS are present |
![]() | Follow instructions in Operation Manual to turn on the Seakeeper |
![]() | Verify seawater pump turns on while the Seakeeper is turned ON (It will run only as needed) |
![]() | Verify that no ALARMS are present |
![]() | Follow instruction in Section 4.1 of Installation Manual to turn off the Seakeeper |
![]() | The Seakeeper is powered off by switching off the AC & DC power and seawater pump. The Seakeeper will automatically be in LOCK mode once the system is turned off |
![]() | Seakeeper 18 takes 4.5+ hours to coast down to 0 RPM from full speed |