2.3.2 Transfer of Holes to Boat Structure

  1. Lower assembled fixture onto hull structure.
  2. The four areas where the feet of the Seakeeper will rest should be coplanar to within 0.06 in. (1.5 mm). See Figure 11 below.
  3. Align fixture in desired location and transfer holes from fixture plate to the foundation structure. Note that holes in fixture plate are ø0.630 in. (16 mm). A transfer punch is supplied with installation template kit, P/N 90995.

Figure 11 – Bolt-In Hole Transfer Fixture

2.3.2.1 Blind Hole Installation

These steps are for affixing tapping plates in the stringers. See drawing 90998 for details:

  1. Remove Template Fixture and drill eight (8) 0.650 in. (16.5 mm) holes perpendicular to the vessel structure to a minimum depth of 1.28 in. (32.5 mm). Take special care to drill perpendicular to mounting surface. A drill guide is recommended. Remove any impeding obstructions.
  2. Tap drilled holes for helical thread inserts (Fig. 12) per documentation accompanying helical threaded inserts (installer-supplied).
  3. Install eight (8) M16-2.0 X 24 mm threaded inserts into holes in hull structure at drilled and tapped locations using threaded insert manufacturer provided installation tool.
  4. Remove threaded insert prong / tang after threaded inserts are installed.
Figure 12 – Example threaded insert
M16-2.0 X 24 mm

2.3.2.2 Through-Bolt Installation

  1. Remove Template Fixture and drill eight (8) 0.670 in. (17 mm) ø holes perpendicular to the vessel structure. Take special care to drill perpendicular to mounting surface. A drill guide is recommended.