Seakeeper 7.5 Installation Manual (90992-1)
5.0 Installation Requirements
5.1 Installation Requirements Introduction
The Installation Requirements section outlines the components and tools needed for the Seakeeper 7.5 installation that are not included within the scope of supply.
5.2 Required Supplies for Seakeeper Installation
Table 1 outlines the customer-supplied components required for the Seakeeper 7.5 installation:
| Item | Description | QTY | Installation Manual Reference Section | Other Reference | System |
| 1 | Spreader bar for lifting the Seakeeper | 1 | Transport & Unpacking | P/N 81885 | Mechanical |
| 2 | Seakeeper 7.5 Fixture Kit | 1 | Bolt-In Installation | P/N 90995 | Mechanical |
| 3 | Threaded insert M16-2 (24 mm) | 8 | Bolt-In Installation | Dwg 90998 | Mechanical |
| 4 | Seakeeper 7.5 Bolt-In Kit | 1 | Bolt-In Installation | P/N 90911 | Mechanical |
| 5 | Seakeeper 7.5 Thru-Bolt Kit | 1 | Bolt-In Installation | P/N 90912 | Mechanical |
| 6 | Marine Sealant | AR | Bolt-In Installation | Dwg 90998 | Mechanical |
| 7 | Nickel-based Anti-seize | AR | Bolt-In Installation | Dwg 90998 | Mechanical |
| 8 | Circuit Breaker 30 A, 110 VAC or Circuit Breaker 30 A, 230 VAC | 1 | Electrical Equipment Power Connections | Dwg 90951 | Electrical |
| 9 | Circuit Breaker, 12 VDC, 15 A | 2 | Electrical Equipment Power Connections | Dwg 90951 | Electrical |
| 10 | Battery Isolator Switch | 1 | Electrical Equipment Power Connections | Dwg 90951 | Electrical |
| 11 | M6 terminal lug for grounding Seakeeper | 1 | Electrical Equipment Ground Connections | Dwg 90951 | Electrical |
| 12 | Cable, 10 AWG, for grounding Seakeeper at rear brace to vessel ground | 1 | Electrical Equipment Ground Connections | Dwg 90951 ABYC E-11 | Electrical |
| 13 | Seawater pump, 12VDC, 15 A max Optional: DC Seawater Pump Assembly (pre-wired) | 1 | Electrical Equipment Power Connections | Dwg 90951 P/N 30685 | Electrical / Cooling |
| 14 | Compatible MFD | 1 | Electrical Equipment Power Connections | Dwg 90951 | Electrical |
| 15 | Through-hull fittings (1 high-speed pick-up / 1 overboard discharge) | 2 | Connecting Seawater to Heat Exchanger | Dwg 90952 | Cooling |
| 16 | Seawater Strainer *included with Seakeeper Seawater Pump (P/N 30685) | 1 | Connecting Seawater to Heat Exchanger | Dwg 90952 | Cooling |
| 17 | Seacock Valve | 1 | Connecting Seawater to Heat Exchanger | Dwg 90952 | Cooling |
| 18 | 3/4 in. (19 mm) ID Seawater Suction Hose AND Discharge Hose | AR | Connecting Seawater to Heat Exchanger | Dwg 90952 | Cooling |
| 19 | Hose clamps for seawater plumbing to ¾ in. (19 mm) hose barb (2 per hose barb) | AR | Connecting Seawater to Heat Exchanger | Dwg 90952 | Cooling |
AR = As Required
Dwg = Drawing
5.3 Tools Required for Installation
| Item | Description | Use |
| 1 | Wire Cutter | DC and AC power cables |
| 2 | Wire Stripper | DC and AC power cables |
| 3 | 10 and 13 mm Socket Wrench | Side Panels and ground stud |
| 4 | Slot Screwdriver, 5/64 in. | Field assembly connectors |
| 5 | 1/4 in. Nut Driver | Hose clamps |
| 6 | Greenlee K05-Synchro Crimp Tool, or equivalent | Ground cable |
| 7 | Utility Knife | Scoring cable jackets |
| 8 | Hoist, Forklift, or Crane | Unpacking and Lifting Seakeeper 7.5 into position |
| 9 | Drill/Drill Press | Bolt hole penetrations |
| 10 | 1/2 in. Drive Torque Wrench | Foundation bolt torqueing |
| 11 | 19 mm Socket Wrench | Foundation bolts |
| 12 | Heat Gun | For conductor heat shrink |
| 13 | Hole Saw | Through-hull seawater fittings |