Specifications and Summary

Seakeeper 2
Rated RPM9,000 RPM
Angular Momentum at Rated RPM2,000 N-m-s
Anti-Rolling Torque at Rated RPM5,249 N-m
Spool-up Time to Rated Speed35 minutes (9,000 RPM)
Spool-up Time to Stabilization 24 minutes (7,650 RPM)
Spool-up Power
DC Motor
850 Watts Max
Operating Power
DC (Sea state dependent)
300-650 Watts
Voltage
DC Input
12 VDC @ 85 Amps (Spool-up)
Seawater Supply to Heat Exchanger2 GPM (7.6 LPM) minimum
6 GPM (22.7 LPM) maximum
Ambient Air Temperature32˚ – 140˚F (0 – 60˚C)
Weight414 lbs (188 kg)
Envelope Dimensions24.8 L x 25.5 W x 20 H (inches)
0.63 L x 0.648 W x 0.508 H (meters)
Noise Output< 68 dBC at 1 meter

Arrangement
The Seakeeper 2 consists of the Flywheel, Enclosure, Foundation, Electronics, Brake, Cooling, and Cover Subsystems.

Installation Location
The Seakeeper is a torque device and does not have to be installed in a specific hull location or on the centerline. However, the Seakeeper should not be installed forward of the longitudinal center of gravity to minimize high acceleration loading due to hull/wave impacts during operation at high speed or in large waves.

Mounting Dimensions
See Drawing No. 90487 – Seakeeper 3 Bolt-In Installation Details.

Loads
The installer is responsible for designing the foundation to which the Seakeeper is attached and for ensuring that this foundation can safely transfer the concentrated Seakeeper loads from the frame to the adjacent hull structure. Loads that the Seakeeper imposes on the hull structure are explained on Drawing No. 90487 –
Seakeeper 2 Bolt-In Installation Details; these loads do NOT include vessel motion accelerations, such as vertical slam loads which can be high for higher speed vessels.

Cooling
The Seakeeper bearings, Motor Drive Box, and hydraulic manifold are cooled by a closed water / glycol mix cooling loop that incorporates a seawater heat exchanger. The installer is responsible for providing 2 – 6 GPM (8 – 22 LPM) raw water at ambient sea temperature and a maximum pressure of 20 psi (1.4 bar) to the heat exchanger.

Electrical
The installer is responsible for supplying 12 VDC at 100 A service to the Motor Drive Box and12 VDC at 15 A service to the Seakeeper Control System. Separate circuit breakers should be used for each Motor Drive Box in multiple Seakeeper installations. Similarly, separate circuit breakers should be used for each Seakeeper
Control System in multiple Seakeeper installations.

Operator Controls
A Touchscreen Display is used to start, operate, monitor, and shutdown the Seakeeper.

Performance
Reduction of boat roll is a function of the boat’s displacement, transverse metacentric height (GMT) and hull damping as well as the operating conditions (speed and heading with respect to waves) and sea state. The
Seakeeper controller regulates the active hydraulic brake to ensure the Seakeeper’s anti-roll torque is maximized regardless of hull characteristics or operating conditions.

Alarm and Monitoring
Sensors, alarms and shutdowns are provided to allow unattended operation. Sensors measure Seakeeper
and drive temperatures, vacuum pressure, gimbal angle, brake pressure, and ship motion. The Seakeeper
controller sends sensor values and alarm information to the display and also locks the brake and shuts down the motor drive in the event of an alarm condition. Seakeeper operating history during faults or alarms is recorded in the controller’s memory for subsequent recall if service is needed. Seakeeper may access the Seakeeper’s software to gather run hours, bearing loading, and hull slamming information.

Safety
The brake automatically locks the Seakeeper so it cannot generate excessive anti-rolling torque loads in the event of a system fault or alarm, loss of electrical power or loss of brake pressure. The brake can be locked from the Display or by shutting off AC and DC power at the supply breakers.