5.2 Required Supplies for Installation

Table 1 outlines the customer-supplied components required for the Seakeeper 5 installation. Part numbers are provided for items available through Seakeeper.

TABLE 1: Items not provided by Seakeeper

ItemDescriptionQtyManual ReferenceOther ReferenceSystem
1Spreader Bar for lifting Seakeeper1Transport & UnpackingP/N 11766Mechanical
2Seakeeper 5 Installation Fixture1Mechanical InstallationDwg 90819Mechanical
3Threaded insert: M16-2.0
(Blind-bolt only into tapping plate)
8Mechanical InstallationDwg 90726Mechanical
4Seakeeper 5 Thru-Bolt Kit (Optional)1Mechanical InstallationP/N 90805Mechanical
5Marine SealantARMechanical InstallationDwg 90726Mechanical
6Nickel-based Anti-SeizeARMechanical InstallationDwg 90726Mechanical
7Soundproofing considerationsARSelection of Installation LocationMechanical
8Circuit Breaker, AC, 2-pole, (30 A to be used with 110-120 VAC, OR 20 A to be used with 208-230 VAC)1Electrical Equipment Power ConnectionsDwg 90982Electrical
9Circuit Breaker, DC, 1-Pole, 15 A2Electrical Equipment Power ConnectionsDwg 90982Electrical
10M6 Terminal lug for grounding Seakeeper at rear brace1Electrical Equipment Ground ConnectionsDwg 90982Electrical
11Cable, 10 AWG, for groundARElectrical Equipment Ground ConnectionsDwg 90982Electrical
12Seawater Pump, 12 VDC1Electrical Equipment Power ConnectionsDwg 90982 Dwg 90948
Dwg 30331
Electrical & Cooling
13Through-hull fittings (1 high-speed pick-up / 1 overboard discharge)2Connecting Seawater to Heat ExchangerDwg 90948Cooling
14Seawater Strainer *included with Seakeeper Seawater Pump (P/N 30331)1Connecting Seawater to Heat ExchangerDwg 90948 Dwg 30331Cooling
15Seacock Valve1Connecting Seawater to Heat ExchangerDwg 90948Cooling
163/4 in. (19 mm) ID Seawater Suction Hose AND Discharge HoseARConnecting Seawater to Heat ExchangerDwg 90948Cooling
17Hose clamps for seawater plumbing to ¾ in. (19 mm) hose barb (2 per hose barb)Connecting Seawater to Heat ExchangerDwg 90948Cooling
AR = As Required
Dwg = Drawing