7.0 Specifications and Summary

Seakeeper 6Seakeeper 5
Rated RPM9,700 RPM8,100 RPM
Angular Momentum at Rated RPM6,000 N-m-s5,000 N-m-s
Anti-Rolling Torque at Rated RPM15,690 N-m13,075 N-m
Spool-up Time to Rated Speed48 minutes (9,700 RPM)35 minutes (8,100 RPM)
Spool-up Time to Stabilization 24 minutes (8,245 RPM)22 minutes (6,885 RPM)
Spool-up Power
AC Motor
DC Control

2300 Watts Max
125 Watts

2300 Watts Max
125 Watts
Operating Power
AC Motor (Sea state dependent)
DC Control
1050-2300 Watts
125 Watts
1050-2300 Watts
125 Watts
Voltage
AC Input
DC Input
110-120 VAC @ 30 Amps or
208-230 VAC @ 20 Amps Nominal (±10%), 50/60 Hz, Single Phase
12 VDC @ 15 Amps
110-120 VAC @ 30 Amps or
208-230 VAC @ 20 Amps Nominal (±10%), 50/60 Hz, Single Phase
12 VDC @ 15 Amps
Seawater Supply to Heat Exchanger8 GPM (30 LPM) maximum
4 GPM (15 LPM) minimum
8 GPM (30 LPM) maximum
4 GPM (15 LPM) minimum
Ambient Air Temperature32˚ – 140˚F (0 – 60˚C)32˚ – 140˚F (0 – 60˚C)
Weight870 lbs (395 kg) bolt-in870 lbs (395 kg) bolt-in
Envelope Dimensions30.1 L x 29.8 W x 24.7 H (inches)
0.77 L x 0.76 W x 0.63 H (meters)
30.1 L x 29.8 W x 24.7 H (inches)
0.77 L x 0.76 W x 0.63 H (meters)
Noise OutputAt full operating RPM, steady state noise measured in the factory at a 1-meter distance measures 70-75 dBC (sound levels may be higher during spool-up).At full operating RPM, steady state noise measured in the factory at a 1-meter distance measures 70-75 dBC (sound levels may be higher during spool-up).

Arrangement
The Seakeeper 6 consists of the Flywheel, Enclosure, Foundation, Electronics, Brake, Cooling, and Cover Subsystems.

Installation Location
The Seakeeper is a torque device and does not have to be installed in a specific hull location or on the centerline. However, the Seakeeper should not be installed forward of the longitudinal center of gravity to minimize high acceleration loading due to hull/wave impacts during operation at high speed or in large waves.

Mounting Dimensions
See Drawing No. 90398 – Seakeeper 5/6 Bolt-In Installation Details.
See Drawing No. 90399 – Seakeeper 5/6 Bond-In Installation Details.

Loads
The installer is responsible for designing the foundation to which the Seakeeper is attached and for ensuring that this foundation can safely transfer the concentrated Seakeeper loads from the frame to the adjacent hull structure. Loads that the Seakeeper imposes on the hull structure are explained on Drawing No. 90398 – Seakeeper 5/6 Bolt-In Installation Details and Drawing No. 90399 – Seakeeper 5/6 Bond-In Installation Details; these loads do NOT include vessel motion accelerations, such as vertical slam loads which can be high for higher speed vessels.

Cooling
The Seakeeper bearings, Motor Drive Box, and hydraulic manifold are cooled by a closed water / glycol mix cooling loop that incorporates a seawater heat exchanger. The installer is responsible for providing 4 – 8 GPM (15 – 30 LPM) raw water at ambient sea temperature and a maximum pressure of 20 psi (1.4 bar) to the heat exchanger.

Electrical
The installer is responsible for supplying 110 or 230 VAC, 50/60 Hz, single phase power on a 30 A or 20 A, respectively, service to the Motor Drive Box and 12 VDC at 15 A service to the Seakeeper Control System. Separate circuit breakers should be used for each Motor Drive Box in multiple Seakeeper installations. Similarly, separate circuit breakers should be used for each Seakeeper Control System in multiple Seakeeper installations.

Operator Controls
A Display with integrated Keypad is used to start, operate, monitor, and shutdown the Seakeeper.

Performance
Reduction of boat roll is a function of the boat’s displacement, transverse metacentric height (GMT) and hull damping as well as the operating conditions (speed and heading with respect to waves) and sea state. The Seakeeper controller regulates the active hydraulic brake to ensure the Seakeeper’s anti-roll torque is maximized regardless of hull characteristics or operating conditions.

Alarm and Monitoring
Sensors, alarms and shutdowns are provided to allow unattended operation. Sensors measure Seakeeper and drive temperatures, vacuum pressure, gimbal angle, brake pressure, and ship motion. The Seakeeper controller sends sensor values and alarm information to the display and also locks the brake and shuts down the motor drive in the event of an alarm condition. Seakeeper operating history during faults or alarms is recorded in the controller’s memory for subsequent recall if service is needed. Seakeeper may access the Seakeeper’s software to gather run hours, bearing loading, and hull slamming information.

Safety
The brake automatically locks the Seakeeper so it cannot generate excessive anti-rolling torque loads in the event of a system fault or alarm, loss of electrical power or loss of brake pressure. The brake can be locked from the Display or by shutting off power locally at the Motor Drive Box or Seakeeper Control System.