Seakeeper 5 / 6 Operation Manual (90403-5); S/N 6/5-233-5847 to 6/5-243-6941
7.0 Specifications and Summary
Seakeeper 6 | Seakeeper 5 | |
---|---|---|
Rated RPM | 9,700 RPM | 8,100 RPM |
Angular Momentum at Rated RPM | 6,000 N-m-s | 5,000 N-m-s |
Anti-Rolling Torque at Rated RPM | 15,690 N-m | 13,075 N-m |
Spool-up Time to Rated Speed | 42 minutes (9,700 RPM) | 35 minutes (8,100 RPM) |
Spool-up Time to Stabilization | 21 minutes (7,275 RPM) | 22 minutes (6,885 RPM) |
Spool-up Power AC Motor DC Control | 2300 Watts Max 125 Watts | 2300 Watts Max 125 Watts |
Operating Power AC Motor (Sea state dependent) DC Control | 1100-2300 Watts 125 Watts | 1100-2300 Watts 125 Watts |
Voltage AC Input DC Input | 110-120 VAC @ 30 A or 208-230 VAC @ 20 A Nominal (±10%), 50/60 Hz, Single Phase 12 VDC @ 15 A for Control Power 12 VDC @ 15 A / 24 VDC @ 10 A for Seawater Pump | 110-120 VAC @ 30 Amps or 208-230 VAC @ 20 Amps Nominal (±10%), 50/60 Hz, Single Phase 12 VDC @ 15 Amps for Control Power 12 VDC @ 15 A / 24 VDC @ 10 A for Seawater Pump |
Seawater Supply to Heat Exchanger | 2.5 GPM (9.5 LPM) minimum 8 GPM (30.3 LPM) maximum | 2.5 GPM (9.5 LPM) minimum 8 GPM (30.3 LPM) maximum |
Ambient Air Temperature | 32˚ – 140˚F (0 – 60˚C) | 32˚ – 140˚F (0 – 60˚C) |
Weight | 870 lbs (395 kg) bolt-in | 870 lbs (395 kg) bolt-in |
Envelope Dimensions | 30.1 L x 29.7 W x 24.5 H (inches) 0.76 L x 0.76 W x 0.62 H (meters) | 30.1 L x 29.7 W x 24.5 H (inches) 0.76 L x 0.76 W x 0.62 H (meters) |
Noise Output | At full operating RPM, steady state noise measured in the factory at a 1-meter distance measures <72 dBC (sound levels may be higher during spool-up). | At full operating RPM, steady state noise measured in the factory at a 1-meter distance measures <72 dBC (sound levels may be higher during spool-up). |

Arrangement
The Seakeeper 6 consists of the Flywheel, Enclosure, Foundation, Electronics, Brake, Cooling, and Cover Subsystems.
Installation Location
The Seakeeper is a torque device and does not have to be installed in a specific hull location or on the centerline. However, the Seakeeper should not be installed forward of the longitudinal center of gravity to minimize high acceleration loading due to hull/wave impacts during operation at high speed or in large waves.
Mounting Dimensions
See Drawing No. 90398 – Seakeeper 5/6 Bolt-In Installation Details.
See Drawing No. 90399 – Seakeeper 5/6 Bond-In Installation Details.
Loads
The installer is responsible for designing the foundation to which the Seakeeper is attached and for ensuring that this foundation can safely transfer the concentrated Seakeeper loads from the frame to the adjacent hull structure. Loads that the Seakeeper imposes on the hull structure are explained on Drawing No. 90398 – Seakeeper 5/6 Bolt-In Installation Details and Drawing No. 90399 – Seakeeper 5/6 Bond-In Installation Details; these loads do NOT include vessel motion accelerations, such as vertical slam loads which can be high for higher speed vessels.
Cooling
The Seakeeper bearings, Motor Drive Box, and hydraulic manifold are cooled by a closed water / glycol mix cooling loop that incorporates a seawater heat exchanger. The installer is responsible for providing 2.5 – 8 GPM (9.5 – 30.3 LPM) raw water at ambient sea temperature and a maximum pressure of 20 psi (1.4 bar) to the heat exchanger.
Electrical
The installer is responsible for supplying 110 or 230 VAC, 50/60 Hz, single phase power on a 30 A or 20 A, respectively, service to the Motor Drive Box. The installer is also responsible for supplying 12 VDC at 15 A service to the Seakeeper Control System and 12 VDC at 15 A or 24 VDC at 10 A for DC Seawater Pump. Separate circuit breakers should be used for each Motor Drive Box in multiple Seakeeper installations. Similarly, separate circuit breakers should be used for each Seakeeper Control System and Seawater Pump in multiple Seakeeper installations.
Operator Controls
The ConnectBox may be used locally to start, unlock or lock the Seakeeper, or shutdown the Seakeeper. A compatible MFD or Seakeeper 5″ Touch Display is also required for remote operation of the Seakeeper and to change settings and address or review alarms.
Performance
Reduction of boat roll is a function of the boat’s displacement, transverse metacentric height (GMT) and hull damping as well as the operating conditions (speed and heading with respect to waves) and sea state. The Seakeeper controller regulates the active hydraulic brake to ensure the Seakeeper’s anti-roll torque is maximized regardless of hull characteristics or operating conditions.
Alarm and Monitoring
Sensors, alarms and shutdowns are provided to allow unattended operation. Sensors measure Seakeeper and drive temperatures, gimbal angle, brake pressure, and ship motion. The Seakeeper controller sends sensor values and alarm information to the MFD / 5″ touch display and also locks the brake and shuts down the motor drive in the event of an alarm condition. Seakeeper operating history during faults or alarms is recorded in the controller’s memory for subsequent recall if service is needed. Seakeeper may access the Seakeeper’s software to gather run hours, bearing loading, and hull slamming information.
Safety
The brake automatically locks the Seakeeper so it cannot generate excessive anti-rolling torque loads in the event of a system fault or alarm, loss of electrical power or loss of brake pressure. The brake can be locked from the remote display or locally at the ConnectBox by shutting off power to the Motor Drive Box or Seakeeper Control System.