{"id":9783,"date":"2022-02-28T13:57:18","date_gmt":"2022-02-28T13:57:18","guid":{"rendered":"https:\/\/manuals.seakeeper.com\/seakeeper-18-operation-manual-90673-1-draft-copy\/specifications-and-summary\/"},"modified":"2022-03-01T15:00:34","modified_gmt":"2022-03-01T15:00:34","slug":"specifications-and-summary","status":"publish","type":"page","link":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-16-18-operation-manual\/specifications-and-summary\/","title":{"rendered":"Specifications and Summary"},"content":{"rendered":"\n<figure class=\"wp-block-table\"><table><thead><tr><th><\/th><th><span translate=\"no\">Seakeeper<\/span> 16<\/th><th><span translate=\"no\">Seakeeper<\/span> 18<\/th><\/tr><\/thead><tbody><tr><td><strong>Rated RPM<\/strong><\/td><td>6,130 RPM  <\/td><td>7,000 RPM <\/td><\/tr><tr><td><strong>Angular Momentum at Rated RPM<\/strong><\/td><td>16,000 N-m-s  <\/td><td>18,000 N-m-s <\/td><\/tr><tr><td><strong>Anti-Rolling Torque at Rated RPM<\/strong><\/td><td>30,720 N-m  <\/td><td>34,980 N-m <\/td><\/tr><tr><td><strong>Spool-up Time to Rated Speed<\/strong><\/td><td>40 minutes (6,130 RPM)  <\/td><td>50 minutes (7,000 RPM) <\/td><\/tr><tr><td><strong>Spool-up Time to Stabilization <\/strong><\/td><td>30 minutes (5,210 RPM)  <\/td><td>35 minutes (5,950 RPM) <\/td><\/tr><tr><td><strong>Spool-up Power<\/strong><br>AC Motor<br>DC Control<\/td><td>3,700 Watts Max<br>240 Watts <\/td><td>3,700 Watts Max<br>240 Watts<\/td><\/tr><tr><td><strong>Operating Power<\/strong><br>AC Motor (Sea state dependent)<br>DC Control<\/td><td>2,300-3,700 Watts<br>240 Watts <\/td><td>2,300-3,700 Watts<br>240 Watts<\/td><\/tr><tr><td><strong>Voltage<\/strong><br>AC Input<br>DC Input<\/td><td> <br>208-230 VAC (\u00b110%), 50\/60 Hz, Single Phase<br>24 VDC @ 10 Amps  <\/td><td> <br>208-230 VAC (\u00b110%), 50\/60 Hz, Single Phase<br>24 VDC @ 10 Amps <\/td><\/tr><tr><td><strong>Seawater Pump<\/strong><br>DC Voltage<\/td><td>24 VDC<br>Fuse\/Breaker 10 A Max<br>Alternate Seawater Pump: 24 VDC @ 20 A Max <\/td><td>24 VDC<br>Fuse\/Breaker 10 A Max<br>Alternate Seawater Pump: 24 VDC @ 20 A Max<\/td><\/tr><tr><td><strong>Seawater Supply to Heat Exchanger<\/strong><\/td><td>8 GPM (30 LPM) maximum<br>4 GPM (15 LPM) minimum  <\/td><td>8 GPM (30 LPM) maximum<br>4 GPM (15 LPM) minimum <\/td><\/tr><tr><td><strong>Ambient Air Temperature<\/strong><\/td><td>32\u02da &#8211; 140\u02daF (0 &#8211; 60\u02daC)  <\/td><td>32\u02da &#8211; 140\u02daF (0 &#8211; 60\u02daC) <\/td><\/tr><tr><td><strong>Weight<\/strong><\/td><td>2,270 lbs (1,030 kg) bolt-in  <\/td><td>2,270 lbs (1,030 kg) bolt-in <\/td><\/tr><tr><td><strong>Envelope Dimensions<\/strong><\/td><td>42.6 L x 43.2 W x 32.9 H (inches)<br>1.08 L x 1.1 W x 0.84 H (meters)  <\/td><td>42.6 L x 43.2 W x 32.9 H (inches)<br>1.08 L x 1.1 W x 0.84 H (meters) <\/td><\/tr><tr><td><strong>Noise Output<\/strong><\/td><td>At full operating RPM, steady state noise measured in the factory at a 1-meter distance measures 61-64 dBC (sound levels may be higher during spool-up).  <\/td><td>At full operating RPM, steady state noise measured in the factory at a 1-meter distance measures 66-68 dBC (sound levels may be higher during spool-up). <\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"539\" height=\"440\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/SEAKEEPER-18-Front-Isometric-View-e1642694626266.jpg\" alt=\"\" class=\"wp-image-4492\"\/><\/figure><\/div>\n\n\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Arrangement<\/strong><br>The <span translate=\"no\">Seakeeper<\/span> 16\/18 consists of the Flywheel, Enclosure, Foundation, Electronics, Brake, Cooling, and Cover Subsystems.<br><br><strong>Installation Location<br><\/strong>The <span translate=\"no\">Seakeeper<\/span> is a torque device and does not have to be installed in a specific hull location or on the vessel\u2019s centerline. However, the <span translate=\"no\">Seakeeper<\/span> should not be installed forward of amidships to minimize high acceleration loading due to hull-to-wave impacts during operation at high speed or in large waves. Contact <span translate=\"no\">Seakeeper<\/span> if a forward installation location is being considered.<br><br><strong>Mounting Dimensions<br><\/strong>See Drawing No. 90544 \u2013 <span translate=\"no\">Seakeeper<\/span> 18 Bolt-In Installation Details.<br>See Drawing No. 90545 \u2013 <span translate=\"no\">Seakeeper<\/span> 18 Bond-In Installation Details.<br><br><strong>Loads<\/strong><br>The installer is responsible for designing the foundation to which the <span translate=\"no\">Seakeeper<\/span> is attached and for ensuring that this foundation can safely transfer the concentrated <span translate=\"no\">Seakeeper<\/span> loads from the frame to the adjacent hull structure.\u00a0 Loads that the <span translate=\"no\">Seakeeper<\/span> imposes on the hull structure are explained on Drawing No.  90544 \u2013 <span translate=\"no\">Seakeeper<\/span> 18 Bolt-In Installation Details and Drawing No. 90545 \u2013 <span translate=\"no\">Seakeeper<\/span> 18 Bond-In Installation Details; these loads do NOT include vessel motion accelerations, such as vertical slam loads which can be significant for higher speed vessels.<br><br><strong>Cooling<\/strong><br>The <span translate=\"no\">Seakeeper<\/span> bearings, Motor Drive Box, and hydraulic manifold are cooled by a closed water \/ glycol mix cooling loop that incorporates a sea water heat exchanger.\u00a0 The installer is responsible for providing 4 &#8211; 8 GPM (15 \u2013 30 LPM) raw water at ambient sea temperature and 30 psi (2.1 bar) maximum pressure to the heat exchanger. <span translate=\"no\">Seakeeper<\/span> offers a 24 VDC seawater cooling pump (P\/N 30322).<br><br><strong>Electrical<\/strong><br>The installer is responsible for supplying 208-230 VAC, 50\/60 Hz, single phase power on a 25 A service to the Motor Drive Box and 24 VDC @ 10 A service to the <span translate=\"no\">Seakeeper<\/span> Control System. A separate 24 VDC breaker is required for the seawater cooling pump power supply. Separate circuit breakers should be used for each Motor Drive Box in multiple <span translate=\"no\">Seakeeper<\/span> installations.\u00a0 Similarly, separate circuit breakers should be used for each <span translate=\"no\">Seakeeper<\/span> Control System DC Seawater pump in multiple <span translate=\"no\">Seakeeper<\/span> installations.<br><br><strong>Operator Controls<br><\/strong>A Display with integrated Keypad is used to start, operate, monitor, and shutdown the <span translate=\"no\">Seakeeper<\/span>. <br><br><strong>Performance<\/strong><br>Reduction of boat roll is a function of the boat\u2019s displacement, transverse metacentric height (GM<sub>T<\/sub>) and hull damping as well as the operating conditions (speed and heading with respect to waves) and sea state.\u00a0 The <span translate=\"no\">Seakeeper<\/span> controller regulates the active hydraulic brake to ensure the <span translate=\"no\">Seakeeper<\/span>\u2019s anti-roll torque is maximized irrespective of hull characteristics or operating conditions.<br><br><strong>Alarm and Monitoring<\/strong><br>Sensors, alarms and shutdowns are provided to allow unattended operation.\u00a0 Sensors measure <span translate=\"no\">Seakeeper<\/span> and drive temperatures, vacuum pressure, gimbal angle, brake pressure, and ship motion.\u00a0 The <span translate=\"no\">Seakeeper<\/span> controller sends sensor values and alarm information to the display and also locks the brake and shuts down the motor drive in the event of an alarm condition.\u00a0 <span translate=\"no\">Seakeeper<\/span> operating history during faults or alarms is recorded in the controller\u2019s memory for subsequent recall if service is needed.\u00a0 <span translate=\"no\">Seakeeper<\/span> may access the <span translate=\"no\">Seakeeper<\/span>\u2019s software to gather run hours, bearing loading, and hull slamming information.<br><br><strong>Safety<\/strong><br>The brake automatically locks the <span translate=\"no\">Seakeeper<\/span> so it cannot generate excessive anti-rolling torque loads in the event of a system fault or alarm, loss of electrical power or loss of brake pressure.\u00a0 The brake can be locked from the Display or by shutting off AC and DC power at the supply breakers.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Seakeeper 16 Seakeeper 18 Rated RPM 6,130 RPM 7,000 RPM Angular Momentum at Rated RPM 16,000 N-m-s 18,000 N-m-s Anti-Rolling Torque at Rated RPM 30,720 N-m 34,980 N-m Spool-up Time to Rated Speed 40 minutes (6,130 RPM) 50 minutes (7,000 RPM) Spool-up Time to Stabilization 30 minutes (5,210 RPM) 35 minutes (5,950 RPM) Spool-up PowerAC [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"parent":9718,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"manual":[256],"model":[],"document_type":[],"hidden":[],"class_list":["post-9783","page","type-page","status-publish","hentry","manual-seakeeper-16-18-operation-manual"],"acf":[],"_links":{"self":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/9783","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/comments?post=9783"}],"version-history":[{"count":4,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/9783\/revisions"}],"predecessor-version":[{"id":9984,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/9783\/revisions\/9984"}],"up":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/9718"}],"wp:attachment":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/media?parent=9783"}],"wp:term":[{"taxonomy":"manual","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/manual?post=9783"},{"taxonomy":"model","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/model?post=9783"},{"taxonomy":"document_type","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/document_type?post=9783"},{"taxonomy":"hidden","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/hidden?post=9783"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}