{"id":9704,"date":"2022-02-28T13:46:22","date_gmt":"2022-02-28T13:46:22","guid":{"rendered":"https:\/\/manuals.seakeeper.com\/seakeeper-18-installation-manual-90672-1-draft-copy\/4-0-startup\/4-1-startup-instructions\/"},"modified":"2022-03-01T19:47:29","modified_gmt":"2022-03-01T19:47:29","slug":"4-1-startup-instructions","status":"publish","type":"page","link":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-16-18-installation-manual\/4-0-startup\/4-1-startup-instructions\/","title":{"rendered":"Start Up Instructions"},"content":{"rendered":"\n<ol class=\"wp-block-list\"><li>Energize <span translate=\"no\">Seakeeper<\/span> 24 VDC supply at the customer-supplied electrical disconnect.<\/li><li>Supply 208-230 VAC to Motor Drive Box at customer-supplied electrical disconnect.<\/li><li>Turn on the boat\u2019s DC dedicated circuit breaker that supplies power to the DC seawater pump.<\/li><li>With system powered up check the display for any ALARMS. If there are any ALARMS present, they must be corrected first.<\/li><li>Press the <span translate=\"no\">Seakeeper<\/span> ON\/OFF Button on Display. <img loading=\"lazy\" decoding=\"async\" width=\"45\" height=\"30\" class=\"wp-image-9970\" style=\"width: 45px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/power-button.png\" alt=\"\"> The progress bar will appear and indicate how soon the <span translate=\"no\">Seakeeper<\/span> will be available for stabilization. When the <span translate=\"no\">Seakeeper<\/span> is initialized and up to minimum operating speed the stabilize button, <img loading=\"lazy\" decoding=\"async\" width=\"50\" height=\"33\" class=\"wp-image-2198\" style=\"width: 50px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/SEAKEEPER-2-Stabilize-Button.jpg\" alt=\"\"> will appear. At this point, the <span translate=\"no\">Seakeeper<\/span> is available for stabilization.<\/li><\/ol>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"962\" height=\"538\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/Home-Screen-during-spool-up-sequence.jpg\" alt=\"\" class=\"wp-image-1627\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Home-Screen-during-spool-up-sequence.jpg 962w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Home-Screen-during-spool-up-sequence-768x430.jpg 768w\" sizes=\"auto, (max-width: 962px) 100vw, 962px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"961\" height=\"537\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/Home-Screen-with-available-stabilization.jpg\" alt=\"\" class=\"wp-image-1628\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Home-Screen-with-available-stabilization.jpg 961w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Home-Screen-with-available-stabilization-768x429.jpg 768w\" sizes=\"auto, (max-width: 961px) 100vw, 961px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<ol class=\"wp-block-list\" start=\"6\"><li>The seawater pump should have started when the ON\/OFF button on the display was depressed. Confirm pump operation and flow rate, if practical.&nbsp; Required flow is 4 GPM (15 LPM) minimum and 8 GPM (30 LPM) maximum. The Seawater Pump will run for approximately 60 seconds and re-run at any given time when the <span translate=\"no\">Seakeeper<\/span> reaches its temperature threshold (Approximately 131\u00b0F (55\u00b0C))<\/li><li>Verify that there are no ALARMS present. If an ALARM is present it will be displayed.<\/li><li>When the <span translate=\"no\">Seakeeper<\/span> reaches its maximum operating speed where maximum stabilization is available, the progress bar will disappear and the <span translate=\"no\">Seakeeper<\/span> is available for maximum stabilization. Press the stabilize button. <img loading=\"lazy\" decoding=\"async\" width=\"50\" height=\"33\" class=\"wp-image-2198\" style=\"width: 50px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/SEAKEEPER-2-Stabilize-Button.jpg\" alt=\"\"> The button will turn blue indicating that the <span translate=\"no\">Seakeeper<\/span> is stabilizing the roll motion.<\/li><\/ol>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"438\" height=\"239\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/SEAKEEPER-2-Ready-to-Stabilize-Screen.jpg\" alt=\"\" class=\"wp-image-2200\"\/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"386\" height=\"214\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/SEAKEEPER-2-Stabilizing-Screen.jpg\" alt=\"\" class=\"wp-image-2201\"\/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<ol class=\"wp-block-list\" start=\"9\"><li>Verify that there are no ALARMS. If an ALARM is present it will be displayed.<\/li><li>Press the STABILIZE Button <img loading=\"lazy\" decoding=\"async\" width=\"50\" height=\"34\" class=\"wp-image-2202\" style=\"width: 50px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/SEAKEEPER-2-Stabilizing-Button.jpg\" alt=\"\"> to turn stabilization off. Then press the <span translate=\"no\">Seakeeper<\/span> ON\/OFF Button <img loading=\"lazy\" decoding=\"async\" width=\"50\" height=\"34\" class=\"wp-image-1897\" style=\"width: 50px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/Seakeeper_Power_Off_Button.jpg\" alt=\"\">  to power the <span translate=\"no\">Seakeeper<\/span> down.<\/li><li>During normal operation, the <span translate=\"no\">Seakeeper<\/span> should be stopped when stabilization is no longer required.\u00a0 This maximizes long term life as it allows the <span translate=\"no\">Seakeeper<\/span> to start the coast down cycle before cooling is shutoff.\u00a0 Once the vessel is secured in the slip and the crew has shut down the generator and engines, the AC and DC breakers that control the <span translate=\"no\">Seakeeper<\/span> should be switched to the OFF position.\u00a0 The <span translate=\"no\">Seakeeper<\/span> will continue to spool down to 0 RPM.\u00a0 No cooling is required during this time.\u00a0 Note the <span translate=\"no\">Seakeeper<\/span> 16 will take 4.5+ hours to coast down to 0 RPM from full speed. When the flywheel has stopped the display will indicate 0 RPM.<\/li><\/ol>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/Display-Screen-opertion.png\" alt=\"\" class=\"wp-image-9542\" width=\"510\"\/><\/figure><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Energize Seakeeper 24 VDC supply at the customer-supplied electrical disconnect. Supply 208-230 VAC to Motor Drive Box at customer-supplied electrical disconnect. Turn on the boat\u2019s DC dedicated circuit breaker that supplies power to the DC seawater pump. With system powered up check the display for any ALARMS. If there are any ALARMS present, they must [&hellip;]<\/p>\n","protected":false},"author":9,"featured_media":0,"parent":9700,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"manual":[254],"model":[],"document_type":[],"hidden":[],"class_list":["post-9704","page","type-page","status-publish","hentry","manual-seakeeper-16-18-installation-manual-90549-2"],"acf":[],"_links":{"self":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/9704","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/comments?post=9704"}],"version-history":[{"count":3,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/9704\/revisions"}],"predecessor-version":[{"id":10120,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/9704\/revisions\/10120"}],"up":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/9700"}],"wp:attachment":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/media?parent=9704"}],"wp:term":[{"taxonomy":"manual","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/manual?post=9704"},{"taxonomy":"model","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/model?post=9704"},{"taxonomy":"document_type","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/document_type?post=9704"},{"taxonomy":"hidden","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/hidden?post=9704"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}