{"id":9682,"date":"2022-02-28T13:46:22","date_gmt":"2022-02-28T13:46:22","guid":{"rendered":"https:\/\/manuals.seakeeper.com\/seakeeper-18-installation-manual-90672-1-draft-copy\/2-0-electrical-installation\/2-1-electrical-equipment-power-connections\/"},"modified":"2023-02-17T14:32:05","modified_gmt":"2023-02-17T14:32:05","slug":"2-1-electrical-equipment-power-connections","status":"publish","type":"page","link":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-16-18-installation-manual\/2-0-electrical-installation\/2-1-electrical-equipment-power-connections\/","title":{"rendered":"Electrical Equipment Power Connections"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" style=\"font-size:25px\">230 VAC Power Source Requirements<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>230 VAC (nominal), 1 Phase, 50\/60 Hz, 30 A<\/li>\n\n\n\n<li>With installations of more than one <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span>, a separate circuit breaker should be used for each <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> Motor Drive Box.<\/li>\n<\/ol>\n\n\n\n\n\n<h2 class=\"wp-block-heading\" style=\"font-size:25px\">Drive Box AC Power Input Connection Instructions<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Cable: 3 x 10 AWG (3 x 6 mm<sup>2<\/sup> CSA), 10 ft (3 m) length, <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> supplied pre-installed.\n<ol class=\"wp-block-list\">\n<li>Locate Cable 2 for AC power input to the Motor Drive Box at the outward of two cable glands.<br><br><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"389\" class=\"wp-image-4504\" style=\"width: 600px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/SEAKEEPER-18-Drive-Box-AC-Power-Input-and-Output-Cable-Glands.jpg\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SEAKEEPER-18-Drive-Box-AC-Power-Input-and-Output-Cable-Glands.jpg 1098w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SEAKEEPER-18-Drive-Box-AC-Power-Input-and-Output-Cable-Glands-768x497.jpg 768w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><br><em><sub><strong>Figure 2 \u2013<\/strong> Motor Drive Box AC Power Input &amp; Output Cable Glands<\/sub><\/em><br><br><br><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"164\" class=\"wp-image-4239\" style=\"width: 500px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/Cable-2-Wire-Connections-at-AC-Power-Distribution-Panel.jpg\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Cable-2-Wire-Connections-at-AC-Power-Distribution-Panel.jpg 868w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Cable-2-Wire-Connections-at-AC-Power-Distribution-Panel-768x252.jpg 768w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><br><em><sub><strong>Figure 3 \u2013 <\/strong>Cable 2 Wire Connections at AC Power Distribution Panel<\/sub><\/em><\/li>\n\n\n\n<li>Connect 230 VAC wires in Cable 2 to a 30 A, double-pole Circuit Breaker at an AC power distribution panel according to Figure 3 above.<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n\n\n\n\n\n<h2 class=\"wp-block-heading\" style=\"font-size:25px\">DC Power Output to Seawater Pump Connection Instructions<\/h2>\n\n\n\n<ol class=\"wp-block-list\" start=\"2\">\n<li>Cable 5: P\/N 20455, DC Output Power, 14 AWG, DTP Male-Female, Cable Assembly, <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> supplied (5 m length)<\/li>\n\n\n\n<li>Cable 8: P\/N 20454, DC Input Power, 14 AWG, DTP Female Only, Cable Assembly, <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> supplied (5 m length)<\/li>\n\n\n\n<li><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> P\/N 30322, Seawater Pump rated at 24 VDC, Fuse or Circuit Breaker 10 A Required\n<ol class=\"wp-block-list\">\n<li>Alternative: Seawater Pump rated at 24 VDC, Max Fuse Rating Labeled by MFR (LESS THAN 20 A)<br><br><img loading=\"lazy\" decoding=\"async\" width=\"150\" height=\"95\" class=\"wp-image-1505\" style=\"width: 150px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/warning-icon.jpg\" alt=\"\"><strong>Verify that DC power is OFF to the Drive Box before connecting both cables to a Seawater Pump.<\/strong><\/li>\n\n\n\n<li>Locate Cable 5: P\/N 20455, DC Seawater Pump Output Power Cable Male-Female connection to the DC &#8220;Seawater Pump-Out&#8221; from the Wire Harness.<br><br><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"419\" class=\"wp-image-4509\" style=\"width: 600px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/SEAKEEPER-18-Cable-5-DC-Seawater-Pump-Output-Power-Cable-Male-Female.jpg\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SEAKEEPER-18-Cable-5-DC-Seawater-Pump-Output-Power-Cable-Male-Female.jpg 802w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SEAKEEPER-18-Cable-5-DC-Seawater-Pump-Output-Power-Cable-Male-Female-768x536.jpg 768w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><br><em><sub><strong>Figure 4a \u2013 <\/strong>Cable 5, P\/N 20455, DC Seawater Pump Output Power Cable, Male-Female<\/sub><\/em><\/li>\n\n\n\n<li>Locate Cable 8: P\/N 20454, DC Seawater Pump Input Power Cable, Female Only connection to the DC &#8220;Seawater Pump-In&#8221; from the Wire Harness. Stripped end to be connected to a 24 VDC power source.<br><br><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"501\" class=\"wp-image-4510\" style=\"width: 600px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/SEAKEEPER-18-Cable-8-DC-Seawater-Pump-Input-Power-Cable-Female-Only.jpg\" alt=\"\"><br><em><sub><strong>Figure 4b <\/strong>\u2013 Cable 8, P\/N 20454, DC Seawater Pump Input Power Cable, Female Only<\/sub><\/em> <\/li>\n\n\n\n<li>Connect Cable 8, P\/N 20454, DC Seawater Pump, Input Power Cable, Female Only wires to a 24 VDC power source according to Figure 5.<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/SEAKEEPER-26-Recommended-Wiring-for-Seawater-Pumps-Not-230-VAC.jpg\" alt=\"\" class=\"wp-image-4759\" width=\"737\" height=\"433\"\/><figcaption class=\"wp-element-caption\"><em><strong>Figure 5 \u2013<\/strong> Cable 5 &amp; 8, Wire Connections to DC Seawater Pump and 24 VDC Power Source<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n\n\n<h2 class=\"wp-block-heading\" style=\"font-size:25px\">24 VDC Power Source Requirements<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>24 VDC, 10 A<\/li>\n\n\n\n<li>A separate breaker should be used for each <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span>.<\/li>\n\n\n\n<li>Wire Harness, 24 VDC, 10 A<\/li>\n<\/ol>\n\n\n\n\n\n<h2 class=\"wp-block-heading\" style=\"font-size:25px\">DC Power Connection Instructions<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\"><div class=\"wp-block-image\">\n<figure class=\"alignright size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/warning-icon.jpg\" alt=\"\" class=\"wp-image-1505\" width=\"159\" height=\"100\"\/><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p><strong>Reversing polarity on the DC power input to the <span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span> can result in damaging the electronics in the control system.<\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<ol class=\"wp-block-list\">\n<li>24 VDC, 10 A, 2 x 12 AWG (3 x 4 mm<sup>2<\/sup> CSA) customer supplied.\n<ol class=\"wp-block-list\">\n<li>Install <span translate=\"no\"><span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span><\/span> provided DC Power Input Cable, P\/N 20248, as Cable 1.\n<ol class=\"wp-block-list\">\n<li>Route Cable 1 to DC Power Distribution Panel.<\/li>\n\n\n\n<li>Terminate red conductor to +24 VDC. Terminate black conductor to 24 V Rtn or 0 VDC.<\/li>\n<\/ol>\n<\/li>\n\n\n\n<li>Before connecting Cable 1 to <span translate=\"no\"><span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span><\/span>, check for proper voltage and polarity with a DC multimeter using Figure 6 below.<\/li>\n\n\n\n<li>Connect Cable 1 to 24 VDC input receptacle on <span translate=\"no\"><span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span><\/span>.<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/DC-Power-Input-Connector-Contact-Assignments-Front.jpg\" alt=\"\" class=\"wp-image-4255\" width=\"290\" height=\"206\"\/><figcaption class=\"wp-element-caption\"><em><strong>Figure 6 \u2013 <\/strong>DC Power Input Connector Contact Assignments (front)<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\"><div class=\"wp-block-image\">\n<figure class=\"alignright size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/warning-icon.jpg\" alt=\"\" class=\"wp-image-1505\" width=\"158\" height=\"100\"\/><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p><strong>When energizing DC power for the first time, if Display does not power up immediately then disconnect and inspect connector polarity.<\/strong><\/p>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>230 VAC Power Source Requirements Drive Box AC Power Input Connection Instructions DC Power Output to Seawater Pump Connection Instructions 24 VDC Power Source Requirements DC Power Connection Instructions Reversing polarity on the DC power input to the Seakeeper can result in damaging the electronics in the control system. When energizing DC power for the [&hellip;]<\/p>\n","protected":false},"author":9,"featured_media":0,"parent":9678,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"manual":[254],"model":[],"document_type":[],"hidden":[],"class_list":["post-9682","page","type-page","status-publish","hentry","manual-seakeeper-16-18-installation-manual-90549-2"],"acf":[],"_links":{"self":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/9682","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/comments?post=9682"}],"version-history":[{"count":3,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/9682\/revisions"}],"predecessor-version":[{"id":12226,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/9682\/revisions\/12226"}],"up":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/9678"}],"wp:attachment":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/media?parent=9682"}],"wp:term":[{"taxonomy":"manual","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/manual?post=9682"},{"taxonomy":"model","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/model?post=9682"},{"taxonomy":"document_type","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/document_type?post=9682"},{"taxonomy":"hidden","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/hidden?post=9682"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}