{"id":8473,"date":"2022-01-12T17:09:50","date_gmt":"2022-01-12T17:09:50","guid":{"rendered":"https:\/\/manuals.seakeeper.com\/seakeeper-1-installation-manual-90519-1-copy\/electrical-installation\/electrical-equipment-connections\/"},"modified":"2025-04-16T13:37:09","modified_gmt":"2025-04-16T13:37:09","slug":"electrical-equipment-connections","status":"publish","type":"page","link":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-1-installation-manual-90519-2\/electrical-installation\/electrical-equipment-connections\/","title":{"rendered":"3.2  Electrical Equipment Connections"},"content":{"rendered":"\n<h3 class=\"wp-block-heading\">3.2.1 High Current 12 VDC Power<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Source<\/strong><\/td><td>Battery Bank, 12 VDC, Marine, Deep Cycle<\/td><\/tr><tr><td><strong>Voltage Range<\/strong><\/td><td>11.2 \u2013 14.7 VDC<\/td><\/tr><tr><td><strong>Continuous Current<\/strong><\/td><td>55 A<\/td><\/tr><tr><td><strong>Overcurrent Protection<\/strong><\/td><td>80 A (Customer Supplied)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">High Current 12 VDC Power Connection Instructions<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Connect positive and negative High-Current 12 VDC cables, 2 AWG (33.6 mm<sup>2<\/sup>) conductors, to the 12 VDC power source.<br>\n<ol class=\"wp-block-list\">\n<li>The positive and negative cables are supplied with a length of 1.8 m, and approximately 0.5 m is routed within the gyro frame (1.3 m outside frame).<\/li>\n<\/ol>\n<\/li>\n\n\n\n<li>Splice customer-supplied 2 AWG conductors to the positive and negative 2 AWG cables per the Crimping Instructions of Figure 4, using <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span>-supplied butt connectors, to increase conductors to the desired length. <strong>The maximum cable length is 29.53 ft (9.0 m) each<\/strong>. See also Figure 4 below for splicing.<\/li>\n\n\n\n<li>Crimp the positive High-Current Cable to B+ Conductor (red). Conductor should be continuous throughout entire length; do not coil. The most direct route to the 12 VDC power source should be used.<br>\n<ol class=\"wp-block-list\">\n<li>Repeat Step 3 for the negative High-Current Cable to B- Conductor (black).<\/li>\n\n\n\n<li>Install approximately 2 in. (51 mm) of double wall (adhesive lined) heat shrink tubing over entire butt connector and onto both sides of conductor insulation.<\/li>\n<\/ol>\n<\/li>\n\n\n\n<li>Connect positive conductor (B+, red) through dedicated 80 A overcurrent protection device (customer-supplied) and a dedicated isolation switch (customer-supplied), then directly to battery plus terminal or bus bar.<\/li>\n\n\n\n<li>Connect negative conductor (B-, black) directly to battery minus terminal or DC negative bus.<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1634\" height=\"710\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SK1-CBD.png\" alt=\"\" class=\"wp-image-19898\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SK1-CBD.png 1634w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SK1-CBD-768x334.png 768w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SK1-CBD-1536x667.png 1536w\" sizes=\"auto, (max-width: 1634px) 100vw, 1634px\" \/><figcaption class=\"wp-element-caption\"><br><em><strong>Figure 3 \u2013 <\/strong><span translate=\"no\">Seakeeper<\/span> 1 Cable Block Diagram (Drawing No. 90511) \u2013 <\/em><br><em>High Current Connection Highlighted<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\"><div class=\"wp-block-image\">\n<figure class=\"alignright size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"253\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/warning-icon.jpg\" alt=\"\" class=\"wp-image-1505\" style=\"width:158px;height:100px\"\/><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p class=\"has-text-align-left\"><strong><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-red-color\">Reversing polarity on the DC power input to the <span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span> can result in damaging the electronics in the control system.<\/mark> <\/strong><\/p>\n<\/div>\n<\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1403\" height=\"540\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/High-Current-DC-Input-Crimping-Instructions.jpg\" alt=\"\" class=\"wp-image-1479\" style=\"width:825px;height:317px\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/High-Current-DC-Input-Crimping-Instructions.jpg 1403w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/High-Current-DC-Input-Crimping-Instructions-768x296.jpg 768w\" sizes=\"auto, (max-width: 1403px) 100vw, 1403px\" \/><figcaption class=\"wp-element-caption\"><br><em><strong>Figure 4 \u2013 <\/strong>High Current DC Input Crimping Instructions<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<hr class=\"wp-block-separator is-style-wide\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">3.2.2  Seawater Pump 12 VDC Power<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Power Source<\/strong><\/td><td>Battery Bank, 12 VDC, Marine, Deep Cycle<\/td><\/tr><tr><td><strong>Voltage Range<\/strong><\/td><td>11.2 \u2013 14.7 VDC<\/td><\/tr><tr><td><strong>Current Rating<\/strong><\/td><td>Max 15 A rating<\/td><\/tr><tr><td><strong>Overcurrent Protection<\/strong><\/td><td>Per pump specification, max 15 A<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Seawater Pump 12 VDC Power Input Connection Instructions<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Connect Seawater Pump Input Cable (P\/N: 30327) to <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> 1 \u201cSW Pump DC In\u201d as shown in <em>Drawing No. 90511 \u2013 <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> 1 Cable Block Diagram<\/em>, with overcurrent protection corresponding to seawater pump selected.<\/li>\n\n\n\n<li>Connect the 16 AWG (1.5 mm<sup>2<\/sup>) plus conductor (red) through dedicated overcurrent protection device (customer-supplied), maximum of 15 A, to dedicated battery isolation switch.<br>\n<ol class=\"wp-block-list\">\n<li>The positive High-Current 12 VDC cable, 2 AWG B+ conductor (red), is capable of carrying the current for both the High Current and Seawater Pump from the 12 VDC power supply to the battery isolation switch. <\/li>\n<\/ol>\n<\/li>\n\n\n\n<li>Connect the 16 AWG (1.5 mm<sup>2<\/sup>) minus conductor (black) directly to battery minus terminal or DC main negative bus.<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1114\" height=\"533\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Cable-Block-Diagram-4.png\" alt=\"\" class=\"wp-image-11091\" style=\"width:606px;height:291px\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Cable-Block-Diagram-4.png 1114w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Cable-Block-Diagram-4-768x367.png 768w\" sizes=\"auto, (max-width: 1114px) 100vw, 1114px\" \/><figcaption class=\"wp-element-caption\"><em><strong>Figure 5 \u2013<\/strong> <span translate=\"no\">Seakeeper<\/span> 1 Cable Block Diagram (Dwg No. 90511) \u2013 Seawater Input<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<h3 class=\"wp-block-heading\">Seawater Pump 12 VDC Power Output Connection Instructions<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Connect Seawater Pump Output Cable to the <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> 1 \u201cSW Pump 12 VDC Out\u201d for DC power output to the seawater pump. The cable is a 2 x 16 AWG cable (1.5 mm<sup>2<\/sup>), 16 ft (5 m) length, with a size 16 female Deutsch plug.<\/li>\n\n\n\n<li>Pumps rated at 12 VDC, 15 A maximum, customer-supplied, must be configured with a Deutsch DT series, 2-pin receptacle to mate with the connector shown in figure 6.<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"499\" height=\"302\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/ABLE-5-Seawater-Pump-Deutsch-Connector.jpg\" alt=\"\" class=\"wp-image-1486\" style=\"width:340px;height:206px\"\/><figcaption class=\"wp-element-caption\"><em><strong>Figure 6 \u2013 <\/strong>Seawater Pump Deutsch Connector<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<ol start=\"3\" class=\"wp-block-list\">\n<li>The Seawater Pump Output Cable must be routed and installed in the vessel from the <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> 1 \u201cSW Pump 12 VDC Out\u201d Deutsch connector (pins end) to the DC seawater pump cable Deutsch connector (socket end).<br>\n<ol class=\"wp-block-list\">\n<li>Connect Seawater Pump Output Cable plug end (female end) to the customer-supplied receptacle end (male end). The recommended wiring is shown in the following figure.<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"934\" height=\"246\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/CABLE-5-Seawater-Pump.jpg\" alt=\"\" class=\"wp-image-1488\" style=\"width:565px;height:148px\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/CABLE-5-Seawater-Pump.jpg 934w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/CABLE-5-Seawater-Pump-768x202.jpg 768w\" sizes=\"auto, (max-width: 934px) 100vw, 934px\" \/><figcaption class=\"wp-element-caption\"><br><em><strong>Figure 7 \u2013 <\/strong>Seawater Pump<\/em> <em>Power Output Cable<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<ol start=\"4\" class=\"wp-block-list\">\n<li><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> DC Seawater Pump Assembly (P\/N 30331), which is prewired for DC Seawater Output Cable, is available as an option with the <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> 1.<\/li>\n<\/ol>\n","protected":false},"excerpt":{"rendered":"<p>3.2.1 High Current 12 VDC Power Source Battery Bank, 12 VDC, Marine, Deep Cycle Voltage Range 11.2 \u2013 14.7 VDC Continuous Current 55 A Overcurrent Protection 80 A (Customer Supplied) High Current 12 VDC Power Connection Instructions Reversing polarity on the DC power input to the Seakeeper can result in damaging the electronics in the [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"parent":8469,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"manual":[239],"model":[],"document_type":[],"hidden":[],"class_list":["post-8473","page","type-page","status-publish","hentry","manual-seakeeper-1-installation-manual-90519-2"],"acf":[],"_links":{"self":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/8473","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/comments?post=8473"}],"version-history":[{"count":13,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/8473\/revisions"}],"predecessor-version":[{"id":20105,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/8473\/revisions\/20105"}],"up":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/8469"}],"wp:attachment":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/media?parent=8473"}],"wp:term":[{"taxonomy":"manual","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/manual?post=8473"},{"taxonomy":"model","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/model?post=8473"},{"taxonomy":"document_type","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/document_type?post=8473"},{"taxonomy":"hidden","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/hidden?post=8473"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}