{"id":8471,"date":"2022-01-12T17:09:50","date_gmt":"2022-01-12T17:09:50","guid":{"rendered":"https:\/\/manuals.seakeeper.com\/seakeeper-1-installation-manual-90519-1-copy\/electrical-installation\/introduction\/"},"modified":"2025-04-11T14:58:59","modified_gmt":"2025-04-11T14:58:59","slug":"introduction","status":"publish","type":"page","link":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-1-installation-manual-90519-2\/electrical-installation\/introduction\/","title":{"rendered":"3.1 Electrical Installation Introduction"},"content":{"rendered":"\n<p>This section for electrical installation explains how to mount the electrical equipment and how to connect the electrical cables.<\/p>\n\n\n\n<p><strong>Reference Documents &amp; Drawings:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.seakeeper.com\/technical-library\/?type=&amp;product=&amp;search=90510\" target=\"_blank\" rel=\"noreferrer noopener\">90510 \u2013 <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> 1 Hardware Scope of Supply<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.seakeeper.com\/technical-library\/?type=&amp;product=&amp;search=90511\" target=\"_blank\" rel=\"noreferrer noopener\">90511 \u2013 <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> 1 Cable Block Diagram<\/a><\/li>\n\n\n\n<li><a rel=\"noreferrer noopener\" href=\"https:\/\/www.seakeeper.com\/technical-library\/?type=&amp;product=&amp;search=90512\" target=\"_blank\">90512 \u2013 <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> 1 Cooling Water Schematic<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.seakeeper.com\/technical-library\/?type=&amp;product=&amp;search=90558\" target=\"_blank\" rel=\"noreferrer noopener\">90558 &#8211; ConnectBox Helm Mounting Kit<\/a><\/li>\n\n\n\n<li><a rel=\"noreferrer noopener\" href=\"https:\/\/www.seakeeper.com\/technical-library\/?type=technical-bulletins&amp;product=&amp;search=90191\" target=\"_blank\">TB-90191 \u2013 Seawater Cooling Pump Recommendations<\/a><\/li>\n\n\n\n<li><a rel=\"noreferrer noopener\" href=\"https:\/\/www.seakeeper.com\/technical-library\/?type=&amp;product=&amp;search=90575\" target=\"_blank\">TB-90575 &#8211; DC Installation Kits<\/a><\/li>\n\n\n\n<li><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> Compatibility Technical Bulletins<br>\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.seakeeper.com\/dealer-access\/?type=&amp;product=&amp;search=90478\" target=\"_blank\" rel=\"noreferrer noopener\">TB 90478 \u2013 Garmin and <span translate=\"no\"><span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span><\/span> Compatibility<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.seakeeper.com\/dealer-access\/?type=&amp;product=&amp;search=90479\" target=\"_blank\" rel=\"noreferrer noopener\">TB 90479 \u2013 Raymarine and <span translate=\"no\"><span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span><\/span> Compatibility<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.seakeeper.com\/dealer-access\/?type=&amp;product=&amp;search=90480\" target=\"_blank\" rel=\"noreferrer noopener\">TB 90480 \u2013 Simrad and <span translate=\"no\"><span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span><\/span> Compatibility<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.seakeeper.com\/dealer-access\/?type=&amp;product=&amp;search=90598\" target=\"_blank\" rel=\"noreferrer noopener\">TB 90598 &#8211; Furuno and <span translate=\"no\"><span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span><\/span> Compatibility<\/a><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1190\" height=\"692\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/eakeeper-1-Electrical-Connections.jpg\" alt=\"\" class=\"wp-image-1461\" style=\"width:547px;height:317px\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/eakeeper-1-Electrical-Connections.jpg 1190w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/eakeeper-1-Electrical-Connections-768x447.jpg 768w\" sizes=\"auto, (max-width: 1190px) 100vw, 1190px\" \/><figcaption class=\"wp-element-caption\"><br><em><strong>Figure 1 \u2013<\/strong> <span translate=\"no\">Seakeeper<\/span> 1 Isometric View with Electrical Connections<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<p>The following images show the electrical equipment included with the <span translate=\"no\">Seakeeper<\/span> 1 Hardware Scope of Supply (<em>Drawing No. 90510<\/em>):<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"363\" height=\"293\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Updated-photo-1.jpg\" alt=\"\" class=\"wp-image-11018\" style=\"width:272px;height:220px\"\/><figcaption class=\"wp-element-caption\"> ConnectBox <br>(20415)<\/figcaption><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"586\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/Cable-1-and-2-2AWG-12VDC-Input-Cable-6-4AWG-Ground.jpg\" alt=\"\" class=\"wp-image-1464\" style=\"width:215px;height:210px\"\/><figcaption class=\"wp-element-caption\"> 12 VDC, 2 AWG Input Cables and 4 AWG Ground Cable<br>(20436, 20435, 20437)<\/figcaption><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"451\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/Cable-7-2x16AWG-Pump-Pwr-Input.jpg\" alt=\"\" class=\"wp-image-1465\" style=\"width:240px;height:181px\"\/><figcaption class=\"wp-element-caption\"> DC Seawater Pump Input Power Cable, 2&#215;16 AWG,<br>5 m. Length (30327) <\/figcaption><\/figure>\n<\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"436\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/Cable-5-2x16AWG-Pump-Pwr-Output.jpg\" alt=\"\" class=\"wp-image-1466\" style=\"object-fit:cover;width:240px;height:175px\"\/><figcaption class=\"wp-element-caption\">DC Seawater Pump Power Output Cable, 2&#215;16 AWG,<br>5 m. Length (20334)<\/figcaption><\/figure>\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"656\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/Cable-11-NMEA-6m.jpg\" alt=\"\" class=\"wp-image-1470\" style=\"width:202px;height:221px\"\/><figcaption class=\"wp-element-caption\">NMEA Drop Cable, 6 m.<br>(30332)<\/figcaption><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"600\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/able-10-D-Code-10-m.jpg\" alt=\"\" class=\"wp-image-1471\" style=\"width:216px;height:216px\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/able-10-D-Code-10-m.jpg 600w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/able-10-D-Code-10-m-150x150.jpg 150w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><figcaption class=\"wp-element-caption\">Ethernet Adapter Cable, D-Code, 10 m.<br>(30330)<\/figcaption><\/figure>\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<p class=\"has-text-align-center has-small-font-size\"><em><strong>Figure 2 \u2013<\/strong> Electrical Equipment for <span translate=\"no\">Seakeeper<\/span> 1<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>This section for electrical installation explains how to mount the electrical equipment and how to connect the electrical cables. Reference Documents &amp; Drawings: The following images show the electrical equipment included with the Seakeeper 1 Hardware Scope of Supply (Drawing No. 90510): Figure 2 \u2013 Electrical Equipment for Seakeeper 1<\/p>\n","protected":false},"author":3,"featured_media":0,"parent":8469,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"manual":[239],"model":[],"document_type":[],"hidden":[],"class_list":["post-8471","page","type-page","status-publish","hentry","manual-seakeeper-1-installation-manual-90519-2"],"acf":[],"_links":{"self":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/8471","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/comments?post=8471"}],"version-history":[{"count":11,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/8471\/revisions"}],"predecessor-version":[{"id":19993,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/8471\/revisions\/19993"}],"up":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/8469"}],"wp:attachment":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/media?parent=8471"}],"wp:term":[{"taxonomy":"manual","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/manual?post=8471"},{"taxonomy":"model","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/model?post=8471"},{"taxonomy":"document_type","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/document_type?post=8471"},{"taxonomy":"hidden","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/hidden?post=8471"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}