{"id":4891,"date":"2021-07-30T15:59:13","date_gmt":"2021-07-30T15:59:13","guid":{"rendered":"https:\/\/manuals.seakeeper.com\/seakeeper-26-20hd-installation-manual-copy\/electrical-installation\/electrical-equipment-power-connections-2\/"},"modified":"2021-10-08T20:36:15","modified_gmt":"2021-10-08T20:36:15","slug":"electrical-equipment-power-connections-2","status":"publish","type":"page","link":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-35-installation-manual\/electrical-installation\/electrical-equipment-power-connections-2\/","title":{"rendered":"Electrical Equipment Power Connections"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" style=\"font-size:25px\">230 VAC Power Source Requirements<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>230 VAC (nominal), 1 Phase, 50\/60 Hz, 30 A<\/li><li>With installations of more than one <span translate=\"no\">Seakeeper<\/span>, a separate circuit breaker should be used for each <span translate=\"no\">Seakeeper<\/span> Motor Drive Box.<\/li><\/ol>\n\n\n\n\n\n<h2 class=\"wp-block-heading\" style=\"font-size:25px\">Drive Box AC Power Input Connection Instructions<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Cable: 3 x 10 AWG (3 x 6 mm<sup>2<\/sup> CSA), 10 ft (3 m) length, <span translate=\"no\">Seakeeper<\/span> supplied pre-installed.<ol><li>Locate Cable 2 for AC power input to the Motor Drive Box at the outward of three cable glands.<br><br><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"419\" class=\"wp-image-4743\" style=\"width: 600px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/SEAKEEPER-26-Motor-Drive-Box-AC-Power-Input-Output-Cable-Glands.jpg\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SEAKEEPER-26-Motor-Drive-Box-AC-Power-Input-Output-Cable-Glands.jpg 990w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SEAKEEPER-26-Motor-Drive-Box-AC-Power-Input-Output-Cable-Glands-768x537.jpg 768w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><br><em><sub><strong>Figure 2 \u2013<\/strong> Motor Drive Box AC Power Input &amp; Output Cable Glands<\/sub><\/em><br><br><br><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"164\" class=\"wp-image-4239\" style=\"width: 500px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/Cable-2-Wire-Connections-at-AC-Power-Distribution-Panel.jpg\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Cable-2-Wire-Connections-at-AC-Power-Distribution-Panel.jpg 868w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Cable-2-Wire-Connections-at-AC-Power-Distribution-Panel-768x252.jpg 768w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><br><em><sub><strong>Figure 3 \u2013 <\/strong>Cable 2 Wire Connections at AC Power Distribution Panel<\/sub><\/em><\/li><li>For <span translate=\"no\">Seakeeper<\/span> 35, connect 230 VAC wires in Cable 2 to a <span class=\"has-inline-color has-vivid-red-color\"><strong>30 A<\/strong><\/span>, double-pole Circuit Breaker at an AC power distribution panel according to Figure 3 above.<\/li><li>For <span translate=\"no\">Seakeeper<\/span> 30HD, connect 230 VAC wires in Cable 2 to a <span class=\"has-inline-color has-vivid-red-color\"><strong>20 A<\/strong><\/span>, double-pole Circuit Breaker at an AC power distribution panel according to Figure 3 above.<\/li><\/ol><\/li><\/ol>\n\n\n\n\n\n<h2 class=\"wp-block-heading\" style=\"font-size:25px\">Drive Box AC Power Output to Seawater Pump Connection Instructions<\/h2>\n\n\n\n<ol class=\"wp-block-list\" start=\"1\"><li>Cable: 3 x 10 AWG (3 x 6 mm<sup>2<\/sup> CSA), 10 ft (3 m) length, <span translate=\"no\">Seakeeper<\/span> supplied pre-installed.<\/li><li>Pumps rated at 230 VAC, 5 A max., Customer-supplied.<br><br><img loading=\"lazy\" decoding=\"async\" width=\"150\" height=\"95\" class=\"wp-image-1505\" style=\"width: 150px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/warning-icon.jpg\" alt=\"\"><strong>Verify that AC power is OFF to the Drive Box before connecting Cable 5 to a Seawater Pump.<\/strong><br><ol><li>Locate Cable 5, for AC power output to the Seawater Pump from the Drive Box at the middle of three cable glands. (See Figure 2.)<br><br><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"193\" class=\"wp-image-5026\" style=\"width: 600px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/SEAKEEPER-35-Cable-5-AC-Output-Power-Cable-1.jpg\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SEAKEEPER-35-Cable-5-AC-Output-Power-Cable-1.jpg 1167w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SEAKEEPER-35-Cable-5-AC-Output-Power-Cable-1-768x247.jpg 768w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><br><em><sub><strong>Figure 4 \u2013<\/strong> Cable 5, AC Output Power Cable<\/sub><\/em><\/li><li>Connect the 230 VAC wires in Cable 5 to a 5 A maximum, Seawater Pump (approximately 1\/3 horsepower or 250 W) according to Figures 4 and 5.<br><br><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"175\" class=\"wp-image-5028\" style=\"width: 600px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/SEAKEEPER-35-Cable-5-Wire-Connections-to-Seawater-Pump.jpg\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SEAKEEPER-35-Cable-5-Wire-Connections-to-Seawater-Pump.jpg 1274w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SEAKEEPER-35-Cable-5-Wire-Connections-to-Seawater-Pump-768x224.jpg 768w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><br><em><sub><strong>Figure 5 \u2013<\/strong> Cable 5, Wire Connections to Seawater Pump<\/sub><\/em><\/li><\/ol><\/li><\/ol>\n\n\n\n<ol class=\"wp-block-list\" start=\"3\"><li>If the customer-supplied Seawater Pump is not rated for 230 VAC, the Cable 5 output may be used to switch a customer-supplied relay.<ol><li>Locate Cable 5 for AC power output to the Seawater Pump from the Drive Box at the middle of three cable glands as shown in Figure 2.<\/li><li>The recommended wiring is shown in Figure 6. Refer to Figure 4 for Cable 5 wire connections.<\/li><\/ol><\/li><\/ol>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/SEAKEEPER-35-Recommended-Wiring-for-Seawater-Pumps-Not-230-VAC.jpg\" alt=\"\" class=\"wp-image-5031\" width=\"757\" height=\"448\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SEAKEEPER-35-Recommended-Wiring-for-Seawater-Pumps-Not-230-VAC.jpg 997w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SEAKEEPER-35-Recommended-Wiring-for-Seawater-Pumps-Not-230-VAC-768x454.jpg 768w\" sizes=\"auto, (max-width: 757px) 100vw, 757px\" \/><figcaption><em><strong>Figure 6 \u2013<\/strong> Recommended Wiring for Seawater Pumps Not 230 VAC<\/em><\/figcaption><\/figure><\/div>\n\n\n\n<ol class=\"wp-block-list\" start=\"4\"><li>If Cable 5 is not used, bundle cable and secure to <span translate=\"no\">Seakeeper<\/span> frame or other area nearby which will not come in contact with moving parts during <span translate=\"no\">Seakeeper<\/span> operation. Do NOT cut Cable 5 as it contains live voltage when <span translate=\"no\">Seakeeper<\/span> is in operation. <span translate=\"no\">Seakeeper<\/span> ships with Cable 5 permanently sealed at end of cable with protective cap in the event it is not used. Do NOT remove Cable 5 from Drive Box as moisture will be free to enter box through open cable gland and corrode internal electronic components<\/li><\/ol>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<div class=\"wp-block-image\"><figure class=\"alignright size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/warning-icon.jpg\" alt=\"\" class=\"wp-image-1505\" width=\"162\" height=\"102\"\/><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p><strong>Cable 5 contains live voltage when <span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span> is in operation. Do<br>NOT cut Cable 5. Do not remove Cable 5 from Drive Box.<\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n\n\n<h2 class=\"wp-block-heading\" style=\"font-size:25px\">24 VDC Power Source Requirements<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>24 VDC, 15 A<\/li><li>A separate breaker should be used for each <span translate=\"no\">Seakeeper<\/span>.<\/li><\/ol>\n\n\n\n\n\n<h2 class=\"wp-block-heading\" style=\"font-size:25px\">DC Power Connection Instructions<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<div class=\"wp-block-image\"><figure class=\"alignright size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/warning-icon.jpg\" alt=\"\" class=\"wp-image-1505\" width=\"159\" height=\"100\"\/><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p><strong>Reversing polarity on the DC power input to the <span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span> can result in damaging the electronics in the control system.<\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<ol class=\"wp-block-list\"><li>24 VDC, 15 A, 2 x 12 AWG (3 x 4 mm<sup>2<\/sup> CSA) <span translate=\"no\">Seakeeper<\/span> supplied.<ol><li>Install <span translate=\"no\">Seakeeper<\/span> provided DC Power Input Cable, P\/N 20248, as Cable 1.<ol><li>Route Cable 1 to DC Power Distribution Panel.<\/li><li>Terminate red conductor to +24 VDC. Terminate black conductor to 24 V Rtn or 0 VDC.<\/li><\/ol><\/li><li>Before connecting Cable 1 to <span translate=\"no\">Seakeeper<\/span>, check for proper voltage and polarity with a DC multimeter using Figure 7 below.<\/li><li>Connect Cable 1 to 24 VDC input receptacle on <span translate=\"no\">Seakeeper<\/span>.<\/li><\/ol><\/li><\/ol>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/DC-Power-Input-Connector-Contact-Assignments-Front.jpg\" alt=\"\" class=\"wp-image-4255\" width=\"290\" height=\"206\"\/><figcaption><em><strong>Figure 7 \u2013 <\/strong>DC Power Input Connector Contact Assignments (front)<\/em><\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<div class=\"wp-block-image\"><figure class=\"alignright size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/warning-icon.jpg\" alt=\"\" class=\"wp-image-1505\" width=\"158\" height=\"100\"\/><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p><strong>When energizing DC power for the first time, if Display does not power up immediately then disconnect and inspect connector polarity.<\/strong><\/p>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>230 VAC Power Source Requirements 230 VAC (nominal), 1 Phase, 50\/60 Hz, 30 A With installations of more than one Seakeeper, a separate circuit breaker should be used for each Seakeeper Motor Drive Box. Drive Box AC Power Input Connection Instructions Cable: 3 x 10 AWG (3 x 6 mm2 CSA), 10 ft (3 m) [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"parent":4885,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"manual":[196],"model":[],"document_type":[],"hidden":[],"class_list":["post-4891","page","type-page","status-publish","hentry","manual-seakeeper-35-installation-manual"],"acf":[],"_links":{"self":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/4891","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/comments?post=4891"}],"version-history":[{"count":9,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/4891\/revisions"}],"predecessor-version":[{"id":7357,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/4891\/revisions\/7357"}],"up":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/4885"}],"wp:attachment":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/media?parent=4891"}],"wp:term":[{"taxonomy":"manual","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/manual?post=4891"},{"taxonomy":"model","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/model?post=4891"},{"taxonomy":"document_type","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/document_type?post=4891"},{"taxonomy":"hidden","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/hidden?post=4891"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}