{"id":22143,"date":"2026-08-04T11:11:15","date_gmt":"2026-08-04T11:11:15","guid":{"rendered":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-10-installation-manual-90841-3-10-262-0712-to-current-copy\/electrical-installation\/electrical-equipment-power-connections-2\/"},"modified":"2026-10-27T13:26:11","modified_gmt":"2026-10-27T13:26:11","slug":"electrical-equipment-power-connections-2","status":"publish","type":"page","link":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-10-installation-manual-90841-4\/electrical-installation\/electrical-equipment-power-connections-2\/","title":{"rendered":"3.2  Electrical Equipment Power Connections"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" style=\"font-size:25px\">230 VAC Power Source Requirements<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>230 VAC (nominal), 1 Phase, 50\/60 Hz, 30 A<\/li>\n\n\n\n<li>For installations of more than one <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span>, a separate circuit breaker should be used for each <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> Motor Drive Box.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator is-style-wide\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Spool-Up Power Modes<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The <span translate=\"no\">Seakeeper<\/span> 10.5 is factory-configured for Default Spool mode, which accelerates the flywheel to operating speed (8700 RPM) in 40 minutes. This mode requires a higher AC power draw during startup (4000 W) but reduces the overall startup duration. For vessels with limited generator capacity or where minimizing peak electrical load is preferred, an optional Low-Power Spool mode can be selected on the display&#8217;s Settings page. This mode reduces the startup power demand to only 3500 W, which increases the time required for the flywheel to reach operating speed. Select the spool mode appropriate for the vessel&#8217;s electrical system to ensure reliable operation without overloading the AC power source.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" style=\"font-size:25px\">Drive Box AC Power Input Connection Instructions<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>230 VAC Input Cable: 3 x 10 AWG (3 x 6 mm<sup>2<\/sup> CSA), 10 ft. (3 m) length, <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> supplied pre-installed.<br>\n<ol class=\"wp-block-list\">\n<li>Locate 230 VAC Input Cable for AC power input to the Drive Box at the outboard of the Motor Drive Box cable glands.<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"2794\" height=\"1911\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/MDB.png\" alt=\"\" class=\"wp-image-18292\" style=\"width:447px;height:auto\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/MDB.png 2794w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/MDB-768x525.png 768w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/MDB-1536x1051.png 1536w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/MDB-2048x1401.png 2048w\" sizes=\"auto, (max-width: 2794px) 100vw, 2794px\" \/><figcaption class=\"wp-element-caption\"><strong><em>Figure 19<\/em><\/strong><em> &#8211; Drive Box AC Power Input and Motor Output Glands<\/em><\/figcaption><\/figure>\n<\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"346\" height=\"114\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Picture5.jpg\" alt=\"\" class=\"wp-image-10424\" style=\"width:438px;height:144px\"\/><figcaption class=\"wp-element-caption\"><strong><em>Figure 20<\/em><\/strong><em> &#8211; 230 VAC Input Cable Wire <\/em><br><em>Connections at AC Power Distribution Panel<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<ol start=\"2\" class=\"wp-block-list\">\n<li>Connect 230 VAC Input Cable wires to a 30 A, double-pole Circuit Breaker at an AC power distribution panel according to Figure 20 above.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator is-style-wide\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" style=\"font-size:25px\">24 VDC Power Source Requirements<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> Control Power: one 24 VDC, 10 A (Customer supplied), <strong>AND<\/strong><\/li>\n\n\n\n<li>Seawater Pump: one 24 VDC, 10 A<sup>*<\/sup> Max (Customer supplied), seawater pump dependent.<\/li>\n\n\n\n<li>A separate breakers should be used for each <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> in multiple <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> installations.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">* Alternate seawater pump configuration  for customer-supplied DC-powered seawater pump, 24 VDC at 20 A maximum.<\/p>\n\n\n\n<hr class=\"wp-block-separator is-style-wide\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" style=\"font-size:25px\">DC Power Connection Instructions<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\"><div class=\"wp-block-image\">\n<figure class=\"alignright size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"253\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/warning-icon.jpg\" alt=\"\" class=\"wp-image-1505\" style=\"width:159px;height:100px\"\/><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"has-vivid-red-color has-text-color wp-block-paragraph\"><strong>Reversing polarity on the DC power input to the <span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span> can result in damaging the electronics in the control system.<\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<ol class=\"wp-block-list\">\n<li>24 VDC, 10 A, 2 x 12 AWG (3 x 4.0 mm<sup>2<\/sup> CSA) customer supplied.<br>\n<ol class=\"wp-block-list\">\n<li>Install <span translate=\"no\"><span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span><\/span> provided DC Power Input Cable, P\/N 20248 (as shown in <strong>Drawing No. 90719<\/strong>).<br>\n<ol class=\"wp-block-list\">\n<li>Route 24 VDC Power Cable to DC Power Distribution Panel.<\/li>\n\n\n\n<li>Terminate positive (B+, Red ) conductor to +24 VDC. <\/li>\n\n\n\n<li>Terminate negative (B-, Black) conductor directly to battery negative terminal.<\/li>\n<\/ol>\n<\/li>\n\n\n\n<li>Before connecting cable to <span translate=\"no\"><span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span><\/span>, check for proper voltage and polarity with a DC multimeter using Figure 21 below.<\/li>\n\n\n\n<li>Connect 24 VDC Input Cable to 24 VDC input receptacle on <span translate=\"no\"><span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span><\/span>.<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"627\" height=\"447\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/DC-Power-Input-Connector-Contact-Assignments-Front.jpg\" alt=\"\" class=\"wp-image-4255\" style=\"width:290px;height:206px\"\/><figcaption class=\"wp-element-caption\"><em><strong>Figure 21 \u2013 <\/strong>DC Power Input Connector Contact Assignments (front)<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<hr class=\"wp-block-separator is-style-wide\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">DC Seawater Pump 24 VDC Power Input Connection Instructions<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\"><div class=\"wp-block-image\">\n<figure class=\"alignright size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"406\" height=\"358\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/CAUTION.png\" alt=\"\" class=\"wp-image-10247\" style=\"width:119px;height:105px\"\/><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"has-vivid-red-color has-text-color wp-block-paragraph\"><strong>Connecting the DC Seawater pump in any other manner than recommended by <span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span> may cause internal failure.<\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<ol style=\"list-style-type:1\" class=\"wp-block-list\">\n<li>Install Seawater Pump Input Cable (P\/N 20454) to <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> 10.5 \u201cSW Pump VDC In\u201d (as shown in <strong>Drawing No. 90719<\/strong>) with overcurrent protection corresponding to seawater pump selected.<\/li>\n\n\n\n<li>Connect the 14 AWG positive conductor (Red) through dedicated overcurrent protection device (customer supplied), 10 A (20 A maximum), to dedicated battery isolation switch.<\/li>\n\n\n\n<li>Connect the 14 AWG negative conductor (Black) directly to battery negative terminal or DC main negative bus bar.<\/li>\n\n\n\n<li>Before connecting Seawater Pump Input Cable to <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span>, check for proper voltage and polarity with a DC multimeter using Figure 8 below.<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"213\" height=\"148\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Figure-5.png\" alt=\"\" class=\"wp-image-9376\" style=\"width:377px;height:262px\"\/><figcaption class=\"wp-element-caption\"><em><strong>Figure 22<\/strong> &#8211; 24 VDC Seawater Pump Power Input<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<ol start=\"5\" class=\"wp-block-list\">\n<li>Connect Seawater Pump Input Cable to Seawater Pump 24 VDC In connector on the <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span>, DEUTSCH DT04-2P connector.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator is-style-wide\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">DC Seawater Pump 24 VDC Power Output Connection Instructions<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Connect Seawater Pump Output Cable (P\/N 20455) to the <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> 10.5 \u201cSW Pump VDC Out\u201d for DC power to the seawater pump.<br>\n<ol class=\"wp-block-list\">\n<li>Seawater Pump Output Cable (P\/N 20455) is a 2 x 14 AWG cable, 16 ft (5 m) length with a size 14 female Deutsch plug.<\/li>\n<\/ol>\n<\/li>\n\n\n\n<li>Pumps rated at 24 VDC, 10 A maximum, customer-supplied, must be configured with a Deutsch<br>DTP04-2P, 2-pin receptacle to mate with the connector shown in Figure 23.<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1881\" height=\"1113\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/DTP06-2S.png\" alt=\"\" class=\"wp-image-18295\" style=\"width:432px;height:auto\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/DTP06-2S.png 1881w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/DTP06-2S-768x454.png 768w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/DTP06-2S-1536x909.png 1536w\" sizes=\"auto, (max-width: 1881px) 100vw, 1881px\" \/><figcaption class=\"wp-element-caption\"><strong><em>Figure 23 <\/em><\/strong><em>&#8211; Seawater Pump Deutsch Connector<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<ol start=\"3\" style=\"list-style-type:1\" class=\"wp-block-list\">\n<li>Seawater Pump Output Cable must be routed and installed in the vessel from the <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> 10.5 \u201cSW Pump VDC Out\u201d Deutsch connector (pins end) to the customer-supplied receptacle of the DC seawater pump. The recommended wiring is shown in Figure 24.<\/li>\n\n\n\n<li>Contact <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> if desired to install customer-supplied relay on Seawater Pump Output Cable to power seawater pump.<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"853\" height=\"251\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Seawater-Cable-w-o-Valve.png\" alt=\"\" class=\"wp-image-21704\" style=\"object-fit:cover;width:666px;height:200px\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Seawater-Cable-w-o-Valve.png 853w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Seawater-Cable-w-o-Valve-768x226.png 768w\" sizes=\"auto, (max-width: 853px) 100vw, 853px\" \/><figcaption class=\"wp-element-caption\"><strong><em>Figure 24<\/em><\/strong><em> &#8211; 24 VDC SW Pump Schematic<\/em><\/figcaption><\/figure>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>230 VAC Power Source Requirements Spool-Up Power Modes The Seakeeper 10.5 is factory-configured for Default Spool mode, which accelerates the flywheel to operating speed (8700 RPM) in 40 minutes. This mode requires a higher AC power draw during startup (4000 W) but reduces the overall startup duration. For vessels with limited generator capacity or where [&hellip;]<\/p>\n","protected":false},"author":9,"featured_media":0,"parent":22139,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"manual":[383],"model":[],"document_type":[],"hidden":[],"class_list":["post-22143","page","type-page","status-publish","hentry","manual-seakeeper-10-installation-manual-90841-4"],"acf":[],"_links":{"self":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/22143","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/comments?post=22143"}],"version-history":[{"count":2,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/22143\/revisions"}],"predecessor-version":[{"id":22846,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/22143\/revisions\/22846"}],"up":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/22139"}],"wp:attachment":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/media?parent=22143"}],"wp:term":[{"taxonomy":"manual","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/manual?post=22143"},{"taxonomy":"model","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/model?post=22143"},{"taxonomy":"document_type","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/document_type?post=22143"},{"taxonomy":"hidden","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/hidden?post=22143"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}