{"id":21491,"date":"2026-06-15T16:02:24","date_gmt":"2026-06-15T16:02:24","guid":{"rendered":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-4-4-5-installation-manual-90762-1-copy\/6-0-installation-and-start-up-checklist\/6-2-installation-checklist\/"},"modified":"2026-07-15T12:48:44","modified_gmt":"2026-07-15T12:48:44","slug":"6-2-installation-checklist","status":"publish","type":"page","link":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-5-installation-manual\/6-0-installation-and-start-up-checklist\/6-2-installation-checklist\/","title":{"rendered":"6.2  Installation Checklist"},"content":{"rendered":"\n<h3 class=\"wp-block-heading\">6.2.1  Mechanical Checklist<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" width=\"25\" height=\"24\" class=\"wp-image-9567\" style=\"width: 25px;\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png 156w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark-150x149.png 150w\" sizes=\"auto, (max-width: 25px) 100vw, 25px\" \/> <span translate=\"no\">Seakeeper<\/span> foundation installed per requirements of Drawing No. 90726 \u2013 <br> <span translate=\"no\">Seakeeper<\/span> 4, 4.5, &amp; 5 Bolt-In Installation Details.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Structure designed to accommodate <span translate=\"no\">Seakeeper<\/span> 5 forces, as defined in<br> Drawing 90726 &#8211; <span translate=\"no\">Seakeeper<\/span> 4, 4.5, &amp; 5 Bolt-In Details, with a minimum safety<br> factor of 2.0.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">          Foundation is coplanar within 0.06 in. (1.5 mm).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" width=\"25\" height=\"24\" class=\"wp-image-9567\" style=\"width: 25px;\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png 156w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark-150x149.png 150w\" sizes=\"auto, (max-width: 25px) 100vw, 25px\" \/>  Clearances around <span translate=\"no\">Seakeeper<\/span> meet service and operating specifications<br>        and no obstructions are within the <span translate=\"no\">Seakeeper<\/span> envelope.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" width=\"25\" height=\"24\" class=\"wp-image-9567\" style=\"width: 25px;\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png 156w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark-150x149.png 150w\" sizes=\"auto, (max-width: 25px) 100vw, 25px\" \/> <span translate=\"no\">Seakeeper<\/span> 4, 4.5, &amp; 5 Bolt-In Kit is installed (P\/N 90804 &#8211; Blind Hole Installation) (P\/N 90805 &#8211; Thru-Hole Installation).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" width=\"25\" height=\"24\" class=\"wp-image-9567\" style=\"width: 25px;\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png 156w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark-150x149.png 150w\" sizes=\"auto, (max-width: 25px) 100vw, 25px\" \/> Foundation bolts torqued to specification: 155 ft-lbs (210 Nm).<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">6.2.2  Electrical Checklist<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" width=\"25\" height=\"24\" class=\"wp-image-9567\" style=\"width: 25px;\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png 156w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark-150x149.png 150w\" sizes=\"auto, (max-width: 25px) 100vw, 25px\" \/>  <strong>Ground Cable<\/strong> (Customer Supplied) ground cable connected on both ends.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" width=\"25\" height=\"24\" class=\"wp-image-9567\" style=\"width: 25px;\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png 156w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark-150x149.png 150w\" sizes=\"auto, (max-width: 25px) 100vw, 25px\" \/>  <strong>12 VDC Control Power Cable<\/strong> (<span translate=\"no\">Seakeeper<\/span> Supplied) <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">          Connect wire end to 12 VDC power at customer-supplied connection<br>          box or directly to circuit breaker.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">          Plug connector of Cable 1 into mating connector on <span translate=\"no\">Seakeeper<\/span> wire<br>          harness (INPUT POWER).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" width=\"25\" height=\"24\" class=\"wp-image-9567\" style=\"width: 25px;\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png 156w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark-150x149.png 150w\" sizes=\"auto, (max-width: 25px) 100vw, 25px\" \/>  <strong>Seawater Pump Input Power Cable<\/strong> (<span translate=\"no\">Seakeeper<\/span> Supplied)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">          Connect wire end to 12 VDC power at customer-supplied connection<br>          box or directly to circuit breaker.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Plug connector of DC SW Pump Input cable into mating connector on <span translate=\"no\">Seakeeper<\/span> wire<br> harness (SW PUMP VDC IN).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" width=\"25\" height=\"24\" class=\"wp-image-9567\" style=\"width: 25px;\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png 156w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark-150x149.png 150w\" sizes=\"auto, (max-width: 25px) 100vw, 25px\" \/>  <strong>Seawater Pump Output Cable<\/strong> (<span translate=\"no\">Seakeeper<\/span> Supplied)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Connect DC SW Pump Output cable from SW PUMP VDC OUT to customer-supplied<br> 12 VDC seawater pump.<br><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>SEAKEEPER DISPLAY CONNECTION<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" width=\"25\" height=\"24\" class=\"wp-image-9567\" style=\"width: 25px;\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png 156w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark-150x149.png 150w\" sizes=\"auto, (max-width: 25px) 100vw, 25px\" \/> Ensure a compatible MFD installed (refer to <span translate=\"no\">Seakeeper<\/span> MFD Compatibility<br>          Technical Bulletins)<br><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>NMEA 2000 NETWORK CONENCTION<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" width=\"25\" height=\"24\" class=\"wp-image-9567\" style=\"width: 25px;\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png 156w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark-150x149.png 150w\" sizes=\"auto, (max-width: 25px) 100vw, 25px\" \/>  Required GPS signal on NMEA 2000 backbone<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" width=\"25\" height=\"24\" class=\"wp-image-9567\" style=\"width: 25px;\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png 156w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark-150x149.png 150w\" sizes=\"auto, (max-width: 25px) 100vw, 25px\" \/>  Connect <strong>NMEA CAN Cable<\/strong> to ConnectBox NMEA port.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" width=\"25\" height=\"24\" class=\"wp-image-9567\" style=\"width: 25px;\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png 156w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark-150x149.png 150w\" sizes=\"auto, (max-width: 25px) 100vw, 25px\" \/>  Connect <strong>NMEA CAN Cable<\/strong> to vessel NMEA backbone.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">6.2.3  Cooling Checklist<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" width=\"25\" height=\"24\" class=\"wp-image-9567\" style=\"width: 25px;\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png 156w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark-150x149.png 150w\" sizes=\"auto, (max-width: 25px) 100vw, 25px\" \/> Install 12 VDC seawater pump capable of required flow rates.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">          Optional seawater pump can be purchased through <span translate=\"no\">Seakeeper<\/span> (P\/N 30331)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" width=\"25\" height=\"24\" class=\"wp-image-9567\" style=\"width: 25px;\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png 156w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark-150x149.png 150w\" sizes=\"auto, (max-width: 25px) 100vw, 25px\" \/> Route and connect seawater inlet and outlet hoses per 909482 &#8211; <span translate=\"no\">Seakeeper<\/span> 5<br> Cooling Water Schematic.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" width=\"25\" height=\"24\" class=\"wp-image-9567\" style=\"width: 25px;\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png 156w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark-150x149.png 150w\" sizes=\"auto, (max-width: 25px) 100vw, 25px\" \/>  Test seawater pump with Seawater Override<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Verify 2 GPM (7.5 LPM) minimum and 4 GPM (15.1 LPM) maximum flow rate.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" width=\"25\" height=\"24\" class=\"wp-image-9567\" style=\"width: 25px;\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png 156w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark-150x149.png 150w\" sizes=\"auto, (max-width: 25px) 100vw, 25px\" \/>  Verify coolant level at bottom of filler neck in reservoir.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>6.2.1 Mechanical Checklist Seakeeper foundation installed per requirements of Drawing No. 90726 \u2013 Seakeeper 4, 4.5, &amp; 5 Bolt-In Installation Details. Structure designed to accommodate Seakeeper 5 forces, as defined in Drawing 90726 &#8211; Seakeeper 4, 4.5, &amp; 5 Bolt-In Details, with a minimum safety factor of 2.0. Foundation is coplanar within 0.06 in. (1.5 [&hellip;]<\/p>\n","protected":false},"author":9,"featured_media":0,"parent":21487,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"manual":[375],"model":[],"document_type":[],"hidden":[],"class_list":["post-21491","page","type-page","status-publish","hentry","manual-seakeeper-5-installation-manual"],"acf":[],"_links":{"self":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/21491","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/comments?post=21491"}],"version-history":[{"count":3,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/21491\/revisions"}],"predecessor-version":[{"id":21821,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/21491\/revisions\/21821"}],"up":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/21487"}],"wp:attachment":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/media?parent=21491"}],"wp:term":[{"taxonomy":"manual","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/manual?post=21491"},{"taxonomy":"model","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/model?post=21491"},{"taxonomy":"document_type","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/document_type?post=21491"},{"taxonomy":"hidden","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/hidden?post=21491"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}