{"id":21324,"date":"2026-03-31T12:33:38","date_gmt":"2026-03-31T12:33:38","guid":{"rendered":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-6-installation-manual-90402-6-6-254-8146-to-current-copy\/electrical-installation\/electrical-equipment-power-connections-2\/"},"modified":"2026-08-24T11:26:59","modified_gmt":"2026-08-24T11:26:59","slug":"electrical-equipment-power-connections-2","status":"publish","type":"page","link":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-7-5-installation-manual\/electrical-installation\/electrical-equipment-power-connections-2\/","title":{"rendered":"3.2   Electrical Equipment Power Connections"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" style=\"font-size:25px\">AC Input Power Source Requirements<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Either of two AC input voltages are acceptable:<br>\n<ol class=\"wp-block-list\">\n<li>110 &#8211; 120 VAC (nominal) (+\/- 10%), 1 Phase, 50\/60 Hz, 30 A<\/li>\n\n\n\n<li>208 &#8211; 230 VAC (nominal) (+\/- 10%), 1 Phase, 50\/60 Hz, 30 A<\/li>\n<\/ol>\n<\/li>\n\n\n\n<li>A separate circuit breaker should be used for each <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> drive in multiple <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> installations.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator is-style-wide\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Spool-Up Power Modes<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The <span translate=\"no\">Seakeeper<\/span> 7.5 is factory-configured for Default Spool mode, which accelerates the flywheel to operating speed (9700 RPM) in 24 minutes. This mode requires a higher AC power draw during startup (4000 W) but reduces the overall startup duration. For vessels with limited generator capacity or where minimizing peak electrical load is preferred, an optional Low-Power Spool mode can be selected on the display&#8217;s Settings page. This mode reduces the startup power demand to only 2300 W, which increases the time required for the flywheel to reach operating speed. Select the spool mode appropriate for the vessel&#8217;s electrical system to ensure reliable operation without overloading the AC power source.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" style=\"font-size:25px\">Drive Box AC Power Input Connection Instructions<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Cable: 3 x 10 AWG (3 x 6mm<sup>2<\/sup> CSA), 10 ft (3 m) length, <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> supplied pre-installed.<br>\n<ol class=\"wp-block-list\">\n<li>Locate AC Power Input Cable to the Drive at the outward of two cable glands per Figure 17.<\/li>\n\n\n\n<li>Connect AC wires to a 230 V, 30 A (<strong>or<\/strong> 110 V, 30 A), double-pole Circuit Breaker at an AC power distribution panel.<br><br><\/li>\n<\/ol>\n<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"2794\" height=\"1911\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/MDB.png\" alt=\"\" class=\"wp-image-18292\" style=\"width:554px;height:364px\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/MDB.png 2794w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/MDB-768x525.png 768w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/MDB-1536x1051.png 1536w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/MDB-2048x1401.png 2048w\" sizes=\"auto, (max-width: 2794px) 100vw, 2794px\" \/><figcaption class=\"wp-element-caption\"><em><sub><strong>Figure 17 <em><strong>\u2013<\/strong><\/em><\/strong> Drive Box AC Power Input &amp; Output Cable Glands<\/sub><\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<hr class=\"wp-block-separator is-style-wide\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" style=\"font-size:25px\">12 V Power Input<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>One 12 VDC, 10 A (Customer supplied) for <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> Control Power, <strong>AND<\/strong><\/li>\n\n\n\n<li>One 12 VDC, 15 A (Customer supplied) for the DC Seawater Pump.<\/li>\n\n\n\n<li>A dedicated breaker should be used for <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> control and Seawater Pump power for each <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> unit.<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"2057\" height=\"1503\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/7.5-harness-connections.png\" alt=\"\" class=\"wp-image-22594\" style=\"width:568px;height:294px\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/7.5-harness-connections.png 2057w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/7.5-harness-connections-768x561.png 768w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/7.5-harness-connections-1536x1122.png 1536w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/7.5-harness-connections-2048x1496.png 2048w\" sizes=\"auto, (max-width: 2057px) 100vw, 2057px\" \/><figcaption class=\"wp-element-caption\"><strong><em>Figure 18 &#8211;<\/em><\/strong><em> Wire harness DC connections shown<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<hr class=\"wp-block-separator is-style-wide\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" style=\"font-size:25px\"><span translate=\"no\">Seakeeper<\/span> DC Control Power Connection Instructions<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\"><div class=\"wp-block-image\">\n<figure class=\"alignright size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"406\" height=\"358\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/CAUTION.png\" alt=\"\" class=\"wp-image-10247\" style=\"width:102px;height:90px\"\/><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p class=\"has-vivid-red-color has-text-color wp-block-paragraph\"><br><strong>Reversing polarity on the DC power input to the <span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span> can result in damaging the electronics in the control system.<\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<ol class=\"wp-block-list\">\n<li>12 VDC, 10 A, 2 x 12 AWG (3 x 4 mm<sup>2<\/sup> CSA) customer supplied.<br>\n<ol class=\"wp-block-list\">\n<li>Install <span translate=\"no\"><span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span><\/span> provided DC Power Input Cable, P\/N 20248 (shown in <strong>Drawing No.<\/strong><em>90951<\/em>):<br>\n<ol class=\"wp-block-list\">\n<li>Route DC Power Input Cable to DC Power Distribution Panel.<\/li>\n\n\n\n<li>Terminate positive (B+, Red) conductor through dedicated over-current protection device (customer supplied) and a dedicated <span translate=\"no\"><span translate=\"no\"><span translate=\"no\"><span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span><\/span><\/span><\/span> isolation switch (customer supplied) then directly to battery plus terminal. <\/li>\n\n\n\n<li>Terminate negative (B-, Black) conductor directly to battery negative terminal or negative bus.<\/li>\n<\/ol>\n<\/li>\n\n\n\n<li>Before connecting DC Power Input Cable to <span translate=\"no\"><span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span><\/span>, check for proper voltage and polarity with a DC multimeter using Figure 19.<\/li>\n\n\n\n<li>Connect DC Power Input Cable to 12 VDC input receptacle on <span translate=\"no\"><span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span><\/span>.<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"652\" height=\"455\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/Seakeeper-6-DC-Power-Input-Connector-Contact-Assignments-Front.jpg\" alt=\"\" class=\"wp-image-2737\" style=\"width:286px;height:200px\"\/><figcaption class=\"wp-element-caption\"><em><strong>Figure 19 <em><strong>\u2013<\/strong><\/em> <\/strong>DC Power Input Connector (Deutsch DTP04-2P) Contact Assignments (front)<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\"><div class=\"wp-block-image\">\n<figure class=\"alignright size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"406\" height=\"358\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/CAUTION.png\" alt=\"\" class=\"wp-image-10247\" style=\"width:102px;height:90px\"\/><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p class=\"has-vivid-red-color has-text-color wp-block-paragraph\"><strong>When energizing DC power the first time, if ConnectBox does not power up immediately then disconnect and inspect connector polarity.<\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator is-style-wide\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">DC Seawater Pump 12 VDC Power Input Connection Instructions<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\"><div class=\"wp-block-image\">\n<figure class=\"alignright size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"406\" height=\"358\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/CAUTION.png\" alt=\"\" class=\"wp-image-10247\" style=\"width:102px;height:90px\"\/><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p class=\"has-vivid-red-color has-text-color has-link-color wp-elements-1 wp-block-paragraph\"> <br><strong>Connecting the DC Seawater pump in any other manner than recommended by <span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span> may cause internal failure.<\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Install DC SW Pump Input Power Cable (P\/N: 20454) to <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> 7.5 \u201cSW Pump DC In\u201d (shown in <strong>Drawing No.<\/strong> <em>90951<\/em>) with overcurrent protection corresponding to seawater pump selected.<\/li>\n\n\n\n<li>Connect the 14 AWG positive conductor (red) through dedicated overcurrent protection device (customer-supplied), maximum of 15 A, to dedicated battery isolation switch.<\/li>\n\n\n\n<li>Connect the 14 AWG negative conductor (black) directly to battery negative terminal or DC main negative bus bar.<\/li>\n\n\n\n<li>Before connecting DC SW Pump Input Power Cable to <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span>, check for proper voltage and polarity with a DC multimeter using Figure 20.<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"213\" height=\"148\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/Figure-5.png\" alt=\"\" class=\"wp-image-9376\" style=\"width:253px;height:176px\"\/><figcaption class=\"wp-element-caption\"><strong><em>Figure 20<\/em> &#8211; <\/strong><em>12 VDC Seawater Pump Power Input<\/em> <br>(Deutsch DTP04-2P)<\/figcaption><\/figure>\n<\/div>\n\n\n<ol start=\"5\" class=\"wp-block-list\">\n<li>Connect DC SW Pump Power Input Cable to Seawater Pump 12 VDC In connector on the <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span>, DEUTSCH DT04-2P connector.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator is-style-wide\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" style=\"font-size:25px\">DC Seawater Pump 12 VDC Power Output Connection Instructions<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Connect DC SW Pump Power Output Cable (P\/N 20455) to the <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> 7.5 wire harness connector \u201cSW Pump 12VDC Out\u201d female connector for DC power output to the seawater pump.<br>\n<ol class=\"wp-block-list\">\n<li>Seawater Pump Output Power Cable is a 2 x 14 AWG cable, 16 ft (5 m) length, with a size 14 female Deutsch plug.<\/li>\n<\/ol>\n<\/li>\n\n\n\n<li>Pumps rated at 12 VDC, 15 A maximum, customer-supplied, must be configured with a Deutsch DTP series, 2-pin receptacle to mate with the connector shown in Figure 21.<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"656\" height=\"441\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/DTP06-2S-SW-PP-OUT-on-harness.png\" alt=\"\" class=\"wp-image-22602\" style=\"width:444px;height:274px\"\/><figcaption class=\"wp-element-caption\"><strong><em>Figure 21<\/em><\/strong> <strong>&#8211;<\/strong> <em>Seawater Pump Female Connector<\/em> <br>(<em>Deutsch DTP06-2S<\/em>)<\/figcaption><\/figure>\n<\/div>\n\n\n<ol start=\"3\" class=\"wp-block-list\">\n<li>The DC SW Pump Power Output Cable must be routed and installed in the vessel from the <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> 7.5 \u201cSW Pump 12VDC Out\u201d Deutsch connector (pins end) to the customer-supplied seawater pump per Figure 22.<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"940\" height=\"239\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Seawater-Cable.png\" alt=\"\" class=\"wp-image-21382\" style=\"width:732px;height:auto\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Seawater-Cable.png 940w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Seawater-Cable-768x195.png 768w\" sizes=\"auto, (max-width: 940px) 100vw, 940px\" \/><figcaption class=\"wp-element-caption\"><strong><em>Figure 22 <\/em>&#8211;<\/strong> <em>DC SW Pump Power Output Cable with the Seawater Pump<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>AC Input Power Source Requirements Spool-Up Power Modes The Seakeeper 7.5 is factory-configured for Default Spool mode, which accelerates the flywheel to operating speed (9700 RPM) in 24 minutes. This mode requires a higher AC power draw during startup (4000 W) but reduces the overall startup duration. For vessels with limited generator capacity or where [&hellip;]<\/p>\n","protected":false},"author":9,"featured_media":0,"parent":21320,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"manual":[373],"model":[],"document_type":[],"hidden":[],"class_list":["post-21324","page","type-page","status-publish","hentry","manual-seakeeper-7-5-installation-manual"],"acf":[],"_links":{"self":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/21324","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/comments?post=21324"}],"version-history":[{"count":9,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/21324\/revisions"}],"predecessor-version":[{"id":22811,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/21324\/revisions\/22811"}],"up":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/21320"}],"wp:attachment":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/media?parent=21324"}],"wp:term":[{"taxonomy":"manual","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/manual?post=21324"},{"taxonomy":"model","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/model?post=21324"},{"taxonomy":"document_type","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/document_type?post=21324"},{"taxonomy":"hidden","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/hidden?post=21324"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}