{"id":21011,"date":"2025-11-13T15:57:45","date_gmt":"2025-11-13T15:57:45","guid":{"rendered":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-40-installation-manual-90715-3-40-244-0121-to-current-copy\/installation-checklist-and-supplies\/required-supplies-needed-for-seakeeper-installation\/"},"modified":"2025-12-03T13:54:42","modified_gmt":"2025-12-03T13:54:42","slug":"required-supplies-needed-for-seakeeper-installation","status":"publish","type":"page","link":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-40-installation-manual-90715-4-40-254-0200-to-current\/installation-checklist-and-supplies\/required-supplies-needed-for-seakeeper-installation\/","title":{"rendered":"6.2  Installation Checklist"},"content":{"rendered":"\n<p class=\"has-text-align-center has-medium-font-size\"><strong>Please Complete Checklist and E-mail to <\/strong><a href=\"mailto:support@seakeeper.com\" target=\"_blank\" rel=\"noreferrer noopener\">support@seakeeper.com<\/a> or <a href=\"mailto:emeasupport@seakeeper.com\">emeasupport@seakeeper.com<\/a> (outside of the Americas).<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"block-1ca82cd6-97cd-4e60-afb8-756507e70ead\" style=\"font-size:25px\">Mechanical Checklist<br>(Reference Installation Manual Section: Mechanical Installation)<\/h2>\n\n\n\n<p><img decoding=\"async\" style=\"width: 40px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/Check-mark.png\" alt=\"\">   <span translate=\"no\">Seakeeper<\/span> foundation installed in hull<\/p>\n\n\n\n<p><img decoding=\"async\" style=\"width: 40px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/Check-mark.png\" alt=\"\">   Foundation bolts torqued to specification<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"block-b292c5c6-87fc-4342-ba39-879dcd4cffcb\" style=\"font-size:25px\">Electrical Checklist<br>(Reference <span translate=\"no\">Seakeeper<\/span> Drawing No. 90710 \u2013 <span translate=\"no\">Seakeeper<\/span> 40 Cable Block Diagram &amp; Installation Manual Section: Electrical Installation)<\/h2>\n\n\n\n<p class=\"has-medium-font-size\"><strong>Mount Components<\/strong><\/p>\n\n\n\n<p><img decoding=\"async\" style=\"width: 40px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/Check-mark.png\" alt=\"\">   Multifunction Display (at helm)<\/p>\n\n\n\n<p><img decoding=\"async\" style=\"width: 40px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/Check-mark.png\" alt=\"\">   Remote ConnectBox mounting:  ______________________ (location)<\/p>\n\n\n\n<p class=\"has-medium-font-size\"><strong>Connect Customer Supplied Cables<\/strong><\/p>\n\n\n\n<p>Ground Cable (Customer Supplied)<br><\/p>\n\n\n\n<p><img decoding=\"async\" style=\"width: 40px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/Check-mark.png\" alt=\"\">    Install lugs on both ends of customer-supplied 10 AWG ground cable<\/p>\n\n\n\n<p><img decoding=\"async\" style=\"width: 40px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/Check-mark.png\" alt=\"\">    Connect one end of Ground Cable to nearest vessel ground and other end to <span translate=\"no\">Seakeeper<\/span> foundation frame<\/p>\n\n\n\n<p class=\"has-medium-font-size\"><strong>Connect <span translate=\"no\">Seakeeper<\/span> Supplied Cables<\/strong><\/p>\n\n\n\n<p>DC Input Power Cable (<span translate=\"no\">Seakeeper<\/span> supplied)<\/p>\n\n\n\n<p><img decoding=\"async\" style=\"width: 40px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/Check-mark.png\" alt=\"\">    Connect the DC Input Power Cable from <span translate=\"no\">Seakeeper<\/span> to 24 VDC power at customer-supplied connection box or directly to circuit breaker<\/p>\n\n\n\n<p><img decoding=\"async\" style=\"width: 40px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/Check-mark.png\" alt=\"\">    Plug connector of DC Input Power Cable into mating connector on <span translate=\"no\">Seakeeper<\/span> wire harness<\/p>\n\n\n\n<p>AC Power Input Cable (<span translate=\"no\">Seakeeper<\/span> Supplied)<\/p>\n\n\n\n<p><img decoding=\"async\" style=\"width: 40px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/Check-mark.png\" alt=\"\">    Connect the AC Power Input Cable from Drive Box to 230 VAC single phase at customer-supplied connection box or directly to circuit breaker<\/p>\n\n\n\n<p>CAN Communication Assembly (<span translate=\"no\">Seakeeper<\/span> Supplied)<\/p>\n\n\n\n<p><img decoding=\"async\" style=\"width: 40px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/Check-mark.png\" alt=\"\">    Connect female end of CAN communications Cable to mating connector on <span translate=\"no\">Seakeeper<\/span> wire harness<\/p>\n\n\n\n<p><img decoding=\"async\" style=\"width: 40px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/Check-mark.png\" alt=\"\">    Route CAN communications Cable from <span translate=\"no\">Seakeeper<\/span> to helm (male end goes to helm)<\/p>\n\n\n\n<p><img decoding=\"async\" style=\"width: 40px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/Check-mark.png\" alt=\"\">    Connect male end of CAN communications Cable at helm to CAN Tee Adapter<\/p>\n\n\n\n<p><img decoding=\"async\" style=\"width: 40px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/Check-mark.png\" alt=\"\">    Connect Display and <span translate=\"no\">Seakeeper<\/span>-supplied 24 in. (0.6 m) cable to CAN Tee Adapter with CAN Terminator<\/p>\n\n\n\n<p>Seawater Pump Power Output Cable (<span translate=\"no\">Seakeeper<\/span> Supplied)<\/p>\n\n\n\n<p><img decoding=\"async\" style=\"width: 40px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/Check-mark.png\" alt=\"\">    Connect Seawater Pump Power Output Cable from <span translate=\"no\">Seakeeper<\/span> wire harness to customer-supplied 24 VDC seawater pump<\/p>\n\n\n\n<p>Seawater Pump Power Input Cable (<span translate=\"no\">Seakeeper<\/span> supplied)<\/p>\n\n\n\n<p><img decoding=\"async\" style=\"width: 40px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/Check-mark.png\" alt=\"\">    Connect the Seawater Pump Power Input Cable from <span translate=\"no\">Seakeeper<\/span> DC SW Pump In to 24 VDC power at customer supplied connection box or directly to circuit breaker<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"block-0245f132-91ab-40b8-b9f4-7018ebd3a54e\" style=\"font-size:25px\">Cooling Checklist<br>(Reference Installation Manual Section: Cooling Installation)<\/h2>\n\n\n\n<p><img decoding=\"async\" style=\"width: 40px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/Check-mark.png\" alt=\"\">    Verify coolant level in heat exchanger coolant reservoir.<\/p>\n\n\n\n<p><img decoding=\"async\" style=\"width: 40px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/Check-mark.png\" alt=\"\">    Connect seawater hoses \/ open sea cocks to heat exchanger and test seawater pump.<\/p>\n\n\n\n<p><img decoding=\"async\" style=\"width: 40px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/Check-mark.png\" alt=\"\">    Verify 13 GPM (49 LPM) minimum and 15 GPM (57 LPM) maximum seawater flow through heat exchanger under all operating conditions of the boat.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Please Complete Checklist and E-mail to support@seakeeper.com or emeasupport@seakeeper.com (outside of the Americas). Mechanical Checklist(Reference Installation Manual Section: Mechanical Installation) Seakeeper foundation installed in hull Foundation bolts torqued to specification Electrical Checklist(Reference Seakeeper Drawing No. 90710 \u2013 Seakeeper 40 Cable Block Diagram &amp; Installation Manual Section: Electrical Installation) Mount Components Multifunction Display (at helm) Remote [&hellip;]<\/p>\n","protected":false},"author":9,"featured_media":0,"parent":21007,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"manual":[371],"model":[],"document_type":[],"hidden":[],"class_list":["post-21011","page","type-page","status-publish","hentry","manual-seakeeper-40-installation-manual-90715-4-40-254-0200-to-current"],"acf":[],"_links":{"self":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/21011","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/comments?post=21011"}],"version-history":[{"count":3,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/21011\/revisions"}],"predecessor-version":[{"id":21151,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/21011\/revisions\/21151"}],"up":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/21007"}],"wp:attachment":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/media?parent=21011"}],"wp:term":[{"taxonomy":"manual","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/manual?post=21011"},{"taxonomy":"model","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/model?post=21011"},{"taxonomy":"document_type","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/document_type?post=21011"},{"taxonomy":"hidden","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/hidden?post=21011"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}