{"id":20967,"date":"2025-11-13T15:57:44","date_gmt":"2025-11-13T15:57:44","guid":{"rendered":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-40-installation-manual-90715-3-40-244-0121-to-current-copy\/mechanical-installation\/bolt-in-installation\/transfer-of-holes-to-boat-structure\/"},"modified":"2025-11-13T15:57:44","modified_gmt":"2025-11-13T15:57:44","slug":"transfer-of-holes-to-boat-structure","status":"publish","type":"page","link":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-40-installation-manual-90715-4-40-254-0200-to-current\/mechanical-installation\/bolt-in-installation\/transfer-of-holes-to-boat-structure\/","title":{"rendered":"2.4.2  Transfer of Holes to Boat Structure"},"content":{"rendered":"\n<ol class=\"wp-block-list\">\n<li>Lower assembled fixture onto hull structure.<\/li>\n\n\n\n<li><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-red-color\">The four areas where the isolation mounts will rest should be coplanar to within 0.13 in. (3 mm). See figure below.<\/mark> Do not use the fixture to check co-planarity as it is not stiff enough.<\/li>\n\n\n\n<li>Align fixture in desired location and transfer holes from fixture plate to the hull structure. A transfer punch is recommended for this step. Note that holes in fixture plate are 0.257 in. (6.5 mm) in diameter. <\/li>\n\n\n\n<li>Remove fixture and drill holes in hull structure at marked locations to mate with holes in <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> isolation mounts. A 0.689 in. (17.5 mm) diameter hole is recommended for the provided M16 fasteners.<\/li>\n<\/ol>\n\n\n\n<p><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-red-color\">NOTE: Certain foundation designs that employ threaded blind holes in thick plates may require the installer to obtain alternate fasteners. <\/mark><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"835\" height=\"642\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/SEAKEEPER-26-Bolt-In-Installation-Transfer-of-Holes-1.jpg\" alt=\"\" class=\"wp-image-4668\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SEAKEEPER-26-Bolt-In-Installation-Transfer-of-Holes-1.jpg 835w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SEAKEEPER-26-Bolt-In-Installation-Transfer-of-Holes-1-768x590.jpg 768w\" sizes=\"auto, (max-width: 835px) 100vw, 835px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"793\" height=\"776\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/SEAKEEPER-26-Bolt-In-Installation-Transfer-of-Holes-2.jpg\" alt=\"\" class=\"wp-image-4669\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SEAKEEPER-26-Bolt-In-Installation-Transfer-of-Holes-2.jpg 793w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SEAKEEPER-26-Bolt-In-Installation-Transfer-of-Holes-2-768x752.jpg 768w\" sizes=\"auto, (max-width: 793px) 100vw, 793px\" \/><\/figure>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>NOTE: Certain foundation designs that employ threaded blind holes in thick plates may require the installer to obtain alternate fasteners.<\/p>\n","protected":false},"author":9,"featured_media":0,"parent":20963,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"manual":[371],"model":[],"document_type":[],"hidden":[],"class_list":["post-20967","page","type-page","status-publish","hentry","manual-seakeeper-40-installation-manual-90715-4-40-254-0200-to-current"],"acf":[],"_links":{"self":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/20967","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/comments?post=20967"}],"version-history":[{"count":0,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/20967\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/20963"}],"wp:attachment":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/media?parent=20967"}],"wp:term":[{"taxonomy":"manual","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/manual?post=20967"},{"taxonomy":"model","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/model?post=20967"},{"taxonomy":"document_type","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/document_type?post=20967"},{"taxonomy":"hidden","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/hidden?post=20967"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}