{"id":20872,"date":"2025-11-13T13:45:54","date_gmt":"2025-11-13T13:45:54","guid":{"rendered":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-18-installation-manual-90672-2-s-n-18-234-2475-to-current-copy\/2-0-electrical-installation\/2-1-electrical-equipment-power-connections\/"},"modified":"2026-01-06T18:14:26","modified_gmt":"2026-01-06T18:14:26","slug":"2-1-electrical-equipment-power-connections","status":"publish","type":"page","link":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-18-installation-manual-90672-3-s-n-18-254-2135-to-current\/2-0-electrical-installation\/2-1-electrical-equipment-power-connections\/","title":{"rendered":"3.2  Electrical Equipment Power Connections"},"content":{"rendered":"\n<h3 class=\"wp-block-heading\">230 VAC Power Source Requirements<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>230 VAC (nominal), 1 Phase, 50\/60 Hz, 30 A<\/li>\n\n\n\n<li>For installations of more than one <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span>, a separate circuit breaker must be used for each <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> Motor Drive Box.<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\">Drive Box AC Power Input Connection Instructions<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>AC Power Input Cable: 3 x 10 AWG (3 x 6 mm<sup>2<\/sup> CSA), 10 ft9 (3 m) length, <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> supplied pre-installed.<br>\n<ol class=\"wp-block-list\">\n<li>Locate AC power input cable on the Drive Box at the outboard cable gland.<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"655\" height=\"764\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SK40-MDB.jpg\" alt=\"\" class=\"wp-image-15248\" style=\"width:261px;height:305px\"\/><figcaption class=\"wp-element-caption\"><strong><em>Figure 28 <\/em>&#8211; <\/strong><em>Drive Box AC Power Input &amp; Output Cable Glands<\/em><\/figcaption><\/figure>\n<\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"868\" height=\"285\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/Cable-2-Wire-Connections-at-AC-Power-Distribution-Panel.jpg\" alt=\"\" class=\"wp-image-4239\" style=\"width:481px;height:158px\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Cable-2-Wire-Connections-at-AC-Power-Distribution-Panel.jpg 868w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Cable-2-Wire-Connections-at-AC-Power-Distribution-Panel-768x252.jpg 768w\" sizes=\"auto, (max-width: 868px) 100vw, 868px\" \/><figcaption class=\"wp-element-caption\"><strong><em>Figure 29<\/em> &#8211; <\/strong><em>AC Power Input Cable wire <\/em><br><em>connections at AC Power Distribution Panel<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<p>2. Connect 230 VAC wires in AC Power Input Cable to a 30 A, double-pole Circuit Breaker at an AC <br> power distribution panel according to Figure 29 above.<\/p>\n\n\n\n<hr class=\"wp-block-separator is-style-wide\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" style=\"font-size:25px\">24 VDC Power Source Requirements<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>One 24 VDC, 10 A (Customer supplied) for <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> Control Power, <strong>AND<\/strong><\/li>\n\n\n\n<li>One 24 VDC, 10 A (20 A max)(Customer supplied) for DC Seawater Pump.<\/li>\n\n\n\n<li>A separate breaker should be used for each <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span>.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator is-style-wide\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" style=\"font-size:25px\">DC Power Connection Instructions<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\"><div class=\"wp-block-image\">\n<figure class=\"alignright size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"253\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/warning-icon.jpg\" alt=\"\" class=\"wp-image-1505\" style=\"width:159px;height:100px\"\/><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p><\/p>\n\n\n\n<p class=\"has-vivid-red-color has-text-color\"><strong>Reversing polarity on the DC power input to the <span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span> can result in damaging the electronics in the control system.<\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<ol class=\"wp-block-list\">\n<li>24 VDC, 10 A, 2 x 12 AWG (3 x 4.0 mm<sup>2<\/sup> CSA) customer supplied.<br>\n<ol class=\"wp-block-list\">\n<li>Install <span translate=\"no\"><span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span><\/span> provided DC Power Input Cable, P\/N 20248 (as shown in <strong>Drawing No. 90679<\/strong>).<br>\n<ol class=\"wp-block-list\">\n<li>Route 24 VDC Power Cable to DC Power Distribution Panel.<\/li>\n\n\n\n<li>Terminate positive (B+, Red ) conductor to +24 VDC. <\/li>\n\n\n\n<li>Terminate negative (B-, Black) conductor directly to battery negative terminal.<\/li>\n<\/ol>\n<\/li>\n\n\n\n<li>Before connecting cable to <span translate=\"no\"><span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span><\/span>, check for proper voltage and polarity with a DC multimeter using Figure 30 below.<\/li>\n\n\n\n<li>Connect 24 VDC Input Cable to 24 VDC input receptacle on <span translate=\"no\"><span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span><\/span>.<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"627\" height=\"447\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/DC-Power-Input-Connector-Contact-Assignments-Front.jpg\" alt=\"\" class=\"wp-image-4255\" style=\"width:290px;height:206px\"\/><figcaption class=\"wp-element-caption\"><em><strong>Figure 30 \u2013 <\/strong>DC Power Input Connector Contact Assignments (front)<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<hr class=\"wp-block-separator is-style-wide\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">DC Seawater Pump 24 VDC Power Input Connection Instructions<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\"><div class=\"wp-block-image\">\n<figure class=\"alignright size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"406\" height=\"358\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/CAUTION.png\" alt=\"\" class=\"wp-image-10247\" style=\"width:119px;height:105px\"\/><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p><\/p>\n\n\n\n<p class=\"has-vivid-red-color has-text-color\"><strong>Connecting the DC Seawater pump in any other manner than recommended by <span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span> may cause internal failure.<\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<ol style=\"list-style-type:1\" class=\"wp-block-list\">\n<li>Install Seawater Pump Input Cable (P\/N 20454) to <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> 18 \u201cSW Pump DC In\u201d (as shown in <strong>Drawing No. 90679<\/strong>) with overcurrent protection corresponding to seawater pump selected.<\/li>\n\n\n\n<li>Connect the 14 AWG positive conductor (Red) through dedicated overcurrent protection device (customer supplied), maximum of 20 A, to dedicated battery isolation switch.<\/li>\n\n\n\n<li>Connect the 14 AWG negative conductor (Black) directly to battery negative terminal or DC main negative bus bar.<\/li>\n\n\n\n<li>Before connecting Seawater Pump Input Cable to <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span>, check for proper voltage and polarity with a DC multimeter using Figure 31 below.<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"213\" height=\"148\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Figure-5.png\" alt=\"\" class=\"wp-image-9376\" style=\"width:377px;height:262px\"\/><figcaption class=\"wp-element-caption\"><em><strong>Figure 31<\/strong> &#8211; 24 VDC Seawater Pump Power Input<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<ol start=\"5\" class=\"wp-block-list\">\n<li>Connect Seawater Pump Input Cable to Seawater Pump 24 VDC In connector on the <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span>, DEUTSCH DT04-2P connector.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator is-style-wide\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">DC Seawater Pump 24 VDC Power Output Connection Instructions<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Connect Seawater Pump Output Cable (P\/N 20455) to the <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> 18 wire harness connector labelled <em>Seawater Pump Out<\/em>.<br>\n<ol class=\"wp-block-list\">\n<li>Seawater Pump Output Cable is a 2 x 14 AWG cable, 16 ft (5 m) length with a female Deutsch plug.<\/li>\n\n\n\n<li>Install Y-Branch SW Pump Output &amp; Valve cable (P\/N 20658) to end of &#8220;SW Pump 24VDC Out&#8221; cable as shown in top image of Figure 3324.<\/li>\n<\/ol>\n<\/li>\n\n\n\n<li>Pumps rated at 24 VDC, 10 A maximum, customer-supplied, must be configured with a Deutsch DT series, 2-pin receptacle to mate with the connector shown in Figure 32.<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1881\" height=\"1113\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/DTP06-2S.png\" alt=\"\" class=\"wp-image-18295\" style=\"aspect-ratio:1.6900682725750353;width:434px;height:auto\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/DTP06-2S.png 1881w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/DTP06-2S-768x454.png 768w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/DTP06-2S-1536x909.png 1536w\" sizes=\"auto, (max-width: 1881px) 100vw, 1881px\" \/><figcaption class=\"wp-element-caption\"><strong><em>Figure 32 <\/em><\/strong><em>&#8211; Seawater Pump Deutsch Connector<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<ol start=\"3\" style=\"list-style-type:1\" class=\"wp-block-list\">\n<li>The Seawater Pump Output Cable must be routed and installed in the vessel to the Y-Branch SW Pump Output &amp; Valve Cable (P\/N 20658) (socket end).<\/li>\n\n\n\n<li>Connect Y-branch cable plug end (socket end) to the customer-supplied receptacle end of the DC seawater pump cable. The recommended wiring is shown in Figure 33.<\/li>\n\n\n\n<li>Attach DTM-2S (socket end) into the male Deutsch DTM-2P connector of the 1 A inline fuse cable (P\/N 20794). Connect the female connector of the inline fuse cable into the connector of the electric ball valve.<\/li>\n\n\n\n<li>Contact <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> if desired to install customer-supplied relay on Seawater Pump Output Cable to power seawater pump and valve.<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1152\" height=\"352\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Seawater-Cable-w-Valve-24V-1.png\" alt=\"\" class=\"wp-image-21184\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Seawater-Cable-w-Valve-24V-1.png 1152w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Seawater-Cable-w-Valve-24V-1-768x235.png 768w\" sizes=\"auto, (max-width: 1152px) 100vw, 1152px\" \/><figcaption class=\"wp-element-caption\"><strong><em>Figure 33<\/em><\/strong><em> &#8211; Seawater Pump Output Cable &#8211; Seawater Pump<\/em><\/figcaption><\/figure>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>230 VAC Power Source Requirements Drive Box AC Power Input Connection Instructions 2. Connect 230 VAC wires in AC Power Input Cable to a 30 A, double-pole Circuit Breaker at an AC power distribution panel according to Figure 29 above. 24 VDC Power Source Requirements DC Power Connection Instructions Reversing polarity on the DC power [&hellip;]<\/p>\n","protected":false},"author":9,"featured_media":0,"parent":20868,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"manual":[369],"model":[],"document_type":[],"hidden":[],"class_list":["post-20872","page","type-page","status-publish","hentry","manual-seakeeper-18-installation-manual-90672-3-s-n-18-254-2135-to-current"],"acf":[],"_links":{"self":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/20872","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/comments?post=20872"}],"version-history":[{"count":4,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/20872\/revisions"}],"predecessor-version":[{"id":21223,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/20872\/revisions\/21223"}],"up":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/20868"}],"wp:attachment":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/media?parent=20872"}],"wp:term":[{"taxonomy":"manual","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/manual?post=20872"},{"taxonomy":"model","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/model?post=20872"},{"taxonomy":"document_type","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/document_type?post=20872"},{"taxonomy":"hidden","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/hidden?post=20872"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}