{"id":20870,"date":"2025-11-13T13:45:54","date_gmt":"2025-11-13T13:45:54","guid":{"rendered":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-18-installation-manual-90672-2-s-n-18-234-2475-to-current-copy\/2-0-electrical-installation\/introduction\/"},"modified":"2025-11-21T16:59:52","modified_gmt":"2025-11-21T16:59:52","slug":"introduction","status":"publish","type":"page","link":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-18-installation-manual-90672-3-s-n-18-254-2135-to-current\/2-0-electrical-installation\/introduction\/","title":{"rendered":"3.1  Electrical Introduction"},"content":{"rendered":"\n<p>This section for electrical installation explains how to mount the electrical equipment and how to connect the electrical cables. Additional references are provided in associated sections.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Reference Documents and Drawings<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.seakeeper.com\/technical-library\/?type=&amp;product=&amp;search=90667\" target=\"_blank\" rel=\"noreferrer noopener\">90667 &#8211; <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> 18 Hardware Scope of Supply<\/a><\/li>\n\n\n\n<li><a rel=\"noreferrer noopener\" href=\"https:\/\/www.seakeeper.com\/technical-library\/?type=&amp;product=&amp;search=90679\" target=\"_blank\">90679 &#8211; <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> 18 Cable Block Diagram<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.seakeeper.com\/technical-library\/?type=&amp;product=&amp;search=90558\" target=\"_blank\" rel=\"noreferrer noopener\">90558 &#8211; ConnectBox Helm Mounting Kit<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.seakeeper.com\/technical-library\/?type=&amp;product=&amp;search=90896\" target=\"_blank\" rel=\"noreferrer noopener\">TB-90896 &#8211; ConnectBox Installation Guide<\/a><\/li>\n\n\n\n<li>MFD Compatibility Bulletins<br>\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.seakeeper.com\/technical-library\/?type=&amp;product=&amp;search=90478\" target=\"_blank\" rel=\"noreferrer noopener\">TB-90478 &#8211; Garmin and <span translate=\"no\"><span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span><\/span> Compatibility<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.seakeeper.com\/technical-library\/?type=&amp;product=&amp;search=90479\" target=\"_blank\" rel=\"noreferrer noopener\">TB-90479 &#8211; Raymarine and <span translate=\"no\"><span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span><\/span> Compatibility<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.seakeeper.com\/technical-library\/?type=&amp;product=&amp;search=90480\" target=\"_blank\" rel=\"noreferrer noopener\">TB-90480 &#8211; NAVICO and <span translate=\"no\"><span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span><\/span> Compatibility<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.seakeeper.com\/technical-library\/?type=&amp;product=&amp;search=90598\" target=\"_blank\" rel=\"noreferrer noopener\">TB-90598 &#8211; Furuno and <span translate=\"no\"><span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span><\/span> Compatibility<\/a><\/li>\n<\/ul>\n<\/li>\n\n\n\n<li>Optional 5&#8243; Touch Display References<br>\n<ul class=\"wp-block-list\">\n<li><a rel=\"noreferrer noopener\" href=\"https:\/\/www.seakeeper.com\/technical-library\/?type=&amp;product=&amp;search=90600\" target=\"_blank\">90467 &#8211; <span translate=\"no\"><span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span><\/span> 5&#8243; Display Kit<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.seakeeper.com\/technical-library\/?type=&amp;product=&amp;search=90438\" target=\"_blank\" rel=\"noreferrer noopener\">90438 \u2013 5\u2033 Operator Display Envelope and Mounting Details<\/a><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1280\" height=\"905\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Seakeeper-18-Isometric.jpg\" alt=\"\" class=\"wp-image-20926\" style=\"object-fit:cover;width:536px;height:400px\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Seakeeper-18-Isometric.jpg 1280w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Seakeeper-18-Isometric-768x543.jpg 768w\" sizes=\"auto, (max-width: 1280px) 100vw, 1280px\" \/><figcaption class=\"wp-element-caption\"><em>SEAKEEPER 18, Front<\/em><em> Isometric View<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"236\" height=\"178\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Cable-8.jpg\" alt=\"\" class=\"wp-image-10416\"\/><figcaption class=\"wp-element-caption\">20248, 24 VDC Power Input Cable,<br>16 ft (5 m)<\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"656\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Cable-11-NMEA-6m.jpg\" alt=\"\" class=\"wp-image-1470\" style=\"width:243px;height:266px\"\/><figcaption class=\"wp-element-caption\">30332, NMEA 2000 Drop Cable,<br>19 ft (6 m)<\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"600\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/able-10-D-Code-10-m.jpg\" alt=\"\" class=\"wp-image-1471\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/able-10-D-Code-10-m.jpg 600w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/able-10-D-Code-10-m-150x150.jpg 150w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><figcaption class=\"wp-element-caption\">30355, M12 D-Code Female-Male,<br>82 ft (25 m)<\/figcaption><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"802\" height=\"560\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/SEAKEEPER-18-Cable-5-DC-Seawater-Pump-Output-Power-Cable-Male-Female.jpg\" alt=\"\" class=\"wp-image-4509\" style=\"width:261px;height:182px\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SEAKEEPER-18-Cable-5-DC-Seawater-Pump-Output-Power-Cable-Male-Female.jpg 802w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SEAKEEPER-18-Cable-5-DC-Seawater-Pump-Output-Power-Cable-Male-Female-768x536.jpg 768w\" sizes=\"auto, (max-width: 802px) 100vw, 802px\" \/><figcaption class=\"wp-element-caption\">20455, DC Seawater Pump, Output Power, <br>Male-Female Cable, 16 ft (5 m)<\/figcaption><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1280\" height=\"905\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/20658-Y-Branch-Cable.png\" alt=\"\" class=\"wp-image-20613\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/20658-Y-Branch-Cable.png 1280w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/20658-Y-Branch-Cable-768x543.png 768w\" sizes=\"auto, (max-width: 1280px) 100vw, 1280px\" \/><figcaption class=\"wp-element-caption\">20658, Y-Branch Seawater Pump Output &amp; Valve Cable<\/figcaption><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"528\" height=\"441\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/SEAKEEPER-18-Cable-8-DC-Seawater-Pump-Input-Power-Cable-Female-Only.jpg\" alt=\"\" class=\"wp-image-4510\" style=\"width:260px;height:217px\"\/><figcaption class=\"wp-element-caption\">20454, DC Seawater Pump, Input Power,<br>Female Only Cable, 16 ft (5 m)<\/figcaption><\/figure>\n<\/div><\/div>\n<\/div>\n\n\n\n<p class=\"has-text-align-center\"><strong><em>Figure <\/em>27 <em>&#8211;<\/em> <\/strong><em>Electrical equipment for <span translate=\"no\">Seakeeper<\/span> 1<\/em>8<\/p>\n","protected":false},"excerpt":{"rendered":"<p>This section for electrical installation explains how to mount the electrical equipment and how to connect the electrical cables. Additional references are provided in associated sections. Reference Documents and Drawings Figure 27 &#8211; Electrical equipment for Seakeeper 18<\/p>\n","protected":false},"author":9,"featured_media":0,"parent":20868,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"manual":[369],"model":[],"document_type":[],"hidden":[],"class_list":["post-20870","page","type-page","status-publish","hentry","manual-seakeeper-18-installation-manual-90672-3-s-n-18-254-2135-to-current"],"acf":[],"_links":{"self":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/20870","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/comments?post=20870"}],"version-history":[{"count":2,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/20870\/revisions"}],"predecessor-version":[{"id":21123,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/20870\/revisions\/21123"}],"up":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/20868"}],"wp:attachment":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/media?parent=20870"}],"wp:term":[{"taxonomy":"manual","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/manual?post=20870"},{"taxonomy":"model","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/model?post=20870"},{"taxonomy":"document_type","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/document_type?post=20870"},{"taxonomy":"hidden","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/hidden?post=20870"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}