{"id":20780,"date":"2025-11-12T19:20:32","date_gmt":"2025-11-12T19:20:32","guid":{"rendered":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-14-installation-manual-90873-1-copy\/electrical-installation\/electrical-equipment-power-connections-2\/"},"modified":"2026-01-06T17:55:00","modified_gmt":"2026-01-06T17:55:00","slug":"electrical-equipment-power-connections-2","status":"publish","type":"page","link":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-14-installation-manual-90873-2\/electrical-installation\/electrical-equipment-power-connections-2\/","title":{"rendered":"3.2  Electrical Equipment Power Connections"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" style=\"font-size:25px\">230 VAC Power Source Requirements<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>230 VAC (nominal), 1 Phase, 50\/60 Hz, 30 A<\/li>\n\n\n\n<li>For installations of more than one <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span>, a separate circuit breaker should be used for each <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> Motor Drive Box.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator is-style-wide\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" style=\"font-size:25px\">Drive Box AC Power Input Connection Instructions<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>230 VAC Input Cable: 3 x 10 AWG (3 x 6 mm<sup>2<\/sup> CSA), 10 ft. (3 m) length, <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> supplied pre-installed.<br>\n<ol class=\"wp-block-list\">\n<li>Locate 230 VAC Input Cable for AC power input to the Drive Box at the outboard of the Motor Drive Box cable glands.<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"2794\" height=\"1911\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/MDB.png\" alt=\"\" class=\"wp-image-18292\" style=\"width:458px;height:auto\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/MDB.png 2794w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/MDB-768x525.png 768w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/MDB-1536x1051.png 1536w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/MDB-2048x1401.png 2048w\" sizes=\"auto, (max-width: 2794px) 100vw, 2794px\" \/><figcaption class=\"wp-element-caption\"><strong><em>Figure 12<\/em><\/strong><em> &#8211; Drive Box AC Power Input and Motor Output Glands<\/em><\/figcaption><\/figure>\n<\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"346\" height=\"114\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Picture5.jpg\" alt=\"\" class=\"wp-image-10424\" style=\"width:438px;height:144px\"\/><figcaption class=\"wp-element-caption\"><strong><em>Figure 13<\/em><\/strong><em> &#8211; 230 VAC Input Cable Wire <\/em><br><em>Connections at AC Power Distribution Panel<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<ol start=\"2\" class=\"wp-block-list\">\n<li>Connect 230 VAC Input Cable wires to a <strong>30 A<\/strong>, double-pole Circuit Breaker at an AC power distribution panel according to Figure 13 above.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator is-style-wide\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" style=\"font-size:25px\">24 VDC Power Source Requirements<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>One 24 VDC, <strong>10 A<\/strong> (Customer supplied) for <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> Control Power, <strong>AND<\/strong><\/li>\n\n\n\n<li>One 24 VDC, <strong>10 A<sup>*<\/sup><\/strong> (Customer supplied) for DC Seawater Pump.<\/li>\n\n\n\n<li>A separate breaker should be used for each <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span>.<\/li>\n<\/ol>\n\n\n\n<p><strong>*<\/strong> Alternate seawater pump configuration for customer-supplied DC-powered seawater pump, 24 VDC at <strong>20 A<\/strong> maximum.<\/p>\n\n\n\n<hr class=\"wp-block-separator is-style-wide\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" style=\"font-size:25px\">DC Power Connection Instructions<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\"><div class=\"wp-block-image\">\n<figure class=\"alignright size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"253\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/warning-icon.jpg\" alt=\"\" class=\"wp-image-1505\" style=\"width:159px;height:100px\"\/><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p><\/p>\n\n\n\n<p class=\"has-vivid-red-color has-text-color\"><strong>Reversing polarity on the DC power input to the <span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span> can result in damaging the electronics in the control system.<\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<ol class=\"wp-block-list\">\n<li>24 VDC, 10 A, 2 x 12 AWG (3 x 4.0 mm<sup>2<\/sup> CSA) customer supplied.<br>\n<ol class=\"wp-block-list\">\n<li>Install <span translate=\"no\"><span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span><\/span> provided DC Power Input Cable, P\/N 20248 (as shown in <strong>Drawing No. 90859<\/strong>).<br>\n<ol class=\"wp-block-list\">\n<li>Route 24 VDC Power Cable to DC Power Distribution Panel.<\/li>\n\n\n\n<li>Terminate positive (B+, Red ) conductor to +24 VDC. <\/li>\n\n\n\n<li>Terminate negative (B-, Black) conductor directly to battery negative terminal.<\/li>\n<\/ol>\n<\/li>\n\n\n\n<li>Before connecting cable to <span translate=\"no\"><span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span><\/span>, check for proper voltage and polarity with a DC multimeter using Figure 14 below.<\/li>\n\n\n\n<li>Connect 24 VDC Input Cable to 24 VDC input receptacle on <span translate=\"no\"><span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span><\/span>.<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"627\" height=\"447\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/DC-Power-Input-Connector-Contact-Assignments-Front.jpg\" alt=\"\" class=\"wp-image-4255\" style=\"width:290px;height:206px\"\/><figcaption class=\"wp-element-caption\"><em><strong>Figure 14 \u2013 <\/strong>DC Power Input Connector Contact Assignments (front)<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<hr class=\"wp-block-separator is-style-wide\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">DC Seawater Pump 24 VDC Power Input Connection Instructions<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\"><div class=\"wp-block-image\">\n<figure class=\"alignright size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"406\" height=\"358\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/CAUTION.png\" alt=\"\" class=\"wp-image-10247\" style=\"width:119px;height:105px\"\/><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p><\/p>\n\n\n\n<p class=\"has-vivid-red-color has-text-color\"><strong>Connecting the DC Seawater pump in any other manner than recommended by <span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span> may cause internal failure.<\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<ol style=\"list-style-type:1\" class=\"wp-block-list\">\n<li>Install Seawater Pump Input Cable (P\/N 20454) to <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> 14 \u201cSW Pump VDC In\u201d (as shown in <strong>Drawing No. 90859<\/strong>) with overcurrent protection corresponding to seawater pump selected.<\/li>\n\n\n\n<li>Connect the 14 AWG positive conductor (Red) through dedicated overcurrent protection device (customer supplied), <strong>10 A<\/strong> (20 A maximum), to dedicated battery isolation switch.<\/li>\n\n\n\n<li>Connect the 14 AWG negative conductor (Black) directly to battery negative terminal or DC main negative bus bar.<\/li>\n\n\n\n<li>Before connecting Seawater Pump Input Cable to <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span>, check for proper voltage and polarity with a DC multimeter using Figure 15 below.<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"213\" height=\"148\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Figure-5.png\" alt=\"\" class=\"wp-image-9376\" style=\"width:377px;height:262px\"\/><figcaption class=\"wp-element-caption\"><em><strong>Figure 15<\/strong> &#8211; 24 VDC Seawater Pump Power Input<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<ol start=\"5\" class=\"wp-block-list\">\n<li>Connect Seawater Pump Input Cable to Seawater Pump 24 VDC In connector on the <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span>, DEUTSCH DT04-2P connector.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator is-style-wide\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">DC Seawater Pump 24 VDC Power Output Connection Instructions<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Connect Seawater Pump Output Cable to the <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> 14 \u201cSW Pump VDC Out\u201d for DC power to the seawater pump.<br>\n<ol class=\"wp-block-list\">\n<li>Seawater Pump Output Cable is a 2 x 14 AWG cable, 16 ft (5m) length with a size 14 female Deutsch plug.<\/li>\n\n\n\n<li>Install Y-Branch SW Pump Output &amp; Valve cable (P\/N 20658) to end of &#8220;SW Pump 24VDC Out&#8221; cable as shown in top image of Figure 17<\/li>\n<\/ol>\n<\/li>\n\n\n\n<li>Pumps rated at 24 VDC, 10 A maximum, customer-supplied, must be configured with a Deutsch DT series, 2-pin receptacle to mate with the connector shown in Figure 16.<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1881\" height=\"1113\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/DTP06-2S.png\" alt=\"\" class=\"wp-image-18295\" style=\"width:344px;height:auto\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/DTP06-2S.png 1881w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/DTP06-2S-768x454.png 768w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/DTP06-2S-1536x909.png 1536w\" sizes=\"auto, (max-width: 1881px) 100vw, 1881px\" \/><figcaption class=\"wp-element-caption\"><strong><em>Figure 16 <\/em><\/strong><em>&#8211; Seawater Pump Deutsch Connector<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<ol start=\"3\" style=\"list-style-type:1\" class=\"wp-block-list\">\n<li>The DC SW Pump Power Output Cable must be routed and installed in the vessel from the <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> 14 \u201cSW Pump 24VDC Out\u201d Deutsch connector (pins end) to the Y-Branch SW Pump Output &amp; Valve Cable (P\/N 20658) (socket end).<\/li>\n\n\n\n<li>Connect Y-branch cable plug end (socket end) to the customer-supplied receptacle end (pins end). The recommended wiring is shown in Figure 17.<\/li>\n\n\n\n<li>Connect Y-branch cable DTM-2S connector to DTM-2P connector of inline 1 A fuse cable (P\/N 20794) and the electric valve.<\/li>\n\n\n\n<li>Contact <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> if desired to install customer-supplied relay on DC SW Pump Power Output Cable to power Seawater Pump and valve.<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1152\" height=\"352\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Seawater-Cable-w-Valve-24V-1.png\" alt=\"\" class=\"wp-image-21184\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Seawater-Cable-w-Valve-24V-1.png 1152w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Seawater-Cable-w-Valve-24V-1-768x235.png 768w\" sizes=\"auto, (max-width: 1152px) 100vw, 1152px\" \/><figcaption class=\"wp-element-caption\"><strong><em>Figure 17<\/em><\/strong><em> &#8211; 24 VDC SW Pump Schematic<\/em><\/figcaption><\/figure>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>230 VAC Power Source Requirements Drive Box AC Power Input Connection Instructions 24 VDC Power Source Requirements * Alternate seawater pump configuration for customer-supplied DC-powered seawater pump, 24 VDC at 20 A maximum. DC Power Connection Instructions Reversing polarity on the DC power input to the Seakeeper can result in damaging the electronics in the [&hellip;]<\/p>\n","protected":false},"author":9,"featured_media":0,"parent":20776,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"manual":[367],"model":[],"document_type":[],"hidden":[],"class_list":["post-20780","page","type-page","status-publish","hentry","manual-seakeeper-14-installation-manual-90873-2"],"acf":[],"_links":{"self":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/20780","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/comments?post=20780"}],"version-history":[{"count":7,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/20780\/revisions"}],"predecessor-version":[{"id":21212,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/20780\/revisions\/21212"}],"up":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/20776"}],"wp:attachment":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/media?parent=20780"}],"wp:term":[{"taxonomy":"manual","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/manual?post=20780"},{"taxonomy":"model","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/model?post=20780"},{"taxonomy":"document_type","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/document_type?post=20780"},{"taxonomy":"hidden","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/hidden?post=20780"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}