{"id":20690,"date":"2025-11-12T17:56:37","date_gmt":"2025-11-12T17:56:37","guid":{"rendered":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-10-installation-manual-90841-1-copy\/installation-checklist-and-supplies\/required-supplies-needed-for-seakeeper-installation\/"},"modified":"2025-11-20T17:15:14","modified_gmt":"2025-11-20T17:15:14","slug":"required-supplies-needed-for-seakeeper-installation","status":"publish","type":"page","link":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-10-installation-manual-90841-2\/installation-checklist-and-supplies\/required-supplies-needed-for-seakeeper-installation\/","title":{"rendered":"5.2  Required Supplies and Tools for Installation"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" id=\"block-cc9a261a-6fb8-4cea-b93c-3c7300df6803\" style=\"font-size:25px\">5.2.1 Required Supplies Needed for <span translate=\"no\">Seakeeper<\/span> Installation<br>(Not Supplied with the <span translate=\"no\">Seakeeper<\/span>)<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Item<\/th><th>Description<\/th><th>Qty<\/th><th>Installation Manual Reference Section<\/th><th>Other Reference<\/th><th>System<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td>Adhesive and cleaning supplies for bonding to hull<\/td><td>AR<\/td><td><a href=\"https:\/\/manuals.seakeeper.com\/seakeeper-9-installation-manual\/mechanical-installation\/introduction\" data-type=\"URL\" data-id=\"https:\/\/manuals.seakeeper.com\/seakeeper-9-installation-manual\/mechanical-installation\/introduction\" target=\"_blank\" rel=\"noreferrer noopener\">Mechanical Installation<\/a> <\/td><td><\/td><td>Mechanical<\/td><\/tr><tr><td>2<\/td><td>Soundproofing Considerations<\/td><td>AR<\/td><td><a rel=\"noreferrer noopener\" href=\"https:\/\/manuals.seakeeper.com\/seakeeper-9-installation-manual\/mechanical-installation\/selection-of-installation-location\/\" data-type=\"URL\" data-id=\"https:\/\/manuals.seakeeper.com\/seakeeper-9-installation-manual\/mechanical-installation\/selection-of-installation-location\/\" target=\"_blank\">Selection of Installation Location<\/a><\/td><td><\/td><td>Mechanical<\/td><\/tr><tr><td>3<\/td><td>Spreader bar for lifting <span translate=\"no\">Seakeeper<\/span><\/td><td>1<\/td><td><a rel=\"noreferrer noopener\" href=\"https:\/\/manuals.seakeeper.com\/seakeeper-9-installation-manual\/mechanical-installation\/transport-and-unpacking\/\" data-type=\"URL\" data-id=\"https:\/\/manuals.seakeeper.com\/seakeeper-9-installation-manual\/mechanical-installation\/transport-and-unpacking\/\" target=\"_blank\">Transport and Unpacking<\/a><\/td><td>P\/N 11015<\/td><td>Mechanical<\/td><\/tr><tr><td>4<\/td><td>Threaded insert: M14-2 x 1.5DIA (21 mm)<\/td><td>16<\/td><td><a rel=\"noreferrer noopener\" href=\"https:\/\/manuals.seakeeper.com\/seakeeper-9-installation-manual\/mechanical-installation\/introduction\" data-type=\"URL\" data-id=\"https:\/\/manuals.seakeeper.com\/seakeeper-9-installation-manual\/mechanical-installation\/introduction\" target=\"_blank\">Mechanical Installation<\/a> <\/td><td>Dwg 90255<\/td><td>Mechanical<\/td><\/tr><tr><td>5<\/td><td>Marine Sealant<\/td><td>AR<\/td><td><a rel=\"noreferrer noopener\" href=\"https:\/\/manuals.seakeeper.com\/seakeeper-9-installation-manual\/mechanical-installation\/introduction\" data-type=\"URL\" data-id=\"https:\/\/manuals.seakeeper.com\/seakeeper-9-installation-manual\/mechanical-installation\/introduction\" target=\"_blank\">Mechanical Installation<\/a> <\/td><td>Dwg 90255<\/td><td>Mechanical<\/td><\/tr><tr><td>6<\/td><td>Nickel-Based Anti-Seize (<mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\">SAF-T-EZE <\/mark>SBT-4N, or similar)<\/td><td>AR<\/td><td><a rel=\"noreferrer noopener\" href=\"https:\/\/manuals.seakeeper.com\/seakeeper-9-installation-manual\/mechanical-installation\/introduction\" data-type=\"URL\" data-id=\"https:\/\/manuals.seakeeper.com\/seakeeper-9-installation-manual\/mechanical-installation\/introduction\" target=\"_blank\">Mechanical Installation<\/a><\/td><td>Dwg 90255<\/td><td>Mechanical<\/td><\/tr><tr><td>7<\/td><td>Circuit Breaker, AC, 2-Pole, 30 A<\/td><td>1<\/td><td><a href=\"https:\/\/manuals.seakeeper.com\/seakeeper-9-installation-manual\/electrical-installation\/electrical-equipment-power-connections-2\/\" data-type=\"URL\" data-id=\"https:\/\/manuals.seakeeper.com\/seakeeper-9-installation-manual\/electrical-installation\/electrical-equipment-power-connections-2\/\" target=\"_blank\" rel=\"noreferrer noopener\">Electrical Equipment Power Connections<\/a><\/td><td>Dwg 90257<\/td><td>Electrical<\/td><\/tr><tr><td>8<\/td><td>Circuit Breaker, DC, 1-Pole, 10 A, Gyro Controller<\/td><td>1<\/td><td><a rel=\"noreferrer noopener\" href=\"https:\/\/manuals.seakeeper.com\/seakeeper-9-installation-manual\/electrical-installation\/electrical-equipment-power-connections-2\/\" data-type=\"URL\" data-id=\"https:\/\/manuals.seakeeper.com\/seakeeper-9-installation-manual\/electrical-installation\/electrical-equipment-power-connections-2\/\" target=\"_blank\">Electrical Equipment Power Connections<\/a> <\/td><td>Dwg 90257<\/td><td>Electrical<\/td><\/tr><tr><td>9<\/td><td>Circuit Breaker, DC, 1-Pole, 10 A max, Seawater Pump<\/td><td>1<\/td><td><a rel=\"noreferrer noopener\" href=\"https:\/\/manuals.seakeeper.com\/seakeeper-9-installation-manual\/electrical-installation\/electrical-equipment-power-connections-2\/\" target=\"_blank\">Electrical Equipment Power Connections<\/a><\/td><td>Dwg 90257<\/td><td>Electrical<\/td><\/tr><tr><td>10<\/td><td>M6 terminal lug for grounding <span translate=\"no\">Seakeeper<\/span> at rear brace<\/td><td>1<\/td><td><a href=\"https:\/\/manuals.seakeeper.com\/seakeeper-9-installation-manual\/electrical-installation\/electrical-equipment-ground-connections\/\" data-type=\"URL\" data-id=\"https:\/\/manuals.seakeeper.com\/seakeeper-9-installation-manual\/electrical-installation\/electrical-equipment-ground-connections\/\" target=\"_blank\" rel=\"noreferrer noopener\">Electrical Equipment Ground Connections<\/a><\/td><td>Dwg 90257<\/td><td>Electrical<\/td><\/tr><tr><td>11<\/td><td>Marine Cable, Green, 10 AWG, Cable 6 ground connection (used with item 11)<\/td><td>AR<\/td><td><a rel=\"noreferrer noopener\" href=\"https:\/\/manuals.seakeeper.com\/seakeeper-9-installation-manual\/electrical-installation\/electrical-equipment-ground-connections\/\" data-type=\"URL\" data-id=\"https:\/\/manuals.seakeeper.com\/seakeeper-9-installation-manual\/electrical-installation\/electrical-equipment-ground-connections\/\" target=\"_blank\">Electrical Equipment Ground Connections<\/a> <\/td><td>Dwg 90257<\/td><td>Electrical<\/td><\/tr><tr><td>12<\/td><td>Seawater pump, 24 VDC<\/td><td>1<\/td><td><a rel=\"noreferrer noopener\" href=\"https:\/\/manuals.seakeeper.com\/seakeeper-9-installation-manual\/electrical-installation\/electrical-equipment-power-connections-2\/\" data-type=\"URL\" data-id=\"https:\/\/manuals.seakeeper.com\/seakeeper-9-installation-manual\/electrical-installation\/electrical-equipment-power-connections-2\/\" target=\"_blank\">Electrical Equipment Power Connections<\/a> <\/td><td>Dwg 90257<\/td><td>Electrical<\/td><\/tr><tr><td>13<\/td><td>Relay for seawater pump control (Not required if using 24 VDC pump)<\/td><td>1<\/td><td><a rel=\"noreferrer noopener\" href=\"https:\/\/manuals.seakeeper.com\/seakeeper-9-installation-manual\/electrical-installation\/electrical-equipment-power-connections-2\/\" data-type=\"URL\" data-id=\"https:\/\/manuals.seakeeper.com\/seakeeper-9-installation-manual\/electrical-installation\/electrical-equipment-power-connections-2\/\" target=\"_blank\">Electrical Equipment Power Connections<\/a> <\/td><td><\/td><td>Electrical<\/td><\/tr><tr><td>14<\/td><td>Through-hull fittings (1 pick-up, 1 overboard discharge)<\/td><td>2<\/td><td><a href=\"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-9-installation-manual\/cooling-installation\/introduction\/\" data-type=\"URL\" data-id=\"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-9-installation-manual\/cooling-installation\/introduction\/\">Cooling Installation<\/a><\/td><td>Dwg 90251<\/td><td>Cooling<\/td><\/tr><tr><td>15<\/td><td>Seacock Valve<\/td><td>1<\/td><td><a href=\"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-9-installation-manual\/cooling-installation\/introduction\/\">Cooling Installation<\/a><\/td><td>Dwg 90251<\/td><td>Cooling<\/td><\/tr><tr><td>16<\/td><td>Seawater Strainer (Included with&nbsp;<span translate=\"no\">Seakeeper<\/span>&nbsp;Seawater Pump P\/N 30322)<\/td><td>1<\/td><td><a href=\"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-9-installation-manual\/cooling-installation\/introduction\/\">Cooling Installation<\/a><\/td><td>Dwg 90251<\/td><td>Cooling<\/td><\/tr><tr><td>17<\/td><td>3\/4 in. ID Seawater Hose<\/td><td>AR<\/td><td><a href=\"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-9-installation-manual\/cooling-installation\/connecting-seawater-to-heat-exchanger\/\" data-type=\"URL\" data-id=\"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-9-installation-manual\/cooling-installation\/connecting-seawater-to-heat-exchanger\/\">Connecting Seawater<\/a><\/td><td>Dwg 90251<\/td><td>Cooling<\/td><\/tr><tr><td>18<\/td><td>Hose clamps for seawater plumbing to \u00be in. (19 mm) hose barb (2 per hose barb)<\/td><td>AR<\/td><td><a href=\"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-9-installation-manual\/cooling-installation\/connecting-seawater-to-heat-exchanger\/\" data-type=\"URL\" data-id=\"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-9-installation-manual\/cooling-installation\/connecting-seawater-to-heat-exchanger\/\">Connecting Seawater<\/a><\/td><td>Dwg 90251<\/td><td>Cooling<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\"><strong><br>AR = As Required<br>Dwg = Drawing<\/strong><\/figcaption><\/figure>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" style=\"font-size:25px\">5.2.2 List of Common Tools That May Be Required for Installation<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Item<\/th><th>Description<\/th><th>Use<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td>Wire cutter<\/td><td>DC Power, AC Power cables<\/td><\/tr><tr><td>2<\/td><td>Wire stripper<\/td><td>DC Power, AC Power cables<\/td><\/tr><tr><td>3<\/td><td>13 mm Socket <\/td><td>Side Panels<\/td><\/tr><tr><td>4<\/td><td>24 mm Socket<\/td><td>Foundation bolts<\/td><\/tr><tr><td>5<\/td><td>3 mm hex key<\/td><td>Gimbal sensor mount plate<\/td><\/tr><tr><td>6<\/td><td>2.5 mm hex key<\/td><td>Gimbal angle sensor<\/td><\/tr><tr><td>7<\/td><td>\u00bc in. Nut Driver<\/td><td>Hose clamps<\/td><\/tr><tr><td>8<\/td><td>Terminal or quick disconnect crimper<\/td><td>Power cables<\/td><\/tr><tr><td>9<\/td><td>Utility Knife<\/td><td>Scoring cable jackets<\/td><\/tr><tr><td>10<\/td><td>10 mm Socket <\/td><td>Ground Stud and side panels<\/td><\/tr><tr><td>11<\/td><td>Hoist, Forklift, or Crane<\/td><td>Unpacking and lifting <span translate=\"no\">Seakeeper<\/span> 10 into position<\/td><\/tr><tr><td>12<\/td><td>Drill \/ Drill Press<\/td><td>Bolt hole penetrations for bolt-in installations<\/td><\/tr><tr><td>13<\/td><td>Threaded Insert Installation Kit<\/td><td>Tap and install threaded inserts for bolt-in installation<\/td><\/tr><tr><td>14<\/td><td>1\/2&#8243; Drive Torque Wrench<\/td><td>Foundation bolts<\/td><\/tr><tr><td>15<\/td><td>Fish Tape<\/td><td>Cable pulls<\/td><\/tr><tr><td>16<\/td><td>Hole Saw<\/td><td>Thru-hull fittings<\/td><\/tr><\/tbody><\/table><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>5.2.1 Required Supplies Needed for Seakeeper Installation(Not Supplied with the Seakeeper) Item Description Qty Installation Manual Reference Section Other Reference System 1 Adhesive and cleaning supplies for bonding to hull AR Mechanical Installation Mechanical 2 Soundproofing Considerations AR Selection of Installation Location Mechanical 3 Spreader bar for lifting Seakeeper 1 Transport and Unpacking P\/N 11015 [&hellip;]<\/p>\n","protected":false},"author":9,"featured_media":0,"parent":20686,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"manual":[365],"model":[],"document_type":[],"hidden":[],"class_list":["post-20690","page","type-page","status-publish","hentry","manual-seakeeper-10-installation-manual-90841-2"],"acf":[],"_links":{"self":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/20690","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/comments?post=20690"}],"version-history":[{"count":5,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/20690\/revisions"}],"predecessor-version":[{"id":21099,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/20690\/revisions\/21099"}],"up":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/20686"}],"wp:attachment":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/media?parent=20690"}],"wp:term":[{"taxonomy":"manual","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/manual?post=20690"},{"taxonomy":"model","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/model?post=20690"},{"taxonomy":"document_type","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/document_type?post=20690"},{"taxonomy":"hidden","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/hidden?post=20690"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}