{"id":17446,"date":"2025-01-08T19:06:04","date_gmt":"2025-01-08T19:06:04","guid":{"rendered":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-9-installation-manual-90222-11-s-n-9-233-4900-to-current-copy\/mechanical-installation\/bolt-in-installation\/check-and-preparation-of-hull-structure\/"},"modified":"2025-01-09T13:31:57","modified_gmt":"2025-01-09T13:31:57","slug":"check-and-preparation-of-hull-structure","status":"publish","type":"page","link":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-10-installation-manual\/mechanical-installation\/bolt-in-installation\/check-and-preparation-of-hull-structure\/","title":{"rendered":"2.3.1  Preparation of Vessel Structure"},"content":{"rendered":"\n<p><span translate=\"no\">Seakeeper<\/span> provided mounting hardware is intended to apply to typical installation arrangements. However, each installation, especially custom aftermarket foundations, should be thoroughly reviewed to ensure the provided hardware meets the required thread engagement for the <span translate=\"no\">Seakeeper<\/span> unit being installed. The mounting bolt thread engagement requirements are outlined in the Installation Manuals and Installation Details Drawings for each <span translate=\"no\">Seakeeper<\/span> model. This also applies to <span translate=\"no\">Seakeeper<\/span> model adapter kits and OEM built frames where the bolt hole depth should be checked to ensure the bolts will not bottom, preventing the bolts from achieving the intended preload.<\/p>\n\n\n\n<p>When the <span translate=\"no\">Seakeeper<\/span> provided hardware is not appropriate, the bolt specification (diameter and thread pitch) and grade should be matched in the required length and used with the <span translate=\"no\">Seakeeper<\/span> provided washers. Mounting bolts should always be torqued to the <span translate=\"no\">Seakeeper<\/span> specification. All <span translate=\"no\">Seakeeper<\/span> provided bolts are metric course thread. Hardware specifications are also listed in the Installation Manuals and Installation Details Drawings.<\/p>\n\n\n\n<p>Refer to <span translate=\"no\">Seakeeper<\/span> <em>Drawing No. 90834 \u2013 <span translate=\"no\">Seakeeper<\/span> 10 Bolt-In Installation Details<\/em>. Important dimensional and load information is given in this drawing that will impact the design details of the structure that will receive the <span translate=\"no\">Seakeeper<\/span>. It is assumed that a proper structural analysis has been performed for the hull structure to which the <span translate=\"no\">Seakeeper<\/span> will be fastened to ensure proper strength margins for the loads the <span translate=\"no\">Seakeeper<\/span> will create during operation. <span translate=\"no\">Seakeeper<\/span> recommends a safety factor of 3.0.<\/p>\n\n\n\n<p>Marine-grade aluminum (6061-T6, or equivalent) bar stock is recommended for both blind hole tapping and thru-bolt installations. For blind-hold installations, helical threaded inserts (Helicoils) with a length of 1.5 x bolt-diameter (21 mm) are required to ensure the strength of the tapped holes exceeds that of the mounting bolts (Grade 10.9), which ensures a secure bolted connection between the <span translate=\"no\">Seakeeper<\/span> and hull structure.<\/p>\n\n\n\n<hr class=\"wp-block-separator is-style-wide\"\/>\n\n\n\n<p>The <span translate=\"no\">Seakeeper<\/span> supporting structure should be parallel to the vessel waterline, with up to 2 degrees of allowance for trim. It must be installed in a fore- and aft orientation parallel to the vessel centerline.<\/p>\n\n\n\n<p><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-red-color\"><strong>In addition, the four areas on top of the structure on which the <span translate=\"no\">Seakeeper<\/span> frame and isolation gaskets will rest need to be co-planar within .06 in. (1.5 mm) to minimize potential distortion of the <span translate=\"no\">Seakeeper<\/span> support frame when installed. The isolation gaskets are only used when the <span translate=\"no\">Seakeeper<\/span> 10 is mounted to a dissimilar metal structure.<\/strong><\/mark><\/p>\n\n\n\n<p><span translate=\"no\">Seakeeper<\/span> provides an installation template kit, P\/N 90839, which contains plates matching the mating surfaces of the four feet on the <span translate=\"no\">Seakeeper<\/span>\u2019s frame. These plates have 4 holes located at the same centers as the mounting holes on the <span translate=\"no\">Seakeeper<\/span>. The fixture locates the hole patterns at the proper spacing both in the forward-aft direction and the port-starboard direction. See Figure 6 below. Once assembled, the fixture can be used to check clearances and alignment of the hull structure.<\/p>\n\n\n\n<p><strong>Note: Do NOT use the installation fixture to establish <span translate=\"no\">Seakeeper<\/span> envelope dimensions. Refer to <em>Drawing No. 90834 \u2013 <span translate=\"no\">Seakeeper<\/span> 10 Bolt-In Installation Details<\/em>, for envelope dimensions. A 3-D model of the <span translate=\"no\">Seakeeper<\/span> is available on the <span translate=\"no\">Seakeeper<\/span> Technical Library<\/strong> (<a href=\"http:\/\/www.seakeeper.com\/technical-library\/\">www.seakeeper.com\/technical-library\/<\/a>) <strong>to aid in designing the <span translate=\"no\">Seakeeper<\/span> foundation and the space around the <span translate=\"no\">Seakeeper<\/span>.<\/strong><\/p>\n\n\n\n<p class=\"has-text-align-center\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-red-color\">NOTE: MAKE SURE NO OBSTRUCTIONS FROM THE HULL STRUCTURE CAN BE SEEN WITHIN THE INSIDE OF THE INSTALLATION TEMPLATE KIT (INSIDE THE MARKED RED LINES) AS SEEN IN FIGURE 6. REFERENCE SEAKEEPER DRAWING NO. 90834 \u2013 SEAKEEPER 10 BOLT-IN INSTALLATION DETAILS.<\/mark><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1393\" height=\"573\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Installation-Fixture-90839.png\" alt=\"\" class=\"wp-image-19709\" style=\"aspect-ratio:1.5078534031413613;width:526px;height:auto\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Installation-Fixture-90839.png 1393w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Installation-Fixture-90839-768x316.png 768w\" sizes=\"auto, (max-width: 1393px) 100vw, 1393px\" \/><figcaption class=\"wp-element-caption\"><em><strong>Figure 6 \u2013 <\/strong>View of Installation Fixture<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1849\" height=\"724\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/10_5-IM-Bolt-Clearances.png\" alt=\"\" class=\"wp-image-18184\" style=\"width:874px;height:auto\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/10_5-IM-Bolt-Clearances.png 1849w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/10_5-IM-Bolt-Clearances-768x301.png 768w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/10_5-IM-Bolt-Clearances-1536x601.png 1536w\" sizes=\"auto, (max-width: 1849px) 100vw, 1849px\" \/><figcaption class=\"wp-element-caption\"><em><strong>Figure 7<\/strong> &#8211; Installation Clearances<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<p class=\"has-text-align-center\"><strong><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-red-color\">CAUTION: Tight clearances from cable guide bands to hull structure. <\/mark><br><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-red-color\">See above figure for dimensions and reference <\/mark><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-red-color\"><span translate=\"no\">Seakeeper<\/span> Drawing No. 90834 \u2013 <span translate=\"no\">Seakeeper<\/span> 10 Bolt-In Installation Details<\/mark> <mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-red-color\">for complete <span translate=\"no\">Seakeeper<\/span> 10 envelope.<\/mark><\/strong><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Seakeeper provided mounting hardware is intended to apply to typical installation arrangements. However, each installation, especially custom aftermarket foundations, should be thoroughly reviewed to ensure the provided hardware meets the required thread engagement for the Seakeeper unit being installed. The mounting bolt thread engagement requirements are outlined in the Installation Manuals and Installation Details Drawings [&hellip;]<\/p>\n","protected":false},"author":9,"featured_media":0,"parent":17444,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"manual":[322],"model":[],"document_type":[],"hidden":[],"class_list":["post-17446","page","type-page","status-publish","hentry","manual-seakeeper-10-installation-manual"],"acf":[],"_links":{"self":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/17446","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/comments?post=17446"}],"version-history":[{"count":14,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/17446\/revisions"}],"predecessor-version":[{"id":19802,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/17446\/revisions\/19802"}],"up":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/17444"}],"wp:attachment":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/media?parent=17446"}],"wp:term":[{"taxonomy":"manual","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/manual?post=17446"},{"taxonomy":"model","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/model?post=17446"},{"taxonomy":"document_type","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/document_type?post=17446"},{"taxonomy":"hidden","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/hidden?post=17446"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}