{"id":17263,"date":"2023-11-06T12:55:33","date_gmt":"2023-11-06T12:55:33","guid":{"rendered":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-40-installation-manual-90715-1-copy\/electrical-installation\/electrical-equipment-power-connections-2\/"},"modified":"2024-01-17T13:12:55","modified_gmt":"2024-01-17T13:12:55","slug":"electrical-equipment-power-connections-2","status":"publish","type":"page","link":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-40-installation-manual-90715-2\/electrical-installation\/electrical-equipment-power-connections-2\/","title":{"rendered":"3.2  Electrical Equipment Power Connections"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" style=\"font-size:25px\">230 VAC Power Source Requirements<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>230 VAC (nominal), 1 Phase, 50\/60 Hz, 30 A<\/li>\n\n\n\n<li>With installations of more than one <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span>, a dedicated circuit breaker should be used for each <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> Motor Drive Box.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator is-style-wide\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" style=\"font-size:20px\">Drive Box AC Power Input Connection Instructions<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>AC Power Input Cable: 3 x 10 AWG (3 x 6 mm<sup>2<\/sup> CSA), 10 ft (3 m) length, (P\/N 20542) <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span>-supplied and pre-installed in Motor Drive Box.<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"655\" height=\"764\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SK40-MDB.jpg\" alt=\"\" class=\"wp-image-15248\" style=\"width:282px;height:328px\"\/><figcaption class=\"wp-element-caption\"><em><strong>Figure 17<\/strong> &#8211; Motor Drive VAC Input &amp; <\/em>Drive Power O<em>utput Cable Glands<\/em><\/figcaption><\/figure>\n<\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"868\" height=\"285\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Cable-2-Wire-Connections-at-AC-Power-Distribution-Panel.jpg\" alt=\"\" class=\"wp-image-4239\" style=\"width:411px;height:135px\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Cable-2-Wire-Connections-at-AC-Power-Distribution-Panel.jpg 868w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Cable-2-Wire-Connections-at-AC-Power-Distribution-Panel-768x252.jpg 768w\" sizes=\"auto, (max-width: 868px) 100vw, 868px\" \/><figcaption class=\"wp-element-caption\"><em><strong>Figure 18<\/strong> &#8211; AC Power Input Cable Wire Connections at AC Power Distribution Panel<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<ol class=\"wp-block-list\" start=\"2\">\n<li>For <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> 40, connect 230 VAC wires in AC Input Cable to a <strong>30 A<\/strong>, double-pole Circuit Breaker at an AC power distribution panel according to Figure 18 above.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator is-style-wide\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">24 VDC Power Input<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>One 24 VDC, 15 A (Customer supplied breaker) for <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> Control Power, <strong>AND<\/strong><\/li>\n\n\n\n<li>One 24 VDC, 20 A (Customer supplied breaker) for DC Seawater Pump.<\/li>\n\n\n\n<li>A dedicated breaker breaker should be used for each <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> control power and DC Seawater Pump source.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator is-style-wide\"\/>\n\n\n\n<h3 class=\"wp-block-heading has-medium-font-size\">DC Power Connection Instructions<\/h3>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\"><div class=\"wp-block-image\">\n<figure class=\"alignright size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"253\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/warning-icon.jpg\" alt=\"\" class=\"wp-image-1505\" style=\"width:159px;height:100px\"\/><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p><\/p>\n\n\n\n<p class=\"has-vivid-red-color has-text-color\"><strong>Reversing polarity on the DC power input to the <span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span> can result in damaging the electronics in the control system.<\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<ol class=\"wp-block-list\">\n<li>24 VDC, 2 x 12 AWG (3 x 4 mm<sup>2<\/sup> CSA) <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> supplied.<br>\n<ol class=\"wp-block-list\">\n<li>Install <span translate=\"no\"><span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span><\/span> provided DC Power Input Cable (P\/N 20248), <br>as shown in Drawing No. 90710 &#8211; <span translate=\"no\"><span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span><\/span> 40 Cable Block Diagram.<br>\n<ol class=\"wp-block-list\">\n<li>Route DC Power Input Cable to DC Power Distribution Panel.<\/li>\n\n\n\n<li>Terminate positive (B+, Red) conductor through dedicated over-current protection device (customer supplied) and a dedicated <span translate=\"no\"><span translate=\"no\"><span translate=\"no\"><span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span><\/span><\/span><\/span> isolation switch (customer supplied) then directly to battery plus terminal.<\/li>\n\n\n\n<li>Terminate negative (B-, Black) conductor directly to battery negative terminal or negative bus.<\/li>\n<\/ol>\n<\/li>\n\n\n\n<li>Before connecting DC Input Cable to <span translate=\"no\"><span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span><\/span>, check for proper voltage and polarity with a DC multimeter using Figure 19 below.<\/li>\n\n\n\n<li>Connect DC Input Cable to 24 VDC input receptacle on <span translate=\"no\"><span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span><\/span>.<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"627\" height=\"447\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/DC-Power-Input-Connector-Contact-Assignments-Front.jpg\" alt=\"\" class=\"wp-image-4255\" style=\"width:290px;height:206px\"\/><figcaption class=\"wp-element-caption\"><em><strong>Figure 19 \u2013 <\/strong>DC Power Input Connector Contact Assignments (front)<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\"><div class=\"wp-block-image\">\n<figure class=\"alignright size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"253\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/warning-icon.jpg\" alt=\"\" class=\"wp-image-1505\" style=\"width:158px;height:100px\"\/><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p><\/p>\n\n\n\n<p class=\"has-vivid-red-color has-text-color\"><strong>When energizing DC power for the first time, if ConnectBox does not power up immediately then disconnect and inspect connector polarity.<\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator is-style-wide\"\/>\n\n\n\n<h3 class=\"wp-block-heading has-medium-font-size\">DC Seawater Pump 24 VDC Power Input Connection Instructions<\/h3>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\"><div class=\"wp-block-image\">\n<figure class=\"alignright size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"406\" height=\"358\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/CAUTION.png\" alt=\"\" class=\"wp-image-10247\" style=\"width:119px;height:105px\"\/><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p><\/p>\n\n\n\n<p class=\"has-vivid-red-color has-text-color\"><strong>Connecting the DC Seawater Pump in any other manner than recommended by <span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span> may cause internal failure.<\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Install Seawater Pump Input Cable (P\/N 20248) to overcurrent protection corresponding to Seawater Pump selected as follows:<br>\n<ol class=\"wp-block-list\">\n<li>Connect the 12 AWG positive conductor (Red) through dedicated overcurrent protection device (Customer supplied), maximum of 20 A, to dedicated battery isolation switch.<\/li>\n\n\n\n<li>Connect 12 AWG negative conductor (Black) directly to battery negative terminal or DC main negative bus bar.<\/li>\n<\/ol>\n<\/li>\n\n\n\n<li>Before connecting Seawater Pump Input Cable to <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span>, check for proper voltage and polarity with a DC multimeter using Figure 20 below.<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"213\" height=\"148\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Figure-5.png\" alt=\"\" class=\"wp-image-9376\" style=\"width:279px;height:194px\"\/><figcaption class=\"wp-element-caption\"><em><strong>Figure 20<\/strong> &#8211; 24 VDC Seawater Pump Power Input<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<ol class=\"wp-block-list\" start=\"3\">\n<li>Connect Seawater Pump Input Cable to &#8220;SW Pump 24 VDC In&#8221; connector on the <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span>.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator is-style-wide\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">DC Seawater Pump 24 VDC Power Output Connection Instructions<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Connect Seawater Pump Output Cable (P\/N 20594) to the <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> 40 &#8220;SW Pump 24 VDC Out&#8221; for DC power output to the Seawater Pump.<br>\n<ol class=\"wp-block-list\">\n<li>Seawater Pump Output Cable is a 2 x 12 AWG cable, 16 ft (5 m) length, with a size 12 female Deutsch plug.<\/li>\n\n\n\n<li>Cable P\/N 20594 has two ring terminals for connection to DC Seawater Pump P\/N 30529. A cable option exists for attaching a Deutsch connector (as shown below). See Drawing 90710 &#8211; <span translate=\"no\"><span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span><\/span> 40 Cable Block Diagram notes for details.<\/li>\n<\/ol>\n<\/li>\n\n\n\n<li>Customer-supplied pumps rated at 24 VDC, 20 A maximum, customer supplied, must be configured with a Deutsch DTP-04 series, 2-pin male receptacle (Figure 21) to mate with the Seawater Pump Output Cable female connector.<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1636\" height=\"1312\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/DT04-2P-1.jpg\" alt=\"\" class=\"wp-image-12440\" style=\"width:290px;height:233px\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/DT04-2P-1.jpg 1636w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/DT04-2P-1-768x616.jpg 768w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/DT04-2P-1-1536x1232.jpg 1536w\" sizes=\"auto, (max-width: 1636px) 100vw, 1636px\" \/><figcaption class=\"wp-element-caption\"><strong><em>Figure 21<\/em><\/strong><em> &#8211; SW Pump Connector <\/em><br><em>(DTP04-2P)<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<ol class=\"wp-block-list\" start=\"3\">\n<li>Seawater Pump Output Cable must be routed and installed in the vessel from the <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> 40 &#8220;SW Pump 24 VDC Out&#8221; Deutsch connector to the DC Seawater Pump cable. See Figure 22 for details.<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1529\" height=\"520\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/DC-SW-Pp-Electrical-4.png\" alt=\"\" class=\"wp-image-17431\" style=\"width:741px;height:252px\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/DC-SW-Pp-Electrical-4.png 1529w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/DC-SW-Pp-Electrical-4-768x261.png 768w\" sizes=\"auto, (max-width: 1529px) 100vw, 1529px\" \/><figcaption class=\"wp-element-caption\"><em><strong>Figure 22<\/strong> &#8211; Seawater Pump Output Cable Details<\/em><\/figcaption><\/figure>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>230 VAC Power Source Requirements Drive Box AC Power Input Connection Instructions 24 VDC Power Input DC Power Connection Instructions Reversing polarity on the DC power input to the Seakeeper can result in damaging the electronics in the control system. When energizing DC power for the first time, if ConnectBox does not power up immediately [&hellip;]<\/p>\n","protected":false},"author":9,"featured_media":0,"parent":17259,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"manual":[318],"model":[],"document_type":[],"hidden":[],"class_list":["post-17263","page","type-page","status-publish","hentry","manual-seakeeper-40-installation-manual-90715-2"],"acf":[],"_links":{"self":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/17263","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/comments?post=17263"}],"version-history":[{"count":8,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/17263\/revisions"}],"predecessor-version":[{"id":18113,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/17263\/revisions\/18113"}],"up":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/17259"}],"wp:attachment":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/media?parent=17263"}],"wp:term":[{"taxonomy":"manual","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/manual?post=17263"},{"taxonomy":"model","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/model?post=17263"},{"taxonomy":"document_type","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/document_type?post=17263"},{"taxonomy":"hidden","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/hidden?post=17263"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}