{"id":14830,"date":"2023-05-04T12:50:07","date_gmt":"2023-05-04T12:50:07","guid":{"rendered":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-2-installation-manual-90488-4-preliminary\/start-up\/5-2-required-supplies-for-seakeeper-installation\/"},"modified":"2023-05-04T13:35:02","modified_gmt":"2023-05-04T13:35:02","slug":"5-2-required-supplies-for-seakeeper-installation","status":"publish","type":"page","link":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-2-installation-manual\/start-up\/5-2-required-supplies-for-seakeeper-installation\/","title":{"rendered":"5.2  Supplies Required for Installation"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" id=\"block-9bc5ee1a-d107-4dd0-86a2-daa50374f570\" style=\"font-size:25px\">(Not Supplied With the <span translate=\"no\">Seakeeper<\/span>)<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Item<\/th><th>Description<\/th><th class=\"has-text-align-center\" data-align=\"center\">Qty<\/th><th class=\"has-text-align-left\" data-align=\"left\">Installation Manual Reference Section<\/th><th>Other Reference<\/th><th>System<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td>Soundproofing Considerations<\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><td class=\"has-text-align-left\" data-align=\"left\"><a rel=\"noreferrer noopener\" href=\"https:\/\/manuals.seakeeper.com\/seakeeper-2-installation-manual\/mechanical-installation\/selection-of-seakeeper-installation-location\/\" data-type=\"URL\" data-id=\"https:\/\/manuals.seakeeper.com\/seakeeper-2-installation-manual\/mechanical-installation\/selection-of-seakeeper-installation-location\/\" target=\"_blank\">Selection of Installation Location<\/a><\/td><td><\/td><td>Mechanical<\/td><\/tr><tr><td>2<\/td><td>Spreader bar for lifting the <span translate=\"no\">Seakeeper<\/span><\/td><td class=\"has-text-align-center\" data-align=\"center\">1<\/td><td class=\"has-text-align-left\" data-align=\"left\"><a rel=\"noreferrer noopener\" href=\"https:\/\/manuals.seakeeper.com\/seakeeper-2-installation-manual\/mechanical-installation\/transport-and-unpacking-2\/\" data-type=\"URL\" data-id=\"https:\/\/manuals.seakeeper.com\/seakeeper-2-installation-manual\/mechanical-installation\/transport-and-unpacking-2\/\" target=\"_blank\">Transport and Unpacking<\/a><\/td><td><\/td><td>Mechanical<\/td><\/tr><tr><td>3<\/td><td><span translate=\"no\">Seakeeper<\/span> 2 Fixture Kit<\/td><td class=\"has-text-align-center\" data-align=\"center\">1<\/td><td class=\"has-text-align-left\" data-align=\"left\">Bolt-In Installation<\/td><td>P\/N 90473<\/td><td>Mechanical<\/td><\/tr><tr><td>4<\/td><td>Hose clamps for seawater plumbing to \u00be in. (19 mm) hose barb (2 per hose barb)<\/td><td class=\"has-text-align-center\" data-align=\"center\">4<\/td><td class=\"has-text-align-left\" data-align=\"left\"><a rel=\"noreferrer noopener\" href=\"https:\/\/manuals.seakeeper.com\/seakeeper-2-installation-manual\/cooling-installation\/connecting-seawater-to-heat-exchanger\/\" data-type=\"URL\" data-id=\"https:\/\/manuals.seakeeper.com\/seakeeper-2-installation-manual\/cooling-installation\/connecting-seawater-to-heat-exchanger\/\" target=\"_blank\">Connecting Seawater to Heat Exchanger<\/a><\/td><td>Dwg 90490<\/td><td>Cooling<\/td><\/tr><tr><td>5<\/td><td>3\/4 in. (19 mm) ID Hose<\/td><td class=\"has-text-align-center\" data-align=\"center\">AR<\/td><td class=\"has-text-align-left\" data-align=\"left\">Connecting Seawater to Heat Exchanger<\/td><td>Dwg 90490<\/td><td>Cooling<\/td><\/tr><tr><td>6<\/td><td>Seacock Valve<\/td><td class=\"has-text-align-center\" data-align=\"center\">1<\/td><td class=\"has-text-align-left\" data-align=\"left\">Connecting Seawater to Heat Exchanger<\/td><td>Dwg 90490<\/td><td>Cooling<\/td><\/tr><tr><td>7<\/td><td>Seawater Strainer (included with <span translate=\"no\">Seakeeper<\/span> Seawater Pump (P\/N 30331))<\/td><td class=\"has-text-align-center\" data-align=\"center\">1<\/td><td class=\"has-text-align-left\" data-align=\"left\">Connecting Seawater to Heat Exchanger<\/td><td>Dwg 90490<\/td><td>Cooling<\/td><\/tr><tr><td>8<\/td><td>Through-Hull Fittings (1 high speed pick up and 1 overboard discharge)<\/td><td class=\"has-text-align-center\" data-align=\"center\">2<\/td><td class=\"has-text-align-left\" data-align=\"left\">Connecting Seawater to Heat Exchanger<\/td><td>Dwg 90490<\/td><td>Cooling<\/td><\/tr><tr><td>9<\/td><td>M6 terminal lug for grounding <span translate=\"no\">Seakeeper<\/span> at rear brace<\/td><td class=\"has-text-align-center\" data-align=\"center\">1<\/td><td class=\"has-text-align-left\" data-align=\"left\"><a rel=\"noreferrer noopener\" href=\"https:\/\/manuals.seakeeper.com\/seakeeper-2-installation-manual\/electrical-installation\/electrical-equipment-ground-connections\/\" data-type=\"URL\" data-id=\"https:\/\/manuals.seakeeper.com\/seakeeper-2-installation-manual\/electrical-installation\/electrical-equipment-ground-connections\/\" target=\"_blank\">Electrical Equipment Ground Connections<\/a><\/td><td> Dwg 90470 <\/td><td>Electrical<\/td><\/tr><tr><td>10<\/td><td>Cable, 4 AWG, for grounding <span translate=\"no\">Seakeeper<\/span> at foundation to vessel ground (used with item 5)<\/td><td class=\"has-text-align-center\" data-align=\"center\">AR<\/td><td class=\"has-text-align-left\" data-align=\"left\"><a rel=\"noreferrer noopener\" href=\"https:\/\/manuals.seakeeper.com\/seakeeper-2-installation-manual\/electrical-installation\/electrical-equipment-ground-connections\/\" data-type=\"URL\" data-id=\"https:\/\/manuals.seakeeper.com\/seakeeper-2-installation-manual\/electrical-installation\/electrical-equipment-ground-connections\/\" target=\"_blank\">Electrical Equipment Ground Connections<\/a> <\/td><td>Dwg 90470<\/td><td>Electrical<\/td><\/tr><tr><td>11<\/td><td>Seawater pump, 12 VDC, 15A max<\/td><td class=\"has-text-align-center\" data-align=\"center\">1<\/td><td class=\"has-text-align-left\" data-align=\"left\"><a rel=\"noreferrer noopener\" href=\"https:\/\/manuals.seakeeper.com\/seakeeper-2-installation-manual\/electrical-installation\/electrical-equipment-power-connections-2\/dc-seawater-pump-12v-power-output\/\" data-type=\"URL\" data-id=\"https:\/\/manuals.seakeeper.com\/seakeeper-2-installation-manual\/electrical-installation\/electrical-equipment-power-connections-2\/dc-seawater-pump-12v-power-output\/\" target=\"_blank\">Electrical Equipment DC Pump Power<\/a> <\/td><td> Dwg 90470 <\/td><td>Electrical<\/td><\/tr><tr><td>12<\/td><td>100 A Circuit breaker for Conductor 1<\/td><td class=\"has-text-align-center\" data-align=\"center\">1<\/td><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/manuals.seakeeper.com\/seakeeper-2-installation-manual\/electrical-installation\/electrical-equipment-power-connections-2\/high-current-12v-power-input-2\/\" data-type=\"URL\" target=\"_blank\" rel=\"noreferrer noopener\">Electrical Equipment High Current Power Input<\/a><\/td><td> Dwg 90470 <\/td><td>Electrical<\/td><\/tr><tr><td>13<\/td><td>15 A Circuit breaker for Low Current Power and DC Seawater Pump<\/td><td class=\"has-text-align-center\" data-align=\"center\">2<\/td><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/manuals.seakeeper.com\/seakeeper-2-installation-manual\/electrical-installation\/electrical-equipment-power-connections-2\/low-current-12v-power-input\/\" data-type=\"URL\" target=\"_blank\" rel=\"noreferrer noopener\">Electrical Equipment Low Current Power Input<\/a> <\/td><td> Dwg 90470 <\/td><td>Electrical<\/td><\/tr><tr><td>14<\/td><td>Battery Isolator Switch<\/td><td class=\"has-text-align-center\" data-align=\"center\">1<\/td><td class=\"has-text-align-left\" data-align=\"left\">Electrical Equipment Power Connections<\/td><td>Dwg 90470<\/td><td>Electrical<\/td><\/tr><tr><td>15<\/td><td>Marine Sealant<\/td><td class=\"has-text-align-center\" data-align=\"center\">AR<\/td><td class=\"has-text-align-left\" data-align=\"left\">Bolt-In Installation<\/td><td>DWG 90487<\/td><td>Mechanical<\/td><\/tr><tr><td>16<\/td><td>Nickel-based Anti-Seize<\/td><td class=\"has-text-align-center\" data-align=\"center\">AR<\/td><td class=\"has-text-align-left\" data-align=\"left\">Bolt-In Installation<\/td><td>DWG 90487<\/td><td>Mechanical<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\"><br><strong>AR = As Required<br>Dwg = Drawing<\/strong><\/figcaption><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>(Not Supplied With the Seakeeper) Item Description Qty Installation Manual Reference Section Other Reference System 1 Soundproofing Considerations Selection of Installation Location Mechanical 2 Spreader bar for lifting the Seakeeper 1 Transport and Unpacking Mechanical 3 Seakeeper 2 Fixture Kit 1 Bolt-In Installation P\/N 90473 Mechanical 4 Hose clamps for seawater plumbing to \u00be in. [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":13014,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"manual":[279],"model":[],"document_type":[],"hidden":[],"class_list":["post-14830","page","type-page","status-publish","hentry","manual-seakeeper-2-installation-manual"],"acf":[],"_links":{"self":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/14830","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/comments?post=14830"}],"version-history":[{"count":4,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/14830\/revisions"}],"predecessor-version":[{"id":14839,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/14830\/revisions\/14839"}],"up":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/13014"}],"wp:attachment":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/media?parent=14830"}],"wp:term":[{"taxonomy":"manual","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/manual?post=14830"},{"taxonomy":"model","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/model?post=14830"},{"taxonomy":"document_type","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/document_type?post=14830"},{"taxonomy":"hidden","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/hidden?post=14830"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}