{"id":14462,"date":"2023-04-05T16:10:50","date_gmt":"2023-04-05T16:10:50","guid":{"rendered":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-3-75-operation-manual-90xxx-1-copy-copy\/specifications-and-summary\/"},"modified":"2023-06-19T12:54:00","modified_gmt":"2023-06-19T12:54:00","slug":"specifications-and-summary","status":"publish","type":"page","link":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-3-operation-manual-90379-5\/specifications-and-summary\/","title":{"rendered":"7.0  Specifications and Summary"},"content":{"rendered":"\n<figure class=\"wp-block-table\"><table><thead><tr><th><\/th><th><span translate=\"no\">Seakeeper<\/span> 3<\/th><\/tr><\/thead><tbody><tr><td><strong>Rated RPM<\/strong><\/td><td>8,450 RPM<\/td><\/tr><tr><td><strong>Angular Momentum at Rated RPM<\/strong><\/td><td>3,000 N-m-s<\/td><\/tr><tr><td><strong>Anti-Rolling Torque at Rated RPM<\/strong><\/td><td>7,853 N-m<\/td><\/tr><tr><td><strong>Spool-up Time to Rated Speed<\/strong><\/td><td>50 minutes (8,450 RPM)<\/td><\/tr><tr><td><strong>Spool-up Time to Stabilization <\/strong><\/td><td>36 minutes (7,185 RPM)<\/td><\/tr><tr><td><strong>Spool-up Power<\/strong><br>DC Motor<\/td><td>900 Watts Max<\/td><\/tr><tr><td><strong>Operating Power<\/strong><br>DC (Sea state dependent)<\/td><td>400 &#8211; 900 Watts<\/td><\/tr><tr><td><strong>Voltage<\/strong><br>DC Input<\/td><td>12 VDC @ 85 Amps (Spool-up)<\/td><\/tr><tr><td>Seawater Pump Power Input<\/td><td>12 VDC @ 15 Amps maximum<\/td><\/tr><tr><td><strong>Seawater Supply to Heat Exchanger<\/strong><\/td><td>2 GPM (7.6 LPM) minimum<br>6 GPM (22.7 LPM) maximum<\/td><\/tr><tr><td><strong>Ambient Air Temperature<\/strong><\/td><td>32\u02da &#8211; 140\u02daF (0 &#8211; 60\u02daC)<\/td><\/tr><tr><td><strong>Weight<\/strong><\/td><td>550 lbs (249 kg)<\/td><\/tr><tr><td><strong>Envelope Dimensions<\/strong><\/td><td>26.8 L x 27.0 W x 23.1 H (inches)<br>0.680 L x 0.688 W x 0.587 H (meters)<\/td><\/tr><tr><td><strong>Noise Output<\/strong><\/td><td>&lt; 72 dBC at 1 meter<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/CB-Rollout-6-1-3000x2686.jpg\" alt=\"\" class=\"wp-image-14468\" width=\"534\" height=\"504\"\/><\/figure>\n<\/div>\n\n\n\n\n<p><strong>Arrangement<\/strong><br>The <span translate=\"no\">Seakeeper<\/span> 3 consists of the Flywheel, Enclosure, Foundation, Electronics, Brake, Cooling, and Cover Subsystems.<br><br><strong>Installation Location<br><\/strong>The <span translate=\"no\">Seakeeper<\/span> is a torque device and does not have to be installed in a specific hull location or on the centerline. However, the <span translate=\"no\">Seakeeper<\/span> should <strong>not<\/strong> be installed forward of the longitudinal center of gravity to minimize high acceleration loading due to hull\/wave impacts during operation at high speed or in large waves.<br><br><strong>Mounting Dimensions<br><\/strong>See Drawing No. 90374 \u2013 <span translate=\"no\">Seakeeper<\/span> 3 Bolt-In Installation Details.<br><br><strong>Loads<\/strong><br>The installer is responsible for designing the foundation to which the <span translate=\"no\">Seakeeper<\/span> is attached and for ensuring that this foundation can safely transfer the concentrated <span translate=\"no\">Seakeeper<\/span> loads from the frame to the adjacent hull structure. Loads that the <span translate=\"no\">Seakeeper<\/span> imposes on the hull structure are explained on Drawing No. 90374 \u2013 <span translate=\"no\">Seakeeper<\/span> 3 Bolt-In Installation Details; these loads do NOT include vessel motion accelerations, such as vertical slam loads which can be high for higher speed vessels.<br><br><strong>Cooling<\/strong><br>The <span translate=\"no\">Seakeeper<\/span> bearings, Motor Drive Box, and hydraulic manifold are cooled by a closed water \/ glycol mix cooling loop that incorporates a seawater heat exchanger. The installer is responsible for providing 2 &#8211; 6 GPM (7.6 &#8211; 22.7 LPM) raw water at ambient sea temperature and a maximum pressure of 20 psi (1.4 bar) to the heat exchanger.<br><br><strong>Electrical<\/strong><br>The installer is responsible for supplying 12 VDC at 100 A service to the Motor Drive Box, 12 VDC at 15 A service to the <span translate=\"no\">Seakeeper<\/span> Control System, and 12 VDC at 15 A service to the Seawater Pump. Separate circuit breakers should be used for each Motor Drive Box in multiple <span translate=\"no\">Seakeeper<\/span> installations. Similarly, separate circuit breakers should be used for each <span translate=\"no\">Seakeeper<\/span> Control System and Seawater Pump in multiple <span translate=\"no\">Seakeeper<\/span> installations.<br><br><strong>Operator Controls<br><\/strong>A compatible MFD or a 5&#8243; Touch Display is used to start, operate, monitor, and shutdown the <span translate=\"no\">Seakeeper<\/span> from the helm. The operator may also use the local ConnectBox interface on the <span translate=\"no\">Seakeeper<\/span> 3 to start and shutdown the <span translate=\"no\">Seakeeper<\/span>.<br><br><strong>Performance<\/strong><br>Reduction of boat roll is a function of the boat\u2019s displacement, transverse metacentric height (GM<sub>T<\/sub>) and hull damping as well as the operating conditions (speed and heading with respect to waves) and sea state. The <span translate=\"no\">Seakeeper<\/span> controller regulates the active hydraulic brake to ensure the <span translate=\"no\">Seakeeper<\/span>\u2019s anti-roll torque is maximized regardless of hull characteristics or operating conditions.<br><br><strong>Alarm and Monitoring<\/strong><br>Sensors, alarms and shutdowns are provided to allow unattended operation. Sensors measure <span translate=\"no\">Seakeeper<\/span> and drive temperatures, vacuum pressure, gimbal angle, brake pressure, and ship motion. The <span translate=\"no\">Seakeeper<\/span> controller sends sensor values and alarm information to the display and also locks the brake and shuts down the motor drive in the event of an alarm condition. <span translate=\"no\">Seakeeper<\/span> operating history during faults or alarms is recorded in the controller\u2019s memory for subsequent recall if service is needed. <span translate=\"no\">Seakeeper<\/span> may access the <span translate=\"no\">Seakeeper<\/span>\u2019s software to gather run hours, bearing loading, and hull slamming information.<br><br><strong>Safety<\/strong><br>The brake automatically locks the <span translate=\"no\">Seakeeper<\/span> so it cannot generate excessive anti-rolling torque loads in the event of a system fault or alarm, loss of electrical power or loss of brake pressure. The brake can be locked from the Display or by shutting off AC and DC power at the supply breakers.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Seakeeper 3 Rated RPM 8,450 RPM Angular Momentum at Rated RPM 3,000 N-m-s Anti-Rolling Torque at Rated RPM 7,853 N-m Spool-up Time to Rated Speed 50 minutes (8,450 RPM) Spool-up Time to Stabilization 36 minutes (7,185 RPM) Spool-up PowerDC Motor 900 Watts Max Operating PowerDC (Sea state dependent) 400 &#8211; 900 Watts VoltageDC Input 12 [&hellip;]<\/p>\n","protected":false},"author":9,"featured_media":0,"parent":14399,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"manual":[300],"model":[],"document_type":[],"hidden":[],"class_list":["post-14462","page","type-page","status-publish","hentry","manual-seakeeper-3-operation-manual-90379-5"],"acf":[],"_links":{"self":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/14462","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/comments?post=14462"}],"version-history":[{"count":6,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/14462\/revisions"}],"predecessor-version":[{"id":14988,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/14462\/revisions\/14988"}],"up":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/14399"}],"wp:attachment":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/media?parent=14462"}],"wp:term":[{"taxonomy":"manual","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/manual?post=14462"},{"taxonomy":"model","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/model?post=14462"},{"taxonomy":"document_type","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/document_type?post=14462"},{"taxonomy":"hidden","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/hidden?post=14462"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}