{"id":14240,"date":"2023-03-17T16:09:11","date_gmt":"2023-03-17T16:09:11","guid":{"rendered":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-3-installation-manual-90378-7-sk3-cbro-draft\/4-0-cooling-installation\/4-1-cooling-installation-introduction\/"},"modified":"2025-06-17T17:25:51","modified_gmt":"2025-06-17T17:25:51","slug":"4-1-cooling-installation-introduction","status":"publish","type":"page","link":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-3-installation-manual-90378-7\/4-0-cooling-installation\/4-1-cooling-installation-introduction\/","title":{"rendered":"4.1  Cooling Installation Introduction"},"content":{"rendered":"\n<p>Reference Documents:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.seakeeper.com\/technical-library\/?type=&amp;product=&amp;search=90377\" target=\"_blank\" rel=\"noreferrer noopener\">90377 &#8211; <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> 3 Cable Block Diagram<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.seakeeper.com\/technical-library\/?type=&amp;product=&amp;search=90376\" target=\"_blank\" rel=\"noreferrer noopener\">90376 &#8211; <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> 3 Cooling Water Schematic<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.seakeeper.com\/technical-library\/?type=&amp;product=&amp;search=90191\" target=\"_blank\" rel=\"noreferrer noopener\">TB-90947 &#8211; Seawater Plumbing Best Practices<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.seakeeper.com\/technical-library\/?type=&amp;product=&amp;search=30331\" target=\"_blank\" rel=\"noreferrer noopener\">30331 &#8211; <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> DC Seawater Pump Assembly<\/a><\/li>\n<\/ul>\n\n\n\n<p>The <span translate=\"no\">Seakeeper<\/span> 3 is shipped with the cooling circuit (Figure 22) filled and ready for use. To cool the Closed-Loop glycol circuit on the unit, it requires a connection to a raw water pump, referred to as the seawater pump. When the on-demand cooling system requires cooling, the required seawater flow through the <span translate=\"no\">Seakeeper<\/span> 3 heat exchanger is between 2 and 6 GPM (7.6 and 22.7 LPM). Prior to operation, confirmation of the glycol level is recommended.<\/p>\n\n\n\n<p><span translate=\"no\">Seakeeper<\/span> offers a compatible self-priming DC Seawater Pump (P\/N 30331) prewired for<br>installation on the <span translate=\"no\">Seakeeper<\/span> 3 and covered under the standard <span translate=\"no\">Seakeeper<\/span> warranty. See Drawing No. 30331,<br><span translate=\"no\">Seakeeper<\/span> DC Seawater Pump Assembly for details and the <span translate=\"no\">Seakeeper<\/span> Options and Accessories Price List for pricing information.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"2221\" height=\"1415\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Picture11.png\" alt=\"\" class=\"wp-image-9055\" style=\"width:555px;height:354px\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Picture11.png 2221w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Picture11-768x489.png 768w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Picture11-1536x979.png 1536w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Picture11-2048x1305.png 2048w\" sizes=\"auto, (max-width: 2221px) 100vw, 2221px\" \/><figcaption class=\"wp-element-caption\"><em><strong>Figure 22 &#8211;<\/strong> <span translate=\"no\">Seakeeper<\/span> 3 Cooling Components<\/em><\/figcaption><\/figure>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Reference Documents: The Seakeeper 3 is shipped with the cooling circuit (Figure 22) filled and ready for use. To cool the Closed-Loop glycol circuit on the unit, it requires a connection to a raw water pump, referred to as the seawater pump. When the on-demand cooling system requires cooling, the required seawater flow through the [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":14199,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"manual":[293],"model":[],"document_type":[],"hidden":[],"class_list":["post-14240","page","type-page","status-publish","hentry","manual-seakeeper-3-installation-manual-90378-7"],"acf":[],"_links":{"self":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/14240","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/comments?post=14240"}],"version-history":[{"count":4,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/14240\/revisions"}],"predecessor-version":[{"id":20167,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/14240\/revisions\/20167"}],"up":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/14199"}],"wp:attachment":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/media?parent=14240"}],"wp:term":[{"taxonomy":"manual","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/manual?post=14240"},{"taxonomy":"model","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/model?post=14240"},{"taxonomy":"document_type","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/document_type?post=14240"},{"taxonomy":"hidden","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/hidden?post=14240"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}