{"id":14177,"date":"2023-03-17T12:05:18","date_gmt":"2023-03-17T12:05:18","guid":{"rendered":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-3-installation-manual-90378-7-sk3-cbro-draft\/2-0-mechanical-installation\/2-2-selection-of-installation-location\/"},"modified":"2023-06-15T11:15:57","modified_gmt":"2023-06-15T11:15:57","slug":"2-2-selection-of-installation-location","status":"publish","type":"page","link":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-3-installation-manual-90378-7\/2-0-mechanical-installation\/2-2-selection-of-installation-location\/","title":{"rendered":"2.2  Selection of Installation Location"},"content":{"rendered":"\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/CAUTION.png\" alt=\"\" class=\"wp-image-10247\" width=\"114\" height=\"100\"\/><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p class=\"has-vivid-red-color has-text-color\"><strong><span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span> can only assess installation location regarding its impact on <span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span> operation and serviceability. <span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span> cannot  determine how the installation location will affect the vessel static or directional stability other than cyclic roll reduction. The Installer is responsible for considering the <span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span> \u2019s effect on the CG location, trim, overall stability, and performance of the vessel.<\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<p>Selection of mounting location of the <span translate=\"no\">Seakeeper<\/span> should consider the following desirable features:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Provide adequate clearance for all recommended scheduled maintenance and any repairs that may be necessary, as shown in Figure 4 and installation drawings.<\/li>\n\n\n\n<li>The <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> should be installed in a dry space to minimize effects of corrosion.<\/li>\n\n\n\n<li>Installed near the vessel\u2019s longitudinal center of gravity (LCG) to minimize effects on trim and performance in various loading conditions.<\/li>\n\n\n\n<li>Overhead access or sufficient clearance for removal \/ re-installation of the <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> for overhaul in future years.<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/90374-PG-3-OF-5-Clearances-2.png\" alt=\"\" class=\"wp-image-9003\" width=\"451\" height=\"302\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/90374-PG-3-OF-5-Clearances-2.png 1222w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/90374-PG-3-OF-5-Clearances-2-768x514.png 768w\" sizes=\"auto, (max-width: 451px) 100vw, 451px\" \/><\/figure>\n<\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SK3-IM-Mech-Figure-2-2.jpg\" alt=\"\" class=\"wp-image-10890\" width=\"480\" height=\"306\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SK3-IM-Mech-Figure-2-2.jpg 1287w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SK3-IM-Mech-Figure-2-2-768x491.jpg 768w\" sizes=\"auto, (max-width: 480px) 100vw, 480px\" \/><figcaption class=\"wp-element-caption\"><em><strong>Figure 4 &#8211; <\/strong><span translate=\"no\">Seakeeper<\/span> 3 Installed Clearance Considerations<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<p>Refer to Figure 5 for recommended clearances to transverse or longitudinal beams. Clearances aft of the<br><span translate=\"no\">Seakeeper<\/span> are shown to provide access for regular scheduled maintenance.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SK3-IM-Mech-Fig-3.jpg\" alt=\"\" class=\"wp-image-13499\" width=\"510\" height=\"386\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SK3-IM-Mech-Fig-3.jpg 1057w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SK3-IM-Mech-Fig-3-768x582.jpg 768w\" sizes=\"auto, (max-width: 510px) 100vw, 510px\" \/><\/figure>\n<\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SK3-IM-Mech-Fig-3a.jpg\" alt=\"\" class=\"wp-image-13500\" width=\"514\" height=\"313\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SK3-IM-Mech-Fig-3a.jpg 1338w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SK3-IM-Mech-Fig-3a-768x468.jpg 768w\" sizes=\"auto, (max-width: 514px) 100vw, 514px\" \/><figcaption class=\"wp-element-caption\"><strong><em>Figure 5 &#8211; <\/em><\/strong><em><span translate=\"no\">Seakeeper<\/span> 3 Beams Clearance Considerations<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<h3 class=\"wp-block-heading\">2.2.1 Noise \/ Soundproofing<\/h3>\n\n\n\n<p><span translate=\"no\">Seakeeper<\/span> noise has been measured under steady state conditions (no wave load) in <span translate=\"no\">Seakeeper<\/span>\u2018s Engineering Lab and in our Factory Demo Boat. The steady state noise is &lt;72dBC at 1 meter. As the frequencies emitting the highest sound pressures are low (like other marine machinery), it is recommended that the <span translate=\"no\">Seakeeper<\/span> be installed in an enclosed space such as a leaning post \/ seat, bilge, center console, or machinery space. This space can be treated with soundproofing if desired and does not require ventilation for <span translate=\"no\">Seakeeper<\/span> operation.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Seakeeper can only assess installation location regarding its impact on Seakeeper operation and serviceability. Seakeeper cannot determine how the installation location will affect the vessel static or directional stability other than cyclic roll reduction. The Installer is responsible for considering the Seakeeper \u2019s effect on the CG location, trim, overall stability, and performance of the [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":14172,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"manual":[293],"model":[],"document_type":[],"hidden":[],"class_list":["post-14177","page","type-page","status-publish","hentry","manual-seakeeper-3-installation-manual-90378-7"],"acf":[],"_links":{"self":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/14177","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/comments?post=14177"}],"version-history":[{"count":2,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/14177\/revisions"}],"predecessor-version":[{"id":15270,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/14177\/revisions\/15270"}],"up":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/14172"}],"wp:attachment":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/media?parent=14177"}],"wp:term":[{"taxonomy":"manual","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/manual?post=14177"},{"taxonomy":"model","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/model?post=14177"},{"taxonomy":"document_type","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/document_type?post=14177"},{"taxonomy":"hidden","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/hidden?post=14177"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}