{"id":13890,"date":"2023-03-15T09:21:18","date_gmt":"2023-03-15T09:21:18","guid":{"rendered":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-4-5-installation-manual\/6-0-installation-and-start-up-checklist\/6-2-installation-checklist\/"},"modified":"2025-12-03T13:33:56","modified_gmt":"2025-12-03T13:33:56","slug":"6-2-installation-checklist","status":"publish","type":"page","link":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-4-4-5-installation-manual\/6-0-installation-and-start-up-checklist\/6-2-installation-checklist\/","title":{"rendered":"6.2  Installation Checklist"},"content":{"rendered":"\n<h3 class=\"wp-block-heading\">6.2.1  Mechanical Checklist<\/h3>\n\n\n\n<p><img loading=\"lazy\" decoding=\"async\" width=\"25\" height=\"24\" class=\"wp-image-9567\" style=\"width: 25px;\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png 156w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark-150x149.png 150w\" sizes=\"auto, (max-width: 25px) 100vw, 25px\" \/> <span translate=\"no\">Seakeeper<\/span> foundation installed per requirements of Drawing No. 90726 \u2013 <br> <span translate=\"no\">Seakeeper<\/span> 4 &amp; 4.5 Bolt-In Installation Details.<\/p>\n\n\n\n<p>Structure designed to accommodate <span translate=\"no\">Seakeeper<\/span> 4.5 forces, as defined in<br> Drawing 90726 &#8211; <span translate=\"no\">Seakeeper<\/span> 4 &amp; 4.5 Bolt-In Details, with a minimum safety<br> factor of 2.0.<\/p>\n\n\n\n<p>          Foundation is coplanar within 0.06 in. (1.5 mm).<\/p>\n\n\n\n<p><img loading=\"lazy\" decoding=\"async\" width=\"25\" height=\"24\" class=\"wp-image-9567\" style=\"width: 25px;\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png 156w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark-150x149.png 150w\" sizes=\"auto, (max-width: 25px) 100vw, 25px\" \/>  Clearances around <span translate=\"no\">Seakeeper<\/span> meet service and operating specifications<br>        and no obstructions are within the <span translate=\"no\">Seakeeper<\/span> envelope.<\/p>\n\n\n\n<p><img loading=\"lazy\" decoding=\"async\" width=\"25\" height=\"24\" class=\"wp-image-9567\" style=\"width: 25px;\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png 156w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark-150x149.png 150w\" sizes=\"auto, (max-width: 25px) 100vw, 25px\" \/> <span translate=\"no\">Seakeeper<\/span> 4 &amp; 4.5 Bolt-In Kit is installed (P\/N 90804 &#8211; Blind Hole Installation) (P\/N 90805 &#8211; Thru-Hole Installation).<\/p>\n\n\n\n<p><img loading=\"lazy\" decoding=\"async\" width=\"25\" height=\"24\" class=\"wp-image-9567\" style=\"width: 25px;\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png 156w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark-150x149.png 150w\" sizes=\"auto, (max-width: 25px) 100vw, 25px\" \/> Foundation bolts torqued to specification: 155 ft-lbs (210 Nm).<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">6.2.2  Electrical Checklist<\/h3>\n\n\n\n<p><img loading=\"lazy\" decoding=\"async\" width=\"25\" height=\"24\" class=\"wp-image-9567\" style=\"width: 25px;\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png 156w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark-150x149.png 150w\" sizes=\"auto, (max-width: 25px) 100vw, 25px\" \/>  <strong>Ground Cable<\/strong> (Customer Supplied) ground cable connected on both ends.<\/p>\n\n\n\n<p><img loading=\"lazy\" decoding=\"async\" width=\"25\" height=\"24\" class=\"wp-image-9567\" style=\"width: 25px;\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png 156w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark-150x149.png 150w\" sizes=\"auto, (max-width: 25px) 100vw, 25px\" \/>  <strong>12 VDC Control Power Cable<\/strong> (<span translate=\"no\">Seakeeper<\/span> Supplied) <\/p>\n\n\n\n<p>          Connect wire end to 12 VDC power at customer-supplied connection<br>          box or directly to circuit breaker.<\/p>\n\n\n\n<p>          Plug connector of Cable 1 into mating connector on <span translate=\"no\">Seakeeper<\/span> wire<br>          harness (INPUT POWER).<\/p>\n\n\n\n<p><img loading=\"lazy\" decoding=\"async\" width=\"25\" height=\"24\" class=\"wp-image-9567\" style=\"width: 25px;\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png 156w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark-150x149.png 150w\" sizes=\"auto, (max-width: 25px) 100vw, 25px\" \/>  <strong>Seawater Pump Input Power Cable<\/strong> (<span translate=\"no\">Seakeeper<\/span> Supplied)<\/p>\n\n\n\n<p>          Connect wire end to 12 VDC power at customer-supplied connection<br>          box or directly to circuit breaker.<\/p>\n\n\n\n<p>          Plug connector of Cable 9 into mating connector on <span translate=\"no\">Seakeeper<\/span> wire<br>          harness (SW PUMP VDC IN).<\/p>\n\n\n\n<p><img loading=\"lazy\" decoding=\"async\" width=\"25\" height=\"24\" class=\"wp-image-9567\" style=\"width: 25px;\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png 156w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark-150x149.png 150w\" sizes=\"auto, (max-width: 25px) 100vw, 25px\" \/>  <strong>Seawater Pump Output Cable<\/strong> (<span translate=\"no\">Seakeeper<\/span> Supplied)<\/p>\n\n\n\n<p>          Connect Cable 5 from SW PUMP VDC OUT to customer-supplied<br>          12 VDC seawater pump.<br><\/p>\n\n\n\n<p><strong>SEAKEEPER DISPLAY CONNECTION<\/strong><\/p>\n\n\n\n<p><img loading=\"lazy\" decoding=\"async\" width=\"25\" height=\"24\" class=\"wp-image-9567\" style=\"width: 25px;\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png 156w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark-150x149.png 150w\" sizes=\"auto, (max-width: 25px) 100vw, 25px\" \/>  Ensure one of the following display options is installed:<\/p>\n\n\n\n<p>          <strong>Option 1:<\/strong> Compatible MFD (refer to <span translate=\"no\">Seakeeper<\/span> MFD Compatibility<br>          Technical Bulletins)<\/p>\n\n\n\n<p>          <strong>Option 2:<\/strong> <span translate=\"no\">Seakeeper<\/span> 5&#8243; Touch Display (P\/N 90600)<br><\/p>\n\n\n\n<p><strong>NMEA 2000 NETWORK CONENCTION<\/strong><\/p>\n\n\n\n<p><img loading=\"lazy\" decoding=\"async\" width=\"25\" height=\"24\" class=\"wp-image-9567\" style=\"width: 25px;\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png 156w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark-150x149.png 150w\" sizes=\"auto, (max-width: 25px) 100vw, 25px\" \/>  Required GPS signal on NMEA 2000 backbone<\/p>\n\n\n\n<p><img loading=\"lazy\" decoding=\"async\" width=\"25\" height=\"24\" class=\"wp-image-9567\" style=\"width: 25px;\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png 156w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark-150x149.png 150w\" sizes=\"auto, (max-width: 25px) 100vw, 25px\" \/>  Connect <strong>NMEA CAN Cable<\/strong> to ConnectBox NMEA port.<\/p>\n\n\n\n<p><img loading=\"lazy\" decoding=\"async\" width=\"25\" height=\"24\" class=\"wp-image-9567\" style=\"width: 25px;\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png 156w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark-150x149.png 150w\" sizes=\"auto, (max-width: 25px) 100vw, 25px\" \/>  Connect <strong>NMEA CAN Cable<\/strong> to vessel NMEA backbone.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">6.2.3  Cooling Checklist<\/h3>\n\n\n\n<p><img loading=\"lazy\" decoding=\"async\" width=\"25\" height=\"24\" class=\"wp-image-9567\" style=\"width: 25px;\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png 156w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark-150x149.png 150w\" sizes=\"auto, (max-width: 25px) 100vw, 25px\" \/>  Install 12 VDC seawater pump capable of required flow rates<br>        (<span translate=\"no\">Seakeeper<\/span> 4.5 may operate a 24 VDC Seawater Pump).<\/p>\n\n\n\n<p>          Optional seawater pump can be purchased through <span translate=\"no\">Seakeeper<\/span> (P\/N 30331)<\/p>\n\n\n\n<p><img loading=\"lazy\" decoding=\"async\" width=\"25\" height=\"24\" class=\"wp-image-9567\" style=\"width: 25px;\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png 156w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark-150x149.png 150w\" sizes=\"auto, (max-width: 25px) 100vw, 25px\" \/>  Route and connect seawater inlet and outlet hoses per 90802 &#8211; <span translate=\"no\">Seakeeper<\/span> 4 \/ 4.5<br>        Cooling Water Schematic.<\/p>\n\n\n\n<p><img loading=\"lazy\" decoding=\"async\" width=\"25\" height=\"24\" class=\"wp-image-9567\" style=\"width: 25px;\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png 156w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark-150x149.png 150w\" sizes=\"auto, (max-width: 25px) 100vw, 25px\" \/>  Test seawater pump with Seawater Override<\/p>\n\n\n\n<p>Verify 2.5 GPM (9.5 LPM) minimum and 4 GPM (15.1 LPM) maximum flow rate.<\/p>\n\n\n\n<p><img loading=\"lazy\" decoding=\"async\" width=\"25\" height=\"24\" class=\"wp-image-9567\" style=\"width: 25px;\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark.png 156w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Check-mark-150x149.png 150w\" sizes=\"auto, (max-width: 25px) 100vw, 25px\" \/>  Verify coolant level at bottom of filler neck in reservoir.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>6.2.1 Mechanical Checklist Seakeeper foundation installed per requirements of Drawing No. 90726 \u2013 Seakeeper 4 &amp; 4.5 Bolt-In Installation Details. Structure designed to accommodate Seakeeper 4.5 forces, as defined in Drawing 90726 &#8211; Seakeeper 4 &amp; 4.5 Bolt-In Details, with a minimum safety factor of 2.0. Foundation is coplanar within 0.06 in. (1.5 mm). Clearances [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":13840,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"manual":[289],"model":[],"document_type":[],"hidden":[],"class_list":["post-13890","page","type-page","status-publish","hentry","manual-seakeeper-4-4-5-installation-manual"],"acf":[],"_links":{"self":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/13890","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/comments?post=13890"}],"version-history":[{"count":7,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/13890\/revisions"}],"predecessor-version":[{"id":21139,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/13890\/revisions\/21139"}],"up":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/13840"}],"wp:attachment":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/media?parent=13890"}],"wp:term":[{"taxonomy":"manual","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/manual?post=13890"},{"taxonomy":"model","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/model?post=13890"},{"taxonomy":"document_type","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/document_type?post=13890"},{"taxonomy":"hidden","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/hidden?post=13890"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}