{"id":13874,"date":"2023-03-15T09:18:21","date_gmt":"2023-03-15T09:18:21","guid":{"rendered":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-4-5-installation-manual\/4-0-cooling-installation\/4-1-cooling-installation-introduction\/"},"modified":"2025-06-17T17:33:46","modified_gmt":"2025-06-17T17:33:46","slug":"4-1-cooling-installation-introduction","status":"publish","type":"page","link":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-4-4-5-installation-manual\/4-0-cooling-installation\/4-1-cooling-installation-introduction\/","title":{"rendered":"4.1  Cooling Installation Introduction"},"content":{"rendered":"\n<p>The <span translate=\"no\">Seakeeper<\/span> 4 \/ 4.5 is shipped with the cooling circuit filled and ready for use. Only a quick confirmation of glycol level is required.<\/p>\n\n\n\n<p>Reference Documents:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a rel=\"noreferrer noopener\" href=\"https:\/\/www.seakeeper.com\/technical-library\/?type=&amp;product=&amp;search=90696\" target=\"_blank\">90696 &#8211; <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> 4.5 Cable Block Diagram<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.seakeeper.com\/technical-library\/?type=&amp;product=&amp;search=90699\" target=\"_blank\" rel=\"noreferrer noopener\">90699 &#8211; <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> 4 Cable Block Diagram<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.seakeeper.com\/technical-library\/?type=&amp;product=&amp;search=90802\" target=\"_blank\" rel=\"noreferrer noopener\">90802 &#8211; <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> 4 \/ 4.5 Cooling Water Schematic<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.seakeeper.com\/technical-library\/?type=&amp;product=&amp;search=30331\" target=\"_blank\" rel=\"noreferrer noopener\">30331 &#8211; <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> DC Seawater Pump Assembly<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.seakeeper.com\/technical-library\/?type=&amp;product=&amp;search=90191\" target=\"_blank\" rel=\"noreferrer noopener\">TB-90947 &#8211; Seawater Plumbing Best Practices<\/a><\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator is-style-wide\"\/>\n\n\n\n<p>The <span translate=\"no\">Seakeeper<\/span> 4\/4.5 is shipped with the cooling circuit filled and ready for use. The <span translate=\"no\">Seakeeper<\/span> 4\/4.5 requires connection to a raw water pump, referred to as the seawater pump, to cool the closed loop cooling circuit on the unit.\u00a0 The required seawater flow through the <span translate=\"no\">Seakeeper<\/span> 2 heat exchanger is between 2.5 \u2013 4 GPM (9.5 \u2013 15.1 LPM) when the on-demand cooling system requires cooling. Prior to operation, confirmation of glycol level is recommended.<\/p>\n\n\n\n<p><span translate=\"no\">Seakeeper<\/span> offers a compatible self-priming DC Seawater Pump (P\/N 30331) prewired for the <span translate=\"no\">Seakeeper<\/span> 2 Installation and covered under the standard <span translate=\"no\">Seakeeper<\/span> warranty. The pump conforms to the seawater plumbing best practices noted in TB-90947. See Drawing No. 30331, SeaFlo\u00ae Seawater Pump Assembly, and the <span translate=\"no\">Seakeeper<\/span> Options and Accessories Price List for details.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1177\" height=\"848\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/4.5-Cooling-System.png\" alt=\"\" class=\"wp-image-13458\" style=\"width:589px;height:424px\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/4.5-Cooling-System.png 1177w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/4.5-Cooling-System-768x553.png 768w\" sizes=\"auto, (max-width: 1177px) 100vw, 1177px\" \/><figcaption class=\"wp-element-caption\"><strong><em>Figure 1 &#8211; <\/em><\/strong><em><span translate=\"no\">Seakeeper<\/span> 4 and 4.5 Cooling Components<\/em><\/figcaption><\/figure>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>The Seakeeper 4 \/ 4.5 is shipped with the cooling circuit filled and ready for use. Only a quick confirmation of glycol level is required. Reference Documents: The Seakeeper 4\/4.5 is shipped with the cooling circuit filled and ready for use. The Seakeeper 4\/4.5 requires connection to a raw water pump, referred to as the [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":13834,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"manual":[289],"model":[],"document_type":[],"hidden":[],"class_list":["post-13874","page","type-page","status-publish","hentry","manual-seakeeper-4-4-5-installation-manual"],"acf":[],"_links":{"self":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/13874","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/comments?post=13874"}],"version-history":[{"count":7,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/13874\/revisions"}],"predecessor-version":[{"id":20171,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/13874\/revisions\/20171"}],"up":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/13834"}],"wp:attachment":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/media?parent=13874"}],"wp:term":[{"taxonomy":"manual","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/manual?post=13874"},{"taxonomy":"model","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/model?post=13874"},{"taxonomy":"document_type","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/document_type?post=13874"},{"taxonomy":"hidden","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/hidden?post=13874"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}