{"id":12784,"date":"2023-02-28T16:17:43","date_gmt":"2023-02-28T16:17:43","guid":{"rendered":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-26-20hd-installation-manual-90265-7-copy\/start-up\/start-up-instructions\/"},"modified":"2025-03-21T15:45:15","modified_gmt":"2025-03-21T15:45:15","slug":"start-up-instructions","status":"publish","type":"page","link":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-26-installation-manual-90265-8\/start-up\/start-up-instructions\/","title":{"rendered":"5.2  Required Supplies for Seakeeper Installation"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" id=\"block-cc9a261a-6fb8-4cea-b93c-3c7300df6803\" style=\"font-size:25px\">(Not Supplied With the <span translate=\"no\">Seakeeper<\/span>)<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Item<\/th><th>Description<\/th><th>Qty<\/th><th>Installation Manual Reference Section<\/th><th>Other Reference<\/th><th>System<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td>Adhesive and cleaning supplies for bonding to hull<\/td><td><\/td><td><a href=\"https:\/\/manuals.seakeeper.com\/seakeeper-26-installation-manual\/mechanical-installation\/introduction\/\" data-type=\"URL\" data-id=\"https:\/\/manuals.seakeeper.com\/seakeeper-26-installation-manual\/mechanical-installation\/introduction\/\" target=\"_blank\" rel=\"noreferrer noopener\">Mechanical Installation<\/a><\/td><td><\/td><td>Mechanical<\/td><\/tr><tr><td>2<\/td><td>Soundproofing Considerations<\/td><td><\/td><td><a href=\"https:\/\/manuals.seakeeper.com\/seakeeper-26-installation-manual\/mechanical-installation\/selection-of-installation-location\/\" data-type=\"URL\" data-id=\"https:\/\/manuals.seakeeper.com\/seakeeper-26-installation-manual\/mechanical-installation\/selection-of-installation-location\/\" target=\"_blank\" rel=\"noreferrer noopener\">Selection of Installation Location<\/a><\/td><td><\/td><td>Mechanical<\/td><\/tr><tr><td>3<\/td><td>Spreader bar for lifting <span translate=\"no\">Seakeeper<\/span><\/td><td><\/td><td><a href=\"https:\/\/manuals.seakeeper.com\/seakeeper-26-installation-manual\/mechanical-installation\/transport-and-unpacking\/\" data-type=\"URL\" data-id=\"https:\/\/manuals.seakeeper.com\/seakeeper-26-installation-manual\/mechanical-installation\/transport-and-unpacking\/\" target=\"_blank\" rel=\"noreferrer noopener\">Transport and Unpacking<\/a><\/td><td>P\/N 80029<\/td><td>Mechanical<\/td><\/tr><tr><td>4<\/td><td>Circuit Breaker, AC, 2-Pole,<br>20 A<\/td><td>1<\/td><td><a href=\"https:\/\/manuals.seakeeper.com\/seakeeper-26-installation-manual\/electrical-installation\/electrical-equipment-power-connections-2\/\" data-type=\"URL\" data-id=\"https:\/\/manuals.seakeeper.com\/seakeeper-26-installation-manual\/electrical-installation\/electrical-equipment-power-connections-2\/\" target=\"_blank\" rel=\"noreferrer noopener\">Electrical Equipment Power Connections<\/a><\/td><td>Dwg 90310<\/td><td>Electrical<\/td><\/tr><tr><td>5<\/td><td>Circuit Breaker, DC, 1-Pole,<br>10 A<\/td><td>1<\/td><td><a href=\"https:\/\/manuals.seakeeper.com\/seakeeper-26-installation-manual\/electrical-installation\/electrical-equipment-power-connections-2\/\" data-type=\"URL\" data-id=\"https:\/\/manuals.seakeeper.com\/seakeeper-26-installation-manual\/electrical-installation\/electrical-equipment-power-connections-2\/\" target=\"_blank\" rel=\"noreferrer noopener\">Electrical Equipment Power Connections<\/a> <\/td><td>Dwg 90310<\/td><td>Electrical<\/td><\/tr><tr><td>6<\/td><td>M6 terminal lug for grounding <span translate=\"no\">Seakeeper<\/span> at rear brace<\/td><td>1<\/td><td><a href=\"https:\/\/manuals.seakeeper.com\/seakeeper-26-installation-manual\/electrical-installation\/electrical-equipment-ground-connections\/\" data-type=\"URL\" data-id=\"https:\/\/manuals.seakeeper.com\/seakeeper-26-installation-manual\/electrical-installation\/electrical-equipment-ground-connections\/\" target=\"_blank\" rel=\"noreferrer noopener\">Electrical Equipment Ground Connections<\/a><\/td><td><\/td><td>Electrical<\/td><\/tr><tr><td>7<\/td><td>Cable, 10 AWG, for grounding <span translate=\"no\">Seakeeper<\/span> at rear brace to vessel ground <\/td><td>AR<\/td><td><a href=\"https:\/\/manuals.seakeeper.com\/seakeeper-26-installation-manual\/electrical-installation\/electrical-equipment-ground-connections\/\" data-type=\"URL\" data-id=\"https:\/\/manuals.seakeeper.com\/seakeeper-26-installation-manual\/electrical-installation\/electrical-equipment-ground-connections\/\" target=\"_blank\" rel=\"noreferrer noopener\">Electrical Equipment Ground Connections<\/a> <\/td><td>Dwg 90310<\/td><td>Electrical<\/td><\/tr><tr><td>8<\/td><td>Sili-Thane 803 Marine Sealant (or equivalent)<\/td><td>AR<\/td><td><a href=\"https:\/\/manuals.seakeeper.com\/seakeeper-26-installation-manual\/mechanical-installation\/bolt-in-installation\/installation-of-seakeeper\/\" data-type=\"URL\" data-id=\"https:\/\/manuals.seakeeper.com\/seakeeper-26-installation-manual\/mechanical-installation\/bolt-in-installation\/installation-of-seakeeper\/\" target=\"_blank\" rel=\"noreferrer noopener\">Bolt-In Installation, Installation of <span translate=\"no\">Seakeeper<\/span><\/a> and<br><a href=\"https:\/\/manuals.seakeeper.com\/seakeeper-26-installation-manual\/mechanical-installation\/saddle-installation\/installation-of-seakeeper\/\" data-type=\"URL\" data-id=\"https:\/\/manuals.seakeeper.com\/seakeeper-26-installation-manual\/mechanical-installation\/saddle-installation\/installation-of-seakeeper\/\" target=\"_blank\" rel=\"noreferrer noopener\">Saddle Installation, Installation of <span translate=\"no\">Seakeeper<\/span><\/a><\/td><td><\/td><td>Mechanical<\/td><\/tr><tr><td>9<\/td><td>Nickel-based Anti-Seize<\/td><td>AR<\/td><td><a href=\"https:\/\/manuals.seakeeper.com\/seakeeper-26-installation-manual\/mechanical-installation\/bolt-in-installation\/installation-of-seakeeper\/\" data-type=\"URL\" data-id=\"https:\/\/manuals.seakeeper.com\/seakeeper-26-installation-manual\/mechanical-installation\/bolt-in-installation\/installation-of-seakeeper\/\" target=\"_blank\" rel=\"noreferrer noopener\">Bolt-In Installation, Installation of <span translate=\"no\">Seakeeper<\/span><\/a> and<br><a href=\"https:\/\/manuals.seakeeper.com\/seakeeper-26-installation-manual\/mechanical-installation\/saddle-installation\/installation-of-seakeeper\/\" data-type=\"URL\" data-id=\"https:\/\/manuals.seakeeper.com\/seakeeper-26-installation-manual\/mechanical-installation\/saddle-installation\/installation-of-seakeeper\/\" target=\"_blank\" rel=\"noreferrer noopener\">Saddle Installation, Installation of <span translate=\"no\">Seakeeper<\/span><\/a> <\/td><td><\/td><td>Mechanical<\/td><\/tr><tr><td>10<\/td><td>Seawater Pump, 24 VAC<\/td><td>1<\/td><td><a href=\"https:\/\/manuals.seakeeper.com\/seakeeper-26-installation-manual\/electrical-installation\/electrical-equipment-power-connections-2\/\" data-type=\"URL\" data-id=\"https:\/\/manuals.seakeeper.com\/seakeeper-26-installation-manual\/electrical-installation\/electrical-equipment-power-connections-2\/\" target=\"_blank\" rel=\"noreferrer noopener\">Electrical Equipment Power Connections<\/a>  <\/td><td>Dwg 90320<\/td><td>Electrical<\/td><\/tr><tr><td>11<\/td><td>Relay for seawater pump control (Not required if using 230 VAC pump)<\/td><td>1<\/td><td><a href=\"https:\/\/manuals.seakeeper.com\/seakeeper-26-installation-manual\/electrical-installation\/electrical-equipment-power-connections-2\/\" data-type=\"URL\" data-id=\"https:\/\/manuals.seakeeper.com\/seakeeper-26-installation-manual\/electrical-installation\/electrical-equipment-power-connections-2\/\" target=\"_blank\" rel=\"noreferrer noopener\">Electrical Equipment Power Connections<\/a>  <\/td><td><\/td><td>Electrical<\/td><\/tr><tr><td>12<\/td><td>\u00be in. (19 mm) ID seawater hose<\/td><td>AR<\/td><td><a href=\"https:\/\/manuals.seakeeper.com\/seakeeper-26-installation-manual\/cooling-installation\/introduction\/\" data-type=\"URL\" data-id=\"https:\/\/manuals.seakeeper.com\/seakeeper-26-installation-manual\/cooling-installation\/introduction\/\" target=\"_blank\" rel=\"noreferrer noopener\">Cooling Installation<\/a><\/td><td>Dwg 90320<\/td><td>Cooling<\/td><\/tr><tr><td>13<\/td><td>Hose clamps for seawater plumbing to \u00be in. (19 mm) hose barb (2 per hose barb)<\/td><td>4<\/td><td><a href=\"https:\/\/manuals.seakeeper.com\/seakeeper-26-installation-manual\/cooling-installation\/introduction\/\" data-type=\"URL\" data-id=\"https:\/\/manuals.seakeeper.com\/seakeeper-26-installation-manual\/cooling-installation\/introduction\/\" target=\"_blank\" rel=\"noreferrer noopener\">Cooling Installation<\/a> <\/td><td>Dwg 90320<\/td><td>Cooling<\/td><\/tr><tr><td>14<\/td><td>Through-hull fittings (1 high-speed pick-up \/ 1 overboard discharge)<\/td><td>2<\/td><td><a href=\"https:\/\/manuals.seakeeper.com\/seakeeper-26-installation-manual\/cooling-installation\/introduction\/\" data-type=\"URL\" data-id=\"https:\/\/manuals.seakeeper.com\/seakeeper-26-installation-manual\/cooling-installation\/introduction\/\" target=\"_blank\" rel=\"noreferrer noopener\">Cooling Installation<\/a> <\/td><td>Dwg 90320<\/td><td>Cooling<\/td><\/tr><tr><td>15<\/td><td>Seawater strainer<\/td><td>1<\/td><td><a href=\"https:\/\/manuals.seakeeper.com\/seakeeper-26-installation-manual\/cooling-installation\/introduction\/\" data-type=\"URL\" data-id=\"https:\/\/manuals.seakeeper.com\/seakeeper-26-installation-manual\/cooling-installation\/introduction\/\" target=\"_blank\" rel=\"noreferrer noopener\">Cooling Installation<\/a> <\/td><td>Dwg 90320<\/td><td>Cooling<\/td><\/tr><tr><td>16<\/td><td>Seacock valve<\/td><td>1<\/td><td><a href=\"https:\/\/manuals.seakeeper.com\/seakeeper-26-installation-manual\/cooling-installation\/introduction\/\" data-type=\"URL\" data-id=\"https:\/\/manuals.seakeeper.com\/seakeeper-26-installation-manual\/cooling-installation\/introduction\/\" target=\"_blank\" rel=\"noreferrer noopener\">Cooling Installation<\/a> <\/td><td>Dwg 90320<\/td><td>Cooling<\/td><\/tr><tr><td>17<\/td><td>Flow restriction valve (optional)<\/td><td>1<\/td><td><a href=\"https:\/\/manuals.seakeeper.com\/seakeeper-26-installation-manual\/cooling-installation\/introduction\/\" data-type=\"URL\" data-id=\"https:\/\/manuals.seakeeper.com\/seakeeper-26-installation-manual\/cooling-installation\/introduction\/\" target=\"_blank\" rel=\"noreferrer noopener\">Cooling Installation<\/a> <\/td><td>Dwg 90320<\/td><td>Cooling<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\"><strong><br>AR = As Required<br>Dwg = Drawing<\/strong><\/figcaption><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>(Not Supplied With the Seakeeper) Item Description Qty Installation Manual Reference Section Other Reference System 1 Adhesive and cleaning supplies for bonding to hull Mechanical Installation Mechanical 2 Soundproofing Considerations Selection of Installation Location Mechanical 3 Spreader bar for lifting Seakeeper Transport and Unpacking P\/N 80029 Mechanical 4 Circuit Breaker, AC, 2-Pole,20 A 1 Electrical [&hellip;]<\/p>\n","protected":false},"author":9,"featured_media":0,"parent":12780,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"manual":[277],"model":[],"document_type":[],"hidden":[],"class_list":["post-12784","page","type-page","status-publish","hentry","manual-seakeeper-26-installation-manual-90265-8"],"acf":[],"_links":{"self":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/12784","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/comments?post=12784"}],"version-history":[{"count":7,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/12784\/revisions"}],"predecessor-version":[{"id":19847,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/12784\/revisions\/19847"}],"up":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/12780"}],"wp:attachment":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/media?parent=12784"}],"wp:term":[{"taxonomy":"manual","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/manual?post=12784"},{"taxonomy":"model","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/model?post=12784"},{"taxonomy":"document_type","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/document_type?post=12784"},{"taxonomy":"hidden","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/hidden?post=12784"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}