{"id":12758,"date":"2023-02-28T16:17:43","date_gmt":"2023-02-28T16:17:43","guid":{"rendered":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-26-20hd-installation-manual-90265-7-copy\/electrical-installation\/electrical-equipment-power-connections-2\/"},"modified":"2025-03-21T15:42:51","modified_gmt":"2025-03-21T15:42:51","slug":"electrical-equipment-power-connections-2","status":"publish","type":"page","link":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-26-installation-manual-90265-8\/electrical-installation\/electrical-equipment-power-connections-2\/","title":{"rendered":"3.2  Electrical Equipment Power Connections"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" style=\"font-size:25px\">230 VAC Power Source Requirements<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>230 VAC (nominal), 1 Phase, 50\/60 Hz, 20 A<\/li>\n\n\n\n<li>For installations of more than one <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span>, a separate circuit breaker must be used for each <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> Motor Drive Box.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator is-style-wide\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" style=\"font-size:25px\">Drive Box AC Power Input Connection Instructions<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Cable: 3 x 10 AWG (3 x 6 mm<sup>2<\/sup> CSA), 10 ft (3 m) length, <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> supplied pre-installed.<br>\n<ol class=\"wp-block-list\">\n<li>Locate AC Power Input Cable to the Motor Drive Box.<br><br><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"419\" class=\"wp-image-4743\" style=\"width: 600px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/SEAKEEPER-26-Motor-Drive-Box-AC-Power-Input-Output-Cable-Glands.jpg\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SEAKEEPER-26-Motor-Drive-Box-AC-Power-Input-Output-Cable-Glands.jpg 990w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SEAKEEPER-26-Motor-Drive-Box-AC-Power-Input-Output-Cable-Glands-768x537.jpg 768w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><br><em><sub><strong>Figure 2 \u2013<\/strong> Motor Drive Box AC Power Input &amp; Output Cable Glands<\/sub><\/em><br><br><br><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"164\" class=\"wp-image-4239\" style=\"width: 500px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/Cable-2-Wire-Connections-at-AC-Power-Distribution-Panel.jpg\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Cable-2-Wire-Connections-at-AC-Power-Distribution-Panel.jpg 868w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Cable-2-Wire-Connections-at-AC-Power-Distribution-Panel-768x252.jpg 768w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><br><em><sub><strong>Figure 3 \u2013 <\/strong>AC Power Input Cable Wire Connections at AC Power Distribution Panel<\/sub><\/em><\/li>\n\n\n\n<li>Connect 230 VAC wires in AC Power Input Cable to a 20 A, double-pole Circuit Breaker at an AC power distribution panel according to Figure 3 above.<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator is-style-wide\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" style=\"font-size:25px\">Drive Box AC Power Output to Seawater Pump Connection Instructions<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\"><div class=\"wp-block-image\">\n<figure class=\"alignright size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"253\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/warning-icon.jpg\" alt=\"\" class=\"wp-image-1505\" style=\"width:160px;height:100px\"\/><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p class=\"has-vivid-red-color has-text-color\"><br><br><strong><strong>Verify that AC power is OFF to the Drive Box before connecting Seawater Power Cable to a Seawater Pump.<\/strong><\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<ol start=\"1\" class=\"wp-block-list\">\n<li>Cable: 3 x 14 AWG (3 x 2 mm<sup>2<\/sup> CSA), 10 ft (3 m) length, <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> supplied pre-installed.<\/li>\n\n\n\n<li>Pumps rated at 230 VAC, 5 A max., Customer-supplied.<br>\n<ol class=\"wp-block-list\">\n<li>Locate AC Power Output Cable to the Seawater Pump from the Drive Box at the middle of three cable glands. (See Figure 2 above).<br><br><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"159\" class=\"wp-image-4751\" style=\"width: 500px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/SEAKEEPER-26-Cable-5-AC-Output-Power-Cable.jpg\" alt=\"\"><br><em><sub><strong>Figure 4 \u2013<\/strong> AC Seawater Output Power Cable<\/sub><\/em><\/li>\n\n\n\n<li>Connect the 230 VAC wires in AC Seawater Power Cable to a 5 A (maximum), Seawater Pump (approximately 1\/3 horsepower or 250 W) according to Figures 4 and 5.<br><br><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"181\" class=\"wp-image-4756\" style=\"width: 600px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/SEAKEEPER-26-Cable-5-Wire-Connections-to-Seawater-Pump.jpg\" alt=\"\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SEAKEEPER-26-Cable-5-Wire-Connections-to-Seawater-Pump.jpg 858w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SEAKEEPER-26-Cable-5-Wire-Connections-to-Seawater-Pump-768x232.jpg 768w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><br><em><sub><strong>Figure 5 \u2013<\/strong> Seawater Pump Power Cable Wire Connections to Seawater Pump<\/sub><\/em><\/li>\n<\/ol>\n<\/li>\n<\/ol>\n\n\n\n<ol start=\"3\" class=\"wp-block-list\">\n<li>If the customer-supplied Seawater Pump is not rated for 230 VAC, the Seawater Pump Power Cable output may be used to switch a customer-supplied relay.<br>\n<ol class=\"wp-block-list\">\n<li>Locate AC power output to the Seawater Pump from the Drive Box at the middle of three cable glands as shown in Figure 2.<\/li>\n\n\n\n<li>The recommended wiring is shown in Figure 6. Refer to Figure 4 for Seawater Pump Cable wire connections.<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"852\" height=\"507\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/SEAKEEPER-26-Recommended-Wiring-for-Seawater-Pumps-Not-230-VAC.jpg\" alt=\"\" class=\"wp-image-4759\" style=\"width:737px;height:433px\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SEAKEEPER-26-Recommended-Wiring-for-Seawater-Pumps-Not-230-VAC.jpg 852w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SEAKEEPER-26-Recommended-Wiring-for-Seawater-Pumps-Not-230-VAC-768x457.jpg 768w\" sizes=\"auto, (max-width: 852px) 100vw, 852px\" \/><figcaption class=\"wp-element-caption\"><em><strong>Figure 6 \u2013<\/strong> Recommended Wiring for Seawater Pumps Other Than 230 VAC<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\"><div class=\"wp-block-image\">\n<figure class=\"alignright size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"253\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/warning-icon.jpg\" alt=\"\" class=\"wp-image-1505\" style=\"width:160px;height:100px\"\/><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p class=\"has-vivid-red-color has-text-color\"><br><strong>Seawater Power Cable contains live voltage when <span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span> is in operation. Do NOT cut Seawater Power Cable. Do not remove Seawater Power Cable from Drive Box.<\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<ol start=\"4\" class=\"wp-block-list\">\n<li>If Seawater Power Cable is not used, bundle cable and secure to forward brace or other area nearby which will not come in contact with moving parts during <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> operation. Do NOT cut Seawater Power Cable as it contains live voltage when <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> is in operation. <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> ships with Seawater Power Cable permanently sealed at end of cable with protective cap in the event it is not used. Do NOT remove Seawater Power Cable from Drive Box as moisture will be free to enter box through open cable gland and corrode internal electronic components<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator is-style-wide\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" style=\"font-size:25px\">24 VDC Power Source Requirements<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>24 VDC, 10 A<\/li>\n\n\n\n<li>A separate breaker should be used for each <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> control power input.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator is-style-wide\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" style=\"font-size:25px\">DC Power Connection Instructions<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\"><div class=\"wp-block-image\">\n<figure class=\"alignright size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"253\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/warning-icon.jpg\" alt=\"\" class=\"wp-image-1505\" style=\"width:159px;height:100px\"\/><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p class=\"has-vivid-red-color has-text-color\"><strong>Reversing polarity on the DC power input to the <span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span> can result in damaging the electronics in the control system.<\/strong><\/p>\n\n\n\n<p>________________________________________________________<\/p>\n\n\n\n<p class=\"has-vivid-red-color has-text-color\"><strong>When energizing DC power for the first time, if Display does not power up immediately then disconnect and inspect connector polarity.<\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<ol class=\"wp-block-list\">\n<li>24 VDC, 10 A, 2 x 12 AWG (3 x 4 mm<sup>2<\/sup> CSA) customer supplied.<br>\n<ol class=\"wp-block-list\">\n<li>Install <span translate=\"no\"><span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span><\/span> provided DC Power Input Cable, P\/N 20248.<br>\n<ol class=\"wp-block-list\">\n<li>Route DC Power Cable to DC Power Distribution Panel.<\/li>\n\n\n\n<li>Terminate positive (B+, Red) conductor through dedicated over-current protection device (customer supplied) and to +24 VDC. <\/li>\n\n\n\n<li>Terminate negative (B-, Black) conductor to battery negative terminal or negative bus.<\/li>\n<\/ol>\n<\/li>\n\n\n\n<li>Before connecting DC Power Cable to <span translate=\"no\"><span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span><\/span>, check for proper voltage and polarity with a DC multimeter using Figure 7 below.<\/li>\n\n\n\n<li>Connect DC Power Cable to 24 VDC input receptacle on <span translate=\"no\"><span translate=\"no\"><span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span><\/span><\/span>.<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"627\" height=\"447\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/DC-Power-Input-Connector-Contact-Assignments-Front.jpg\" alt=\"\" class=\"wp-image-4255\" style=\"width:290px;height:206px\"\/><figcaption class=\"wp-element-caption\"><em><strong>Figure 7 \u2013 <\/strong>DC Power Input Connector Contact Assignments (front)<\/em><\/figcaption><\/figure>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>230 VAC Power Source Requirements Drive Box AC Power Input Connection Instructions Drive Box AC Power Output to Seawater Pump Connection Instructions Verify that AC power is OFF to the Drive Box before connecting Seawater Power Cable to a Seawater Pump. Seawater Power Cable contains live voltage when Seakeeper is in operation. Do NOT cut [&hellip;]<\/p>\n","protected":false},"author":9,"featured_media":0,"parent":12752,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"manual":[277],"model":[],"document_type":[],"hidden":[],"class_list":["post-12758","page","type-page","status-publish","hentry","manual-seakeeper-26-installation-manual-90265-8"],"acf":[],"_links":{"self":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/12758","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/comments?post=12758"}],"version-history":[{"count":16,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/12758\/revisions"}],"predecessor-version":[{"id":19846,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/12758\/revisions\/19846"}],"up":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/12752"}],"wp:attachment":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/media?parent=12758"}],"wp:term":[{"taxonomy":"manual","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/manual?post=12758"},{"taxonomy":"model","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/model?post=12758"},{"taxonomy":"document_type","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/document_type?post=12758"},{"taxonomy":"hidden","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/hidden?post=12758"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}