{"id":12601,"date":"2023-02-24T11:50:04","date_gmt":"2023-02-24T11:50:04","guid":{"rendered":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-35-30hd-operation-manual-90269-7-copy\/specifications-and-summary\/"},"modified":"2024-01-16T12:34:14","modified_gmt":"2024-01-16T12:34:14","slug":"specifications-and-summary","status":"publish","type":"page","link":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-40-operation-manual-rev-1\/specifications-and-summary\/","title":{"rendered":"7.0  Specifications and Summary"},"content":{"rendered":"\n<figure class=\"wp-block-table\"><table><thead><tr><th><\/th><th><span translate=\"no\">Seakeeper<\/span> 40<\/th><\/tr><\/thead><tbody><tr><td><strong>Rated RPM<\/strong><\/td><td>5,150 RPM<\/td><\/tr><tr><td><strong>Angular Momentum at Rated RPM<\/strong><\/td><td>40,000 N-m-s<\/td><\/tr><tr><td><strong>Anti-Rolling Torque at Rated RPM<\/strong><\/td><td>104,720 N-m<\/td><\/tr><tr><td><strong>Spool-up Time to Rated Speed<\/strong><\/td><td>70 minutes (5,150 RPM)<\/td><\/tr><tr><td><strong>Spool-up Time to Stabilization <\/strong><\/td><td>49 minutes (4,380 RPM)<\/td><\/tr><tr><td><strong>Spool-up Power<\/strong><br>AC Motor<br>DC Control<\/td><td><br>5,000 Watts Max<br>240 Watts<\/td><\/tr><tr><td><strong>Operating Power<\/strong><br>AC Motor (Sea state dependent)<br>DC Control<\/td><td>1,900-4,400 Watts<br>240 Watts<\/td><\/tr><tr><td><strong>Voltage<\/strong><br>AC Input<br>DC Input<\/td><td><br>208-230 VAC (\u00b110%), 50\/60 Hz, Single Phase, 30 A<br>24 VDC @ 15 A (Controls) and 24 VDC @ 20 A (Seawater Pump)<\/td><\/tr><tr><td><strong>Seawater Supply to Heat Exchanger<\/strong><\/td><td>15 GPM (57 LPM) maximum<br>13 GPM (49 LPM) minimum<\/td><\/tr><tr><td><strong>Ambient Air Temperature<\/strong><\/td><td>32\u02da &#8211; 140\u02daF (0 &#8211; 60\u02daC)<\/td><\/tr><tr><td><strong>Weight<\/strong><\/td><td>4,074 lbs (1,848 kg)<\/td><\/tr><tr><td><strong>Envelope Dimensions<\/strong><\/td><td>54.3 L X 55.9 W X 40.6 H (inches)<br>1.38 L x 1.42 W x 1.04 H (meters)<\/td><\/tr><tr><td><strong>Noise Output<\/strong><\/td><td>At full operating RPM, steady state noise measured in the factory at a 1-meter distance measures 72-74 dBC (sound levels may be higher during spool-up).<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"2818\" height=\"2475\" src=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SK40.png\" alt=\"\" class=\"wp-image-12404\" style=\"width:582px;height:auto\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SK40.png 2818w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SK40-768x675.png 768w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SK40-1536x1349.png 1536w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/SK40-2048x1799.png 2048w\" sizes=\"auto, (max-width: 2818px) 100vw, 2818px\" \/><\/figure>\n<\/div>\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p><strong>Arrangement<\/strong><br>The <span translate=\"no\">Seakeeper<\/span> 40 consists of the Flywheel, Enclosure, Foundation, Electronics, Brake, Cooling, and Cover Subsystems.<br><br><strong>Installation Location<br><\/strong>The <span translate=\"no\">Seakeeper<\/span> is a torque device and does not have to be installed in a specific hull location or on the centerline. However, the <span translate=\"no\">Seakeeper<\/span> should <strong>not<\/strong> be installed forward of the longitudinal center of gravity in a planing vessel.<br><br><strong>Mounting Dimensions<br><\/strong>See Drawing No. 90714 \u2013 <span translate=\"no\">Seakeeper<\/span> 40 Bolt-In Installation Details.<br><br><strong>Loads<\/strong><br>The installer is responsible for designing the foundation to which the <span translate=\"no\">Seakeeper<\/span> is attached and for ensuring that this foundation can safely transfer the concentrated <span translate=\"no\">Seakeeper<\/span> loads from the frame to the adjacent hull structure. Loads that the <span translate=\"no\">Seakeeper<\/span> imposes on the hull structure are explained on Drawing No. 90714 \u2013 <span translate=\"no\">Seakeeper<\/span> 40 Bolt-In Installation Details; these loads do NOT include vessel motion accelerations, such as vertical slam loads which can be high for higher speed vessels.<br><br><strong>Cooling<\/strong><br>The <span translate=\"no\">Seakeeper<\/span> bearings, Motor Drive Box, and hydraulic manifold are cooled by a closed water \/ glycol mix cooling loop that incorporates a seawater heat exchanger. The installer is responsible for providing 13 \u2013 15 GPM (49 &#8211; 57 LPM) raw water at ambient sea temperature and a maximum pressure of 20 psi (1.4 bar) to the heat exchanger.<br><br><strong>Electrical<\/strong><br>The installer is responsible for supplying 208-230 VAC, 50\/60 Hz, single phase power on a (30 A for <span translate=\"no\">Seakeeper<\/span> 40) service to the Motor Drive Box, 24 VDC at 15 A service to the <span translate=\"no\">Seakeeper<\/span> Control System, and 24 VDC at 20 A service for the DC Seawater Pump. Separate circuit breakers should be used for each Motor Drive Box in multiple <span translate=\"no\">Seakeeper<\/span> installations. Similarly, separate circuit breakers should be used for each <span translate=\"no\">Seakeeper<\/span> Control System and DC Seawater Pump in multiple <span translate=\"no\">Seakeeper<\/span> installations.<br><br><strong>Operator Controls<br><\/strong>A ConnectBox user interface or a customer-supplied MFD or optional 5&#8243; display is used to start, operate, monitor, and shutdown the <span translate=\"no\">Seakeeper<\/span>.<br><br><strong>Performance<\/strong><br>Reduction of boat roll is a function of the boat\u2019s displacement, transverse metacentric height (GM<sub>T<\/sub>) and hull damping as well as the operating conditions (speed and heading with respect to waves) and sea state. The <span translate=\"no\">Seakeeper<\/span> controller regulates the active hydraulic brake to ensure the <span translate=\"no\">Seakeeper<\/span>\u2019s anti-roll torque is maximized regardless of hull characteristics or operating conditions.<br><br><strong>Alarm and Monitoring<\/strong><br>Sensors, alarms and shutdowns are provided to allow unattended operation. Sensors measure <span translate=\"no\">Seakeeper<\/span> and drive temperatures, vacuum pressure, gimbal angle, brake pressure, and ship motion. The <span translate=\"no\">Seakeeper<\/span> controller sends sensor values and alarm information to the display and also locks the brake and shuts down the motor drive in the event of an alarm condition. <span translate=\"no\">Seakeeper<\/span> operating history during faults or alarms is recorded in the controller\u2019s memory for subsequent recall if service is needed. <span translate=\"no\">Seakeeper<\/span> may access the <span translate=\"no\">Seakeeper<\/span>\u2019s software to gather run hours, bearing loading, and hull slamming information.<br><br><strong>Safety<\/strong><br>The brake automatically locks the <span translate=\"no\">Seakeeper<\/span> so it cannot generate excessive anti-rolling torque loads in the event of a system fault or alarm, loss of electrical power or loss of brake pressure. The brake can be locked from the Display or by shutting off AC and DC power at the supply breakers.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Seakeeper 40 Rated RPM 5,150 RPM Angular Momentum at Rated RPM 40,000 N-m-s Anti-Rolling Torque at Rated RPM 104,720 N-m Spool-up Time to Rated Speed 70 minutes (5,150 RPM) Spool-up Time to Stabilization 49 minutes (4,380 RPM) Spool-up PowerAC MotorDC Control 5,000 Watts Max240 Watts Operating PowerAC Motor (Sea state dependent)DC Control 1,900-4,400 Watts240 Watts [&hellip;]<\/p>\n","protected":false},"author":9,"featured_media":0,"parent":12538,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"manual":[275],"model":[],"document_type":[],"hidden":[],"class_list":["post-12601","page","type-page","status-publish","hentry","manual-seakeeper-40-operation-manual-rev-1"],"acf":[],"_links":{"self":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/12601","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/comments?post=12601"}],"version-history":[{"count":6,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/12601\/revisions"}],"predecessor-version":[{"id":18067,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/12601\/revisions\/18067"}],"up":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/12538"}],"wp:attachment":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/media?parent=12601"}],"wp:term":[{"taxonomy":"manual","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/manual?post=12601"},{"taxonomy":"model","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/model?post=12601"},{"taxonomy":"document_type","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/document_type?post=12601"},{"taxonomy":"hidden","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/hidden?post=12601"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}