{"id":10238,"date":"2022-08-02T18:28:12","date_gmt":"2022-08-02T18:28:12","guid":{"rendered":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-5-6-installation-manual-90402-3-copy\/start-up\/start-up-instructions\/"},"modified":"2023-02-22T17:44:51","modified_gmt":"2023-02-22T17:44:51","slug":"start-up-instructions","status":"publish","type":"page","link":"https:\/\/manuals.seakeeper.com\/seakeeper\/seakeeper-5-6-installation-manual-rev4\/start-up\/start-up-instructions\/","title":{"rendered":"5.2   Start Up Instructions"},"content":{"rendered":"\n<ol class=\"wp-block-list\">\n<li>Energize 12 VDC supply at the customer-supplied electrical disconnect.<\/li>\n\n\n\n<li>Supply 110-230 VAC to Motor Drive Box at customer-supplied electrical disconnect.<\/li>\n\n\n\n<li>Turn on the boat\u2019s DC dedicated circuit breaker that supplies power to the DC seawater pump.<\/li>\n\n\n\n<li>With system powered up check the display for any ALARMS. If there are any ALARMS present they must be corrected first.<\/li>\n\n\n\n<li>Press the <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> ON\/OFF Button on Display. <img loading=\"lazy\" decoding=\"async\" width=\"50\" height=\"32\" class=\"wp-image-1898\" style=\"width: 50px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/Seakeeper_Power_On_Button.jpg\" alt=\"\"> The progress bar will appear and indicate how soon the <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> will be available for stabilization. When the <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> is initialized and up to minimum operating speed the STABILIZE button <img loading=\"lazy\" decoding=\"async\" width=\"50\" height=\"33\" class=\"wp-image-2198\" style=\"width: 50px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/SEAKEEPER-2-Stabilize-Button.jpg\" alt=\"\"> will appear. At this point, the <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> is available for stabilization.<\/li>\n<\/ol>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"962\" height=\"538\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/Home-Screen-during-spool-up-sequence.jpg\" alt=\"\" class=\"wp-image-1627\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Home-Screen-during-spool-up-sequence.jpg 962w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Home-Screen-during-spool-up-sequence-768x430.jpg 768w\" sizes=\"auto, (max-width: 962px) 100vw, 962px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"961\" height=\"537\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/Home-Screen-with-available-stabilization.jpg\" alt=\"\" class=\"wp-image-1628\" srcset=\"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Home-Screen-with-available-stabilization.jpg 961w, https:\/\/manuals.seakeeper.com\/seakeeper\/wp-content\/uploads\/Home-Screen-with-available-stabilization-768x429.jpg 768w\" sizes=\"auto, (max-width: 961px) 100vw, 961px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<ol class=\"wp-block-list\" start=\"6\">\n<li>The seawater pump will operate for two minutes after the ON\/OFF button on the display was depressed. After that the seawater pump output is turned on and off based on the temperature of the <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span>. Confirm pump operation and flow rate, if practical. Required flow is 2.5 GPM (9.5 LPM) minimum and 8 GPM (30 LPM) maximum.<\/li>\n\n\n\n<li>Verify that there are no ALARMS present. If an ALARM is present it will be displayed.<\/li>\n\n\n\n<li>When the <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> reaches its maximum operating speed where maximum stabilization is available, the progress bar will disappear and the <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> is available for maximum stabilization. Press the STABILIZE button. <img loading=\"lazy\" decoding=\"async\" width=\"50\" height=\"33\" class=\"wp-image-2198\" style=\"width: 50px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/SEAKEEPER-2-Stabilize-Button.jpg\" alt=\"\"> The button will turn blue indicating that the <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> is stabilizing the roll motion.<\/li>\n<\/ol>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"438\" height=\"239\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/SEAKEEPER-2-Ready-to-Stabilize-Screen.jpg\" alt=\"\" class=\"wp-image-2200\"\/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/SEAKEEPER-2-Stabilizing-Screen.jpg\" alt=\"\" class=\"wp-image-2201\" width=\"382\" height=\"212\"\/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<ol class=\"wp-block-list\" start=\"9\">\n<li>Verify that there are no ALARMS. If an ALARM is present it will be displayed.<\/li>\n\n\n\n<li>Press the STABILIZE Button <img loading=\"lazy\" decoding=\"async\" width=\"50\" height=\"34\" class=\"wp-image-2202\" style=\"width: 50px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/SEAKEEPER-2-Stabilizing-Button.jpg\" alt=\"\"> to turn stabilization off. Then press the <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> ON\/OFF Button <img loading=\"lazy\" decoding=\"async\" width=\"50\" height=\"34\" class=\"wp-image-1897\" style=\"width: 50px;\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/Seakeeper_Power_Off_Button.jpg\" alt=\"\"> to power the <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> down.<\/li>\n\n\n\n<li>During normal operation, the <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> should be stopped when stabilization is no longer required. This maximizes long term life as it allows the <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> to start the coast down cycle before cooling is shutoff. Once the vessel is secured in the slip and the crew has shut down the generator and engines, the AC and DC breakers that control the <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> should be switched to the OFF position. The <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> will continue to spool down to 0 RPM. No cooling is required during this time. Note the <span translate=\"no\"><span translate=\"no\">Seakeeper<\/span><\/span> 6 will take 4+ hours to coast down to 0 RPM from full speed. When the flywheel has stopped the service screen will indicate 0 RPM.<\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/manuals.seakeeper.com\/wp-content\/uploads\/SEAKEEPER-2-Cooling-Screen.jpg\" alt=\"\" class=\"wp-image-2203\" width=\"433\" height=\"242\"\/><\/figure>\n<\/div>","protected":false},"excerpt":{"rendered":"","protected":false},"author":9,"featured_media":0,"parent":10234,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"manual":[259],"model":[],"document_type":[],"hidden":[],"class_list":["post-10238","page","type-page","status-publish","hentry","manual-seakeeper-5-6-installation-manual-rev4"],"acf":[],"_links":{"self":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/10238","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/comments?post=10238"}],"version-history":[{"count":5,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/10238\/revisions"}],"predecessor-version":[{"id":12090,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/10238\/revisions\/12090"}],"up":[{"embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/pages\/10234"}],"wp:attachment":[{"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/media?parent=10238"}],"wp:term":[{"taxonomy":"manual","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/manual?post=10238"},{"taxonomy":"model","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/model?post=10238"},{"taxonomy":"document_type","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/document_type?post=10238"},{"taxonomy":"hidden","embeddable":true,"href":"https:\/\/manuals.seakeeper.com\/seakeeper\/wp-json\/wp\/v2\/hidden?post=10238"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}