Seakeeper 6 Installation Manual (90402-6) 6-254-8146 to Current
4.1 Cooling Installation Introduction
The Seakeeper 6 is shipped with the cooling circuit filled and ready for use. Only a quick confirmation of glycol level is required.
Reference Documents & Drawings:
- 30331 – Seakeeper DC Seawater Pump Assembly
- 90396 – Seakeeper 6 Cable Block Diagram
- 90397 – Seakeeper 6 Cooling Water Schematic
- TB-90191 – Seawater Cooling Pump Recommendations
- TB-90947 – Seawater Plumbing Best Practices
The Seakeeper 6 is shipped with the glycol cooling circuit filled and ready for use. The Seakeeper 6 requires connection to a raw water pump, referred to as the seawater pump, to cool the closed loop cooling circuit on the unit. The required seawater flow through the Seakeeper 6 heat exchanger is between 2.5 – 5 GPM (9.5 – 18.9 LPM) when the on-demand cooling system requires cooling. Prior to operation, confirmation of glycol level is recommended.
Seakeeper offers a compatible self-priming DC Seawater Pump (P/N 30331) prewired for the Seakeeper 6 Installation and covered under the standard Seakeeper warranty. The pump conforms to the seawater plumbing best practices noted in TB-90947. Refer to Drawing No. 30331, SeaFlo® Seawater Pump Assembly, and the Seakeeper Options and Accessories Price List for details.